Continuous Monitoring of Blood Pressure Using a Wrist-Worn Cuffless Device

被引:12
|
作者
Sayer, Gabriel [1 ]
Piper, Greta [2 ]
Vorovich, Esther [3 ]
Raikhelkar, Jayant [1 ]
Kim, Gene H. [4 ]
Rodgers, Daniel [4 ]
Shimbo, Daichi [1 ]
Uriel, Nir [1 ]
机构
[1] Columbia Univ, Irving Med Ctr, Dept Med, New York, NY 10027 USA
[2] NYU Langone Hlth, Dept Surg, New York, NY USA
[3] Northwestern Univ, Div Cardiol, Chicago, IL 60611 USA
[4] Univ Chicago, Med Ctr, Sect Cardiol, Dept Med, Chicago, IL 60637 USA
关键词
blood pressure; blood pressure measurement; monitoring; cardiovascular disease; hypertension; remote monitoring; TASK-FORCE;
D O I
10.1093/ajh/hpac020
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND Measuring an accurate blood pressure (BP) in ambulatory patients is critical for therapeutic decisions. An accurate noninvasive device that measures BP continuously could provide a more comprehensive assessment of BP. The aim of this study was to determine whether the LiveOne device, a cuffless wristband that provides continuous BP measurements, is accurate in comparison to an invasive arterial line (A-line). METHODS We enrolled hospitalized patients and healthy volunteers in this multicenter study. All patients had an invasive A-line. Waveforms were simultaneously downloaded from the A-line and LiveOne device. The primary outcome was the correlation between the LiveOne device and the A-line for systolic BP (SBP) and diastolic BP (DBP). RESULTS Thirty-four patients with 233 measurement periods were included. Mean age was 60.7 +/- 15.2 years, and 15 (44%) were female. The correlation for SBP was 0.91 and for DBP was 0.85. The mean band error was 0.0 +/- 6.9 mm Hg for SBP and 1.2 +/- 5.7 mm Hg for DBP. The mean absolute error was 8.2 +/- 5.8 mm Hg for SBP and 6.4 +/- 3.9 mm Hg for DBP. For SBP, 98% of LiveOne measurements were within 15 mm Hg and for DBP, 92% of LiveOne measurements were within 10 mm Hg. CONCLUSIONS The LiveOne device provides continuous, noninvasive BP measurements that are accurate in comparison to A-line measurements. The portability and unobtrusive nature of this device and the ability to provide continuous BP measurements may offer advantages over currently available BP monitors.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 50 条
  • [21] Embedded Device For Blood Pressure Monitoring
    Placencia, Franklin
    Manzano, Santiago
    Pallo, Juan P.
    Jurado, Marco
    2017 CHILEAN CONFERENCE ON ELECTRICAL, ELECTRONICS ENGINEERING, INFORMATION AND COMMUNICATION TECHNOLOGIES (CHILECON), 2017,
  • [22] Long Short Term Memory (LSTM)-based Cuffless Continuous Blood Pressure Monitoring
    Kumar, Vijay
    Goldy
    Paul, Kolin
    Chowdhary, Mahesh
    PROCEEDINGS OF THE 37TH INTERNATIONAL CONFERENCE ON VLSI DESIGN, VLSID 2024 AND 23RD INTERNATIONAL CONFERENCE ON EMBEDDED SYSTEMS, ES 2024, 2024, : 330 - 335
  • [23] Cuffless Continuous Blood Pressure Estimation From Pulse Morphology of Photoplethysmograms
    Yan, Wen-Rong
    Peng, Rong-Chao
    Zhang, Yuan-Ting
    Ho, Derek
    IEEE ACCESS, 2019, 7 : 141970 - 141977
  • [24] Cuffless Blood Pressure Monitoring from an Array of Wrist Bio-Impedance Sensors Using Subject-Specific Regression Models: Proof of Concept
    Ibrahim, Bassem
    Jafari, Roozbeh
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (06) : 1723 - 1735
  • [25] DiffCNBP: Lightweight Diffusion Model for IoMT-Based Continuous Cuffless Blood Pressure Waveform Monitoring Using PPG
    Ma, Chenbin
    Guo, Lishuang
    Zhang, Haonan
    Liu, Zhenchang
    Zhang, Guanglei
    IEEE INTERNET OF THINGS JOURNAL, 2025, 12 (01): : 61 - 80
  • [26] Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology
    Juan C. Ruiz-Rodríguez
    Adolf Ruiz-Sanmartín
    Vicent Ribas
    Jesús Caballero
    Alejandra García-Roche
    Jordi Riera
    Xavier Nuvials
    Miriam de Nadal
    Oriol de Sola-Morales
    Joaquim Serra
    Jordi Rello
    Intensive Care Medicine, 2013, 39 : 1618 - 1625
  • [27] Ability of a 24-h ambulatory cuffless blood pressure monitoring device to track blood pressure changes in clinical practice
    Derendinger, Felicia C.
    Vischer, Annina S.
    Krisai, Philipp
    Socrates, Thenral
    Schumacher, Christina
    Mayr, Michael
    Burkard, Thilo
    JOURNAL OF HYPERTENSION, 2024, 42 (04) : 662 - 671
  • [28] Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology
    Ruiz-Rodriguez, Juan C.
    Ruiz-Sanmartin, Adolf
    Ribas, Vicent
    Caballero, Jesus
    Garcia-Roche, Alejandra
    Riera, Jordi
    Nuvials, Xavier
    de Nadal, Miriam
    de Sola-Morales, Oriol
    Serra, Joaquim
    Rello, Jordi
    INTENSIVE CARE MEDICINE, 2013, 39 (09) : 1618 - 1625
  • [29] The Advent of Cuffless Mobile Device Blood Pressure Measurement: Remaining Challenges and Pitfalls
    Lee, Hae-Young
    Burkard, Thilo
    KOREAN CIRCULATION JOURNAL, 2022, 52 (03) : 198 - 204
  • [30] Development and evaluation of a home nocturnal blood pressure monitoring system using a wrist-cuff device
    Imai, Yutaka
    Asayama, Kei
    Fujiwara, Seisuke
    Saito, Kanako
    Sato, Hironori
    Haga, Toshikazu
    Satoh, Michihiro
    Murakami, Takahisa
    Metoki, Hirohito
    Kikuya, Masahiro
    Obara, Taku
    Inoue, Ryusuke
    Ohkubo, Takayoshi
    BLOOD PRESSURE MONITORING, 2018, 23 (06) : 318 - 326