Improvement of Dynamic Behavior of Shunt Active Power Filter Using Fuzzy Instantaneous Power Theory

被引:30
|
作者
Eskandarian, Nasser [1 ]
Beromi, Yousef Alinejad [1 ]
Farhangi, Shahrokh [2 ]
机构
[1] Semnan Univ, Dept Elect & Comp Engn, Semnan, Iran
[2] Univ Tehran, Coll Engn, Sch ECE, Tehran, Iran
关键词
Fuzzy instantaneous power (FIP) theory; Fuzzy logic controller; p-q theory; Time-varying harmonic;
D O I
10.6113/JPE.2014.14.6.1303
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dynamic behavior of the harmonic detection part of an active power filter (APF) has an essential role in filter compensation performances during transient conditions. Instantaneous power (p-q) theory is extensively used to design harmonic detectors for active filters. Large overshoot of p-q theory method deteriorates filter response at a large and rapid load change. In this study the harmonic estimation of an APF during transient conditions for balanced three-phase nonlinear loads is conducted. A novel fuzzy instantaneous power (FIP) theory is proposed to improve conventional p-q theory dynamic performances during transient conditions to adapt automatically to any random and rapid nonlinear load change. Adding fuzzy rules in p-q theory improves the decomposition of the alternating current components of active and reactive power signals and develops correct reference during rapid and random current variation. Modifying p-q theory internal high-pass filter performance using fuzzy rules without any drawback is a prospect. In the simulated system using MATLAB/SIMULINK, the shunt active filter is connected to a rapidly time-varying nonlinear load. The harmonic detection parts of the shunt active filter are developed for FIP theory-based and p-q theory-based algorithms The harmonic detector hardware is also developed using the TMS320F28335 digital signal processor and connected to a laboratory nonlinear load. The software is developed for FIP theory-based and p-q theory-based algorithms. The simulation and experimental tests results verify the ability of the new technique in harmonic detection of rapid changing nonlinear loads.
引用
收藏
页码:1303 / 1313
页数:11
相关论文
共 50 条
  • [1] A Three Phase Shunt Active Power Filter Based on Instantaneous Reactive Power Theory
    Prabhu, Yogesh S.
    Dharme, A. A.
    Talange, D. B.
    2014 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2014,
  • [2] Fuzzy Logic Control of Shunt Active Power Filter for Power Quality Improvement
    Anjana, S.
    Maya, P.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SOFT COMPUTING SYSTEMS, ICSCS 2015, VOL 1, 2016, 397 : 975 - 985
  • [3] Design, Simulation and Analysis of Shunt Active Power Filter using Instantaneous Reactive Power Topology
    Srivastava, Gaurava Deep
    Kulkarni, Rajendrakumar D.
    2017 INTERNATIONAL CONFERENCE ON NASCENT TECHNOLOGIES IN ENGINEERING (ICNTE-2017), 2017,
  • [4] Implementation of Fuzzy Logic in shunt Active Power Filter for Renewable Power Generation System
    Roseline, J. Femila
    Sahoo, Nikhil Kumar
    Abhinav, Ayush
    2016 Second International Conference on Science Technology Engineering and Management (ICONSTEM), 2016, : 451 - 456
  • [5] Performance Improvement of Cycloconverter Fed Induction Machine Using Shunt Active Power Filter
    Goyal, Vishnu
    Wadhawani, Sulochana
    INTELLIGENT COMPUTING TECHNIQUES FOR SMART ENERGY SYSTEMS, 2020, 607 : 769 - 780
  • [6] Fuzzy Logic Controlled Three-Phase Three-Wired Shunt Active Power Filter for Power Quality Improvement
    Gupta, N.
    Singh, S. P.
    Dubey, S. P.
    Palwalia, D. K.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (03): : 1118 - 1129
  • [7] Performance Improvement of Shunt Active power filter with Combined Control Technique
    Puhan, Pratap Sekhar
    Ray, Pravat Kumar
    Panda, Gayadhar
    2017 INTERNATIONAL CONFERENCE ON EMERGING TRENDS & INNOVATION IN ICT (ICEI), 2017, : 56 - 61
  • [8] PI and fuzzy logic controllers for shunt active power filter - A report
    Karuppanan, P.
    Mahapatra, Kamala Kanta
    ISA TRANSACTIONS, 2012, 51 (01) : 163 - 169
  • [9] A Fuzzy Controlled Shunt Active Power Filter for Reducing Current Harmonics and Reactive Power Compensation
    Das Gupta, Udayan
    Das, Palash
    Hoque, Md. Ahsanul
    2ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION COMMUNICATION TECHNOLOGY (ICEEICT 2015), 2015,
  • [10] Power Quality Factor Improvement using Shunt Active Power Line Conditioner
    Nagarjuna, Maravathu
    Panda, P. C.
    Sandeep, Azmera