共 50 条
Iatrogenic Tracheal Rupture during Intubation with a Double-Lumen Tube
被引:8
|作者:
Tezel, C.
[1
]
Okur, E.
[1
]
Baysungur, V.
[1
]
机构:
[1] Sureyyapasa Chest Dis & Thorac Surg Teaching Hosp, Dept Thorac Surg, TR-34744 Istanbul, Turkey
来源:
THORACIC AND CARDIOVASCULAR SURGEON
|
2010年
/
58卷
/
01期
关键词:
Thoracic surgery;
tracheal rupture;
double-lumen tube;
MANAGEMENT;
INJURY;
D O I:
10.1055/s-0029-1186150
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Iatrogenic tracheal rupture after intubation with a double-lumen endotracheal tube is rare. An endobronchial tube positioning guide stylet, which is generally used during intubations with a double-lumen tube, may tear the trachea. A 76-year-old patient with right upper lobe carcinoma was scheduled for video-thoracoscopic lobectomy. Mediastinal lymph node dissection was performed after a right upper lobectomy. When the mediastinal pleura in the right paratracheal region were opened, a tracheal cuff was noticed in the mediastinum. The tear in the membranous part of the trachea was repaired. Use of stylets during intubation may cause tracheal injury. To prevent such an injury, the stylet should be withdrawn after the tip of the tube has passed through the vocal cords.
引用
收藏
页码:54 / U4
页数:3
相关论文