Handheld scanning probes for Optical Coherence Tomography: Developments, applications and perspectives

被引:7
作者
Duma, V. -F. [1 ,2 ,3 ]
Demian, D. [1 ]
Sinescu, C. [4 ]
Cernat, R. [5 ]
Dobre, G. [5 ]
Negrutiu, M. L. [4 ]
Topala, F. I. [4 ]
Hutiu, Gh. [1 ]
Bradu, A. [5 ]
Podoleanu, A. Gh. [5 ]
机构
[1] Aurel Vlaicu Univ Arad, Optomechatron Grp 3OM, 77 Revolutiei Ave, Arad 310130, Romania
[2] Polytech Univ Timisoara, Doctoral Sch, 1 Mihai Viteazu Ave, Timisoara 300222, Romania
[3] West Univ Timisoara, Fac Phys, 4 Vasile Parvan Ave, Timisoara 300223, Romania
[4] Victor Babes Med & Pharm Univ Timisoara, Fac Med Dent, 2A Eftimie Murgu Pl, Timisoara 300070, Romania
[5] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
来源
HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES | 2016年 / 9670卷
关键词
handheld probes; scanning systems; galvanometers; biomedical imaging; Optical Coherence Tomography; optical design; optomechanics; dentistry; SWEPT SOURCE; OCT; PATTERNS; MIRROR;
D O I
10.1117/12.2178590
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
We present the handheld scanning probes that we have recently developed in our current project for biomedical imaging in general and for Optical Coherence Tomography (OCT) in particular. OCT is an established, but dynamic imagistic technique based on laser interferometry, which offers micrometer resolutions and millimeters penetration depths. With regard to existing devices, the newly developed handheld probes are simple, light and relatively low cost. Their design is described in detail to allow for the reproduction in any lab, including for educational purposes. Two probes are constructed almost entirely from off-the-shelf components, while a third, final variant is constructed with dedicated components, in an ergonomic design. The handheld probes have uni-dimensional (1D) galvanometer scanners therefore they achieve transversal sections through the biological sample investigated - in contrast to handheld probes equipped with bi-dimensional (2D) scanners that can also achieve volumetric (3D) reconstructions of the samples. These latter handheld probes are therefore also discussed, as well as the possibility to equip them with galvanometer 2D scanners or with Risley prisms. For galvanometer scanners the optimal scanning functions studied in a series of previous works are pointed out; these functions offer a higher temporal efficiency/duty cycle of the scanning process, as well as artifact-free OCT images. The testing of the handheld scanning probes in dental applications is presented, for metal ceramic prosthesis and for teeth.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Cirrus High-definition Optical Coherence Tomography Versus Spectral Optical Coherence Tomography/Scanning Laser Ophthalmoscopy in the Diagnosis of Glaucoma
    Koh, Kyung Min
    Jin, Sunyoung
    Hwang, Young Hoon
    CURRENT EYE RESEARCH, 2014, 39 (01) : 62 - 68
  • [42] Handheld optical coherence tomography for clinical assessment of dental plaque and gingiva
    Won, Jungeun
    Huang, Pin-Chieh
    Spillman, Darold R., Jr.
    Chaney, Eric J.
    Adam, Ralf
    Klukowska, Malgorzata
    Barkalifa, Ronit
    Boppart, Stephen A.
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (11)
  • [43] The Use of Handheld Optical Coherence Tomography in Urban Community Eye Screening
    Lin, James
    Patel, Priya
    Szirth, Ben
    Khouri, Albert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [44] New developments in optical coherence tomography imaging for glaucoma
    Mwanza, Jean-Claude
    Budenz, Donald L.
    CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (02) : 121 - 129
  • [45] Recent developments in the use of optical coherence tomography for glaucoma
    Vazquez, Luis E.
    Bye, Amanda
    Aref, Ahmad A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2021, 32 (02) : 98 - 104
  • [46] Handheld line-field confocal optical coherence tomography for dermatology
    Ogien, Jonas
    Levecq, Olivier
    Cazalas, Maxime
    Suppa, Mariano
    del Marmol, Veronique
    Malvehy, Josep
    Cinotti, Elisa
    Rubegni, Pietro
    Perrot, Jean-Luc
    Dubois, Arnaud
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2020, 2020, 11211
  • [47] Swept source optical coherence tomography based on scanning fiber probe
    Wu, Tong
    Ding, Zhihua
    Wang, Kai
    Xu, Lei
    Chen, Minghui
    Wang, Chuan
    Guangxue Xuebao/Acta Optica Sinica, 2009, 29 (SUPPL.): : 37 - 41
  • [48] Pencil-beam scanning catheter for intracoronary optical coherence tomography
    Kang, Jiqiang
    Zhu, Rui
    Sun, Yunxu
    Li, Jianan
    Wong, Kenneth K. Y.
    OPTO-ELECTRONIC ADVANCES, 2022, 5 (03)
  • [49] Multimodal ophthalmic imaging using spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography
    El-Haddad, Mohamed T.
    Malone, Joseph D.
    Li, Jianwei D.
    Bozic, Ivan
    Arquitola, Amber M.
    Joos, Karen M.
    Patel, Shriji N.
    Tao, Yuankai K.
    BIOSENSING AND NANOMEDICINE X, 2017, 10352
  • [50] Importance of Optical Coherence Tomography and Optical Coherence Tomography Angiography in the Imaging and Differentiation of Choroidal Melanoma: A Review
    Obuchowska, Iwona
    Konopinska, Joanna
    CANCERS, 2022, 14 (14)