Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures A randomized controlled trial

被引:9
|
作者
Alzahem, Abdulrahman M. [1 ]
Aqil, Mansoor [2 ]
Alzahrani, Tariq A. [2 ]
Aljazaeri, Ayman H. [1 ]
机构
[1] King Saud Univ, Coll Med, King Saud Univ Med City, Dept Pediat Surg, Riyadh, Saudi Arabia
[2] King Saud Univ, Coll Med, King Saud Univ Med City, Dept Anesthesiol, Riyadh, Saudi Arabia
关键词
SUPRAGLOTTIC AIRWAY; ANESTHETIZED PATIENTS; INTRAOCULAR-PRESSURE; VENTILATED CHILDREN; PEDIATRIC-PATIENTS; COHORT EVALUATION; SCORING SYSTEM; INSERTION; LMA-CLASSIC(TM); PERFORMANCE;
D O I
10.15537/smj.2017.5.17960
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare the efficacy and performance of the pediatric Ambu AuraOnce (Ambu AO) mask (Ambu, Copenhagen, Denmark) and i-gel mask (Intersurgical Ltd., Wokingham, United Kingdom). Methods: From May 2015 to September 2016, 112 patients, 0-14 years old, underwent elective surgery at a tertiary university hospital (Riyadh, Saudi Arabia). They were randomly assigned to the Ambu AO or i-gel group. Three groups underwent a subgroup analysis: <= 5 kg (group 1), 5.1-10.0 kg (group 2), and >10 kg (group 3). Results: The oropharyngeal leak pressure was significantly higher for the i-gel (25.4 +/- 4.1 cm H2O) than for the Ambu AO (22.5 +/- 3.9 cm H2O, p<0.001). The Ambu AO had a slightly higher ease of insertion compared to the i-gel (100% versus 94%, p=0.08) and required less manipulation (2% versus 11%, p=0.07). The Ambu AO and i-gel showed non-significant differences in performance between weight groups. There were statistically significant differences for higher leak pressure in group 2 (p=0.01) and group 3 (p=0.002) in favor of the i-gel, and for less manipulation in the Ambu AO in group 1 (p=0.04). Fiberoptic viewing was superior in group 2 for the i-gel (p=0.03) and in group 3 for the Ambu AO (p=0.02). Conclusion: Both devices demonstrated equally good performance with low morbidity. The Ambu AO had a statistical tendency towards easier insertion and less manipulation. Confirming this finding will require large scale trials.
引用
收藏
页码:482 / 490
页数:9
相关论文
共 50 条
  • [21] A comparison of fibreoptic-guided tracheal intubation through the Ambu®Aura-i™, the intubating laryngeal mask airway and the i-gel™: a manikin study
    de Lloyd, L. J.
    Subash, F.
    Wilkes, A. R.
    Hodzovic, I.
    ANAESTHESIA, 2015, 70 (05) : 591 - 597
  • [22] Effect of Oral Care Solution on Sore Throat After I-Gel Laryngeal Mask General Anesthesia: A Randomized Controlled Trial
    Zhang, Yan
    Meng, Wenjun
    Hu, Chengwen
    Dong, Meirong
    Chu, Youqun
    Kang, Fang
    Li, Juan
    Chen, Xia
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2023, 19 : 929 - 936
  • [23] Desflurane versus sevoflurane in pediatric anesthesia with a laryngeal mask airway A randomized controlled trial
    Kim, Eun-Hee
    Song, In-Kyung
    Lee, Ji-Hyun
    Kim, Hee-Soo
    Kim, Hyun-Chang
    Yoon, Soo-Hyuk
    Jang, Young-Eun
    Kim, Jin-Tae
    MEDICINE, 2017, 96 (35)
  • [24] Comparison of the clinical performance of airway management with the i-gel® and laryngeal mask airway Supreme™ in geriatric patients: a prospective and randomized study
    In, Chi Bum
    Cho, Sung-Ae
    Lee, Seok-Jin
    Sung, Tae-Yun
    Cho, Choon-Kyu
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2019, 72 (01) : 39 - 46
  • [25] Comparison between I-Gel and Classic Laryngeal Mask Airway for Airway Management of Patients with Anticipated Difficult Airway: A Randomised Clinical Trial
    Raman, Rajesh
    Gautam, Shefali
    Sonkar, Suraj
    Prabha, Rati
    Alam, Sharif
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (10) : UC10 - UC13
  • [26] Comparison of Frequency of Complications of i-Gel and Laryngeal Mask Airway Supreme™ in Laparoscopic Cholecystectomy
    Ali, Kashif
    Kumar, Ravi
    Ali, Abid
    Ali, Pervaiz
    Alam, M. Aneeque
    Kumar, Kelash
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (12): : 3180 - 3182
  • [27] Comparison of the I-gel Laryngeal Mask Airway With the LMA-Supreme for Airway Management in Patients Undergoing Elective Lumbar Vertebral Surgery
    Kang, Fang
    Li, Juan
    Chai, XiaoQing
    Yu, JinGui
    Zhang, HuaMing
    Tang, ChaoLiang
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2015, 27 (01) : 37 - 41
  • [28] Comparison of Proseal Laryngeal Mask Airway with the I-Gel Supraglottic Airway During the Bailey Manoeuvre in Adult Patients Undergoing Elective Surgery
    Kalra, Nishant
    Gupta, Akhilesh
    Sood, Rajesh
    Kaur, Mohandeep
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (02) : 107 - 113
  • [29] Comparison of Gastric Insufflation Volume Between Ambu AuraGain and ProSeal Laryngeal Mask Airway Using Ultrasonography in Patients Undergoing General Anesthesia: A Randomized Controlled Trial
    Gunasekaran, Adethen
    Govindaraj, Kirthiha
    Gupta, Suman Lata
    Vinayagam, Stalin
    Mishra, Sandeep Kumar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (08)
  • [30] REMIFENTANIL REQUIREMENT FOR CLASSIC™, FASTRACH™ AND I-GEL™ LARYNGEAL MASK AIRWAY INSERTION WITH TARGET-CONTROLLED PROPOFOL INFUSION
    Can, Ozlem S.
    Ozcelik, Menekse
    Guclu, Cigdem Y.
    Oztuna, Derya
    Alanoglu, Zekeriyya
    Kecik, Yuksel
    ACTA MEDICA MEDITERRANEA, 2013, 29 (04): : 639 - 646