Continuous Monitoring of Blood Pressure Using a Wrist-Worn Cuffless Device

被引:12
|
作者
Sayer, Gabriel [1 ]
Piper, Greta [2 ]
Vorovich, Esther [3 ]
Raikhelkar, Jayant [1 ]
Kim, Gene H. [4 ]
Rodgers, Daniel [4 ]
Shimbo, Daichi [1 ]
Uriel, Nir [1 ]
机构
[1] Columbia Univ, Irving Med Ctr, Dept Med, New York, NY 10027 USA
[2] NYU Langone Hlth, Dept Surg, New York, NY USA
[3] Northwestern Univ, Div Cardiol, Chicago, IL 60611 USA
[4] Univ Chicago, Med Ctr, Sect Cardiol, Dept Med, Chicago, IL 60637 USA
关键词
blood pressure; blood pressure measurement; monitoring; cardiovascular disease; hypertension; remote monitoring; TASK-FORCE;
D O I
10.1093/ajh/hpac020
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND Measuring an accurate blood pressure (BP) in ambulatory patients is critical for therapeutic decisions. An accurate noninvasive device that measures BP continuously could provide a more comprehensive assessment of BP. The aim of this study was to determine whether the LiveOne device, a cuffless wristband that provides continuous BP measurements, is accurate in comparison to an invasive arterial line (A-line). METHODS We enrolled hospitalized patients and healthy volunteers in this multicenter study. All patients had an invasive A-line. Waveforms were simultaneously downloaded from the A-line and LiveOne device. The primary outcome was the correlation between the LiveOne device and the A-line for systolic BP (SBP) and diastolic BP (DBP). RESULTS Thirty-four patients with 233 measurement periods were included. Mean age was 60.7 +/- 15.2 years, and 15 (44%) were female. The correlation for SBP was 0.91 and for DBP was 0.85. The mean band error was 0.0 +/- 6.9 mm Hg for SBP and 1.2 +/- 5.7 mm Hg for DBP. The mean absolute error was 8.2 +/- 5.8 mm Hg for SBP and 6.4 +/- 3.9 mm Hg for DBP. For SBP, 98% of LiveOne measurements were within 15 mm Hg and for DBP, 92% of LiveOne measurements were within 10 mm Hg. CONCLUSIONS The LiveOne device provides continuous, noninvasive BP measurements that are accurate in comparison to A-line measurements. The portability and unobtrusive nature of this device and the ability to provide continuous BP measurements may offer advantages over currently available BP monitors.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 50 条
  • [31] Accuracy of 24-hour ambulatory blood pressure monitoring by a novel cuffless device in clinical practice
    Krisai, Philipp
    Vischer, Annina Salome
    Kilian, Leo
    Meienberg, Andrea
    Mayr, Michael
    Burkard, Thilo
    HEART, 2019, 105 (05) : 399 - +
  • [32] Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring
    Hosanee, Manish
    Chan, Gabriel
    Welykholowa, Kaylie
    Cooper, Rachel
    Kyriacou, Panayiotis A.
    Zheng, Dingchang
    Allen, John
    Abbott, Derek
    Menon, Carlo
    Lovell, Nigel H.
    Howard, Newton
    Chan, Wee-Shian
    Lim, Kenneth
    Fletcher, Richard
    Ward, Rabab
    Elgendi, Mohamed
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)
  • [33] Twenty-Four-Hour Ambulatory Blood Pressure Measurement Using a Novel Noninvasive, Cuffless, Wireless Device
    Nachman, Dean
    Gilan, Adi
    Goldstein, Nir
    Constantini, Keren
    Littman, Romi
    Eisenkraft, Arik
    Grossman, Ehud
    Gepner, Yftach
    AMERICAN JOURNAL OF HYPERTENSION, 2021, 34 (11) : 1171 - 1180
  • [34] Optical microfiber intelligent watchband for cuffless blood pressure monitoring
    Chen, Jiaqi
    Zhang, Yue
    Liu, Bin
    Liu, Juan
    Yang, Hong
    Hu, Yingying
    Fu, Yue
    Wu, Qiang
    SENSORS AND ACTUATORS A-PHYSICAL, 2025, 386
  • [35] Estimation of Physical Activity Intensity in Spinal Cord Injury Using a Wrist-Worn ActiGraph Monitor
    Veerubhotla, Akhila
    Hong, EunKyoung
    Knezevic, Steven
    Spungen, Ann
    Ding, Dan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2020, 101 (09): : 1563 - 1569
  • [36] Comparison of cuff-based and cuffless continuous blood pressure measurements in children and adolescents
    Zachwieja, Jacek
    Neyman-Bartkowiak, Anna
    Rabiega, Alina
    Wojciechowska, Marta
    Barabasz, Malgorzata
    Musielak, Anna
    Silska-Dittmar, Magdalena
    Ostalska-Nowicka, Danuta
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2020, 42 (06) : 512 - 518
  • [37] CONTINUOUS WRIST BLOOD PRESSURE MEASUREMENT WITH ULTRASOUND
    Weber, S.
    Scharfschwerdt, P.
    Seel, T.
    Schauer, T.
    Kertzscher, U.
    Affeld, K.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [38] Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals
    Peng, Rong-Chao
    Yan, Wen-Rong
    Zhang, Ning-Ling
    Lin, Wan-Hua
    Zhou, Xiao-Lin
    Zhang, Yuan-Ting
    SENSORS, 2015, 15 (09) : 23653 - 23666
  • [39] Development of continuous cuffless blood pressure prediction platform using enhanced 1-D SENet-LSTM
    Zhang, Gengjia
    Choi, Daegil
    Jung, Jaehyo
    EXPERT SYSTEMS WITH APPLICATIONS, 2024, 242
  • [40] A Continuous Cuffless Blood Pressure Estimation Using Tree-Based Pipeline Optimization Tool
    Fati, Suliman Mohamed
    Muneer, Amgad
    Akbar, Nur Arifin
    Taib, Shakirah Mohd
    SYMMETRY-BASEL, 2021, 13 (04):