Continuous Monitoring of Blood Pressure Using a Wrist-Worn Cuffless Device

被引:12
|
作者
Sayer, Gabriel [1 ]
Piper, Greta [2 ]
Vorovich, Esther [3 ]
Raikhelkar, Jayant [1 ]
Kim, Gene H. [4 ]
Rodgers, Daniel [4 ]
Shimbo, Daichi [1 ]
Uriel, Nir [1 ]
机构
[1] Columbia Univ, Irving Med Ctr, Dept Med, New York, NY 10027 USA
[2] NYU Langone Hlth, Dept Surg, New York, NY USA
[3] Northwestern Univ, Div Cardiol, Chicago, IL 60611 USA
[4] Univ Chicago, Med Ctr, Sect Cardiol, Dept Med, Chicago, IL 60637 USA
关键词
blood pressure; blood pressure measurement; monitoring; cardiovascular disease; hypertension; remote monitoring; TASK-FORCE;
D O I
10.1093/ajh/hpac020
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND Measuring an accurate blood pressure (BP) in ambulatory patients is critical for therapeutic decisions. An accurate noninvasive device that measures BP continuously could provide a more comprehensive assessment of BP. The aim of this study was to determine whether the LiveOne device, a cuffless wristband that provides continuous BP measurements, is accurate in comparison to an invasive arterial line (A-line). METHODS We enrolled hospitalized patients and healthy volunteers in this multicenter study. All patients had an invasive A-line. Waveforms were simultaneously downloaded from the A-line and LiveOne device. The primary outcome was the correlation between the LiveOne device and the A-line for systolic BP (SBP) and diastolic BP (DBP). RESULTS Thirty-four patients with 233 measurement periods were included. Mean age was 60.7 +/- 15.2 years, and 15 (44%) were female. The correlation for SBP was 0.91 and for DBP was 0.85. The mean band error was 0.0 +/- 6.9 mm Hg for SBP and 1.2 +/- 5.7 mm Hg for DBP. The mean absolute error was 8.2 +/- 5.8 mm Hg for SBP and 6.4 +/- 3.9 mm Hg for DBP. For SBP, 98% of LiveOne measurements were within 15 mm Hg and for DBP, 92% of LiveOne measurements were within 10 mm Hg. CONCLUSIONS The LiveOne device provides continuous, noninvasive BP measurements that are accurate in comparison to A-line measurements. The portability and unobtrusive nature of this device and the ability to provide continuous BP measurements may offer advantages over currently available BP monitors.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 50 条
  • [1] Validation and Acceptability of a Cuffless Wrist-Worn Wearable Blood Pressure Monitoring Device Among Users and Health Care Professionals: Mixed Methods Study
    Islam, Sheikh Mohammed Shariful
    Cartledge, Susie
    Karmakar, Chandan
    Rawstorn, Jonathan Charles
    Fraser, Steve F.
    Chow, Clara
    Maddison, Ralph
    JMIR MHEALTH AND UHEALTH, 2019, 7 (10):
  • [2] Cuffless and Continuous Blood Pressure Monitoring Using a Single Chest-Worn Device
    Park, Jonghyun
    Yang, Seungman
    Sohn, Jangjay
    Lee, Joonnyong
    Lee, Saram
    Ku, Yunseo
    Kim, Hee Chan
    IEEE ACCESS, 2019, 7 : 135231 - 135246
  • [3] The Promise and Illusion of Continuous, Cuffless Blood Pressure Monitoring
    Hu, Jiun-Ruey
    Park, Dae Yong
    Agarwal, Nikita
    Herzig, Matthew
    Ormseth, George
    Kaushik, Milan
    Giao, Duc M.
    Turkson-Ocran, Ruth-Alma N.
    Juraschek, Stephen P.
    CURRENT CARDIOLOGY REPORTS, 2023, 25 (10) : 1139 - 1149
  • [4] Cuffless Blood Pressure Monitoring Promises and Challenges
    Pandit, Jay A.
    Lores, Enrique
    Batlle, Daniel
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2020, 15 (10): : 1531 - 1538
  • [5] The Promise and Illusion of Continuous, Cuffless Blood Pressure Monitoring
    Jiun-Ruey Hu
    Dae Yong Park
    Nikita Agarwal
    Matthew Herzig
    George Ormseth
    Milan Kaushik
    Duc M. Giao
    Ruth-Alma N. Turkson-Ocran
    Stephen P. Juraschek
    Current Cardiology Reports, 2023, 25 : 1139 - 1149
  • [6] Validating cuffless continuous blood pressure monitoring devices
    Hu, Jiun-Ruey
    Martin, Gabrielle
    Iyengar, Sanjna
    Kovell, Lara C.
    Plante, Timothy B.
    van Helmond, Noud
    Dart, Richard A.
    Brady, Tammy M.
    Turkson-Ocran, Ruth-Alma N.
    Juraschek, Stephen P.
    CARDIOVASCULAR DIGITAL HEALTH JOURNAL, 2023, 4 (01): : 9 - 20
  • [7] WRIST-WORN FALL DETECTION DEVICE Development and Preliminary Evaluation
    Bertschi, Mattia
    Rossini, Leopoldo
    BIODEVICES 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2009, : 368 - 371
  • [8] Detection of Walk Tests in Free-Living Activities Using a Wrist-Worn Device
    Sokas, Daivaras
    Paliakaite, Birute
    Rapalis, Andrius
    Marozas, Vaidotas
    Bailon, Raquel
    Petrenas, Andrius
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [9] A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices
    Melville, Sarah
    Teskey, Robert
    Philip, Shona
    Simpson, Jeremy A.
    Lutchmedial, Sohrab
    Brunt, Keith R.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2018, 20 (04)
  • [10] Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study
    Kroll, Ryan R.
    Boyd, Gordon
    Maslove, David M.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2016, 18 (09)