Experimental validation of 3D printed patient-specific implants using digital image correlation and finite element analysis

被引:70
|
作者
Sutradhar, Alok [1 ,2 ]
Park, Jaejong [2 ]
Carrau, Diana [3 ]
Miller, Michael J. [1 ]
机构
[1] Ohio State Univ, Dept Plast Surg, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech & Aerosp Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Craniofacial implants; Topology optimization; Segmental bone defect; Digital image correlation; Masticatory simulation; RECONSTRUCTION; OPTIMIZATION; MODELS;
D O I
10.1016/j.compbiomed.2014.06.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
With the dawn of 3D printing technology, patient-specific implant designs are set to have a paradigm shift. A topology optimization method in designing patient-specific craniofacial implants has been developed to ensure adequate load transfer mechanism and restore the form and function of the mid-face. Patient-specific finite element models are used to design these implants and to validate whether they are viable for physiological loading such as mastication. Validation of these topology optimized finite element models using mechanical testing is a critical step. Instead of inserting the implants into a cadaver or patient, we embed the implants into the computer-aided skull model of a patient and, fuse them together to 3D print the complete skull model with the implant. Masticatory forces are applied in the molar region to simulate chewing and measure the stress-strain trajectory. Until recently, strain gages have been used to measure strains for validation. Digital Image Correlation (DIC) method is a relatively new technique for full-field strain measurement which provides a continuous deformation field data. The main objective of this study is to validate the finite element model of patient-specific craniofacial implants against the strain data from the DIC obtained during the mastication simulation and show that the optimized shapes provide adequate load-transfer mechanism. Patient-specific models are obtained from CT scans. The principal maximum and minimum strains are compared. The computational and experimental approach to designing patient-specific implants proved to be a viable technique for mid-face craniofacial reconstruction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8 / 17
页数:10
相关论文
共 50 条
  • [21] 3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models
    Dhou, S.
    Hurwitz, M.
    Mishra, P.
    Cai, W.
    Rottmann, J.
    Li, R.
    Williams, C.
    Wagar, M.
    Berbeco, R.
    Ionascu, D.
    Lewis, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09) : 3807 - 3824
  • [22] Rotating Vibration Measurement Using 3D Digital Image Correlation
    Y. Wang
    Z. Gao
    Z. Fang
    Y. Su
    Q. Zhang
    Experimental Mechanics, 2023, 63 : 565 - 579
  • [23] A 3D-printed patient-specific modular implants for pelvic reconstruction of bone tumors involving the sacroiliac joint
    Lv, Zhaorui
    Li, Zhenfeng
    Yang, Qiang
    Li, Jianmin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [24] Quantitative Assessment of Point-of-Care 3D-Printed Patient-Specific Polyetheretherketone (PEEK) Cranial Implants
    Sharma, Neha
    Aghlmandi, Soheila
    Dalcanale, Federico
    Seiler, Daniel
    Zeilhofer, Hans-Florian
    Honigmann, Philipp
    Thieringer, Florian M.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (16)
  • [25] Rotating Vibration Measurement Using 3D Digital Image Correlation
    Wang, Y.
    Gao, Z.
    Fang, Z.
    Su, Y.
    Zhang, Q.
    EXPERIMENTAL MECHANICS, 2023, 63 (03) : 565 - 579
  • [26] The design, production and clinical application of 3D patient-specific implants with drilling guides for acetabular surgery
    Merema, B. J.
    Kraeima, J.
    ten Duis, K.
    Wendt, K. W.
    Warta, R.
    Vos, E.
    Schepers, R. H.
    Witjes, M. J. H.
    IJpma, F. F. A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (11): : 2540 - 2547
  • [27] Establishment of design guidelines for patient-specific 3D-printed reconstruction implants for large distal femoral defects
    Wu, Po-Kuei
    Tsai, Wei-Che
    Wang, Hsuan-Wen
    Lin, Chun-Li
    MATERIALS & DESIGN, 2025, 251
  • [28] Confined Underwater Implosions Using 3D Digital Image Correlation
    Matos, Helio
    Gupta, Sachin
    LeBlanc, James M.
    Shukla, Arun
    DYNAMIC BEHAVIOR OF MATERIALS, VOL 1, 2017, : 147 - 151
  • [29] Comparison of specimen-specific vertebral body finite element models with experimental digital image correlation measurements
    Gustafson, Hannah M.
    Cripton, Peter A.
    Ferguson, Stephen J.
    Helgason, Benedikt
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 65 : 801 - 807
  • [30] The Creation of Finite Element Model by Using the Digital Image Correlation Method
    Trebuna, Frantisek