Experimental validation of 3D printed patient-specific implants using digital image correlation and finite element analysis

被引:70
|
作者
Sutradhar, Alok [1 ,2 ]
Park, Jaejong [2 ]
Carrau, Diana [3 ]
Miller, Michael J. [1 ]
机构
[1] Ohio State Univ, Dept Plast Surg, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech & Aerosp Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Craniofacial implants; Topology optimization; Segmental bone defect; Digital image correlation; Masticatory simulation; RECONSTRUCTION; OPTIMIZATION; MODELS;
D O I
10.1016/j.compbiomed.2014.06.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
With the dawn of 3D printing technology, patient-specific implant designs are set to have a paradigm shift. A topology optimization method in designing patient-specific craniofacial implants has been developed to ensure adequate load transfer mechanism and restore the form and function of the mid-face. Patient-specific finite element models are used to design these implants and to validate whether they are viable for physiological loading such as mastication. Validation of these topology optimized finite element models using mechanical testing is a critical step. Instead of inserting the implants into a cadaver or patient, we embed the implants into the computer-aided skull model of a patient and, fuse them together to 3D print the complete skull model with the implant. Masticatory forces are applied in the molar region to simulate chewing and measure the stress-strain trajectory. Until recently, strain gages have been used to measure strains for validation. Digital Image Correlation (DIC) method is a relatively new technique for full-field strain measurement which provides a continuous deformation field data. The main objective of this study is to validate the finite element model of patient-specific craniofacial implants against the strain data from the DIC obtained during the mastication simulation and show that the optimized shapes provide adequate load-transfer mechanism. Patient-specific models are obtained from CT scans. The principal maximum and minimum strains are compared. The computational and experimental approach to designing patient-specific implants proved to be a viable technique for mid-face craniofacial reconstruction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8 / 17
页数:10
相关论文
共 50 条
  • [41] Experimental Investigation of Dynamic Fracture Patterns of 3D Printed Rock-like Material Under Impact with Digital Image Correlation
    Sharafisafa, Mansour
    Shen, Luming
    ROCK MECHANICS AND ROCK ENGINEERING, 2020, 53 (08) : 3589 - 3607
  • [42] Experimental study of shear properties of 3D woven composite using digital image correlation and acoustic emission
    E. M. Strungar
    A. S. Yankin
    E. M. Zubova
    A. V. Babushkin
    A. N. Dushko
    Acta Mechanica Sinica, 2020, 36 : 448 - 459
  • [43] Displacement monitoring of a pedestrian bridge using 3D digital image correlation
    Barros, Francisco
    Aguiar, Susana
    Sousa, Pedro J.
    Cachaco, Antonio
    Tavares, Paulo J.
    Moreira, Pedro M. G. P.
    Ranzal, D.
    Cardoso, N.
    Fernandes, N.
    Fernandes, R.
    Henriques, R.
    Cruz, P. M.
    Cannizzaro, A.
    4TH INTERNATIONAL CONFERENCE ON STRUCTURAL INTEGRITY (ICSI 2021), 2022, 37 : 880 - 887
  • [44] Micro-structural Deformation Field Analysis of Aluminum Foam using Finite Element Method and Digital Image Correlation
    Akhavan, B.
    Anaraki, A. Pourkamali
    Malian, A.
    Jamshidi, Y. Taraz
    INTERNATIONAL JOURNAL OF ENGINEERING, 2020, 33 (10): : 2065 - 2078
  • [45] Feasibility of an endovascular training and research environment with exchangeable patient specific 3D printed vascular anatomy Simulator with exchangeable patient-specific 3D-printed vascular anatomy for endovascular training and research
    Kaschwich, Mark
    Sieren, Malte
    Matysiak, Florian
    Bouchagiar, Juljan
    Dell, Annika
    Bayer, Andreas
    Ernst, Floris
    Ellebrecht, David
    Kleemann, Markus
    Horn, Marco
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2020, 231
  • [46] Patient-specific finite element analysis for assessing hip fracture risk in aging populations
    Chethan, K. N.
    Waldschmidt, Nadine Schmidt Genannt
    Corda, John Valerian
    Shenoy, Satish B.
    Shetty, Sawan
    Keni, Laxmikant G.
    Bhat, Shyamasunder N.
    Nikam, Nishant
    Mihcin, Senay
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (03)
  • [47] Investigation of Strain Measurements using Digital Image Correlation with a Finite Element Method
    Jian, Zhao
    Dong, Zhao
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2013, 17 (05) : 399 - 404
  • [48] Dissipative Behaviour Analysis of Reprocessed Polyethylene Terephthalate using Digital Image Correlation and Updated Finite Element Analysis
    Caro-Bretelle, A. S.
    Ienny, P.
    Nait-Ali, L. K.
    Bergeret, A.
    STRAIN, 2013, 49 (02) : 135 - 146
  • [49] Rapid Manufacturing, Regulatory Approval, and Utilization of Patient-specific 3D-Printed Titanium Implants for Complex Multistage Spinal Surgeries
    Yahanda, Alexander T.
    Barot, Karma
    Ruiz-Cardozo, Miguel A.
    Pet, Mitchell A.
    English, Ian
    Ohman, J. Westley
    Sanchez, Luis A.
    Hunt, Steven R.
    Brogan, David M.
    O'Keefe, Regis J.
    Albers, Brian
    Miller, Evan
    Goodwin, Matthew L.
    Molina, Camilo A.
    GLOBAL SPINE JOURNAL, 2025,
  • [50] Characterization of stress-strain behavior of composites using digital image correlation and finite element analysis
    He, Tiren
    Liu, Liu
    Makeev, Andrew
    Shonkwiler, Brian