Electrochemical Impedance-Based Biosensors for the Label-Free Detection of the Nucleocapsid Protein from SARS-CoV-2

被引:31
|
作者
Cho, Hana [1 ,2 ]
Shim, Suhyun [1 ]
Cho, Won Woo [3 ]
Cho, Sungbo [4 ]
Baek, Hanseung [5 ]
Lee, Sang-Myung [3 ]
Shin, Dong-Sik [1 ,2 ]
机构
[1] Sookmyung Womens Univ, Dept Chem & Biol Engn, Seoul 04310, South Korea
[2] Sookmyung Womens Univ, Ind Collaborat Ctr, Seoul 04310, South Korea
[3] Cantis Inc, Ansan 15588, Gyeonggi Do, South Korea
[4] Gachon Univ, Dept Elect Engn, Seongnam Si 13120, Gyeonggi Do, South Korea
[5] Purme Nexon Children Rehabil Hosp, Comprehens Dent Care Ctr, Seoul 03918, South Korea
基金
新加坡国家研究基金会;
关键词
electrochemical sensor; nucleocapsid protein; SARS-CoV-2; impedance; label-free detection; FLOW IMMUNO ASSAY; FLUORESCENCE; PCR;
D O I
10.1021/acssensors.2c00317
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Diagnosis of coronavirus disease (COVID-19) is important because of the emergence and global spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time polymerase chain reaction (PCR) is widely used to diagnose COVID-19, but it is time-consuming and requires sending samples to test centers. Thus, the need to detect antigens for rapid on-site diagnosis rather than PCR is increasing. We quantified the nucleocapsid (N) protein in SARS-CoV-2 using an electro-immunosorbent assay (El-ISA) and a multichannel impedance analyzer with a 96-interdigitated microelectrode sensor (ToAD). The El-ISA measures impedance signals from residual detection antibodies after sandwich assays and thus offers highly specific, label-free detection of the N protein with low cross-reactivity. The ToAD sensor enables the real-time electrochemical detection of multiple samples in conventional 96-well plates. The limit of detection for the N protein was 0.1 ng/mL with a detection range up to 10 ng/mL. This system did not detect signals for the S protein. While this study focused on detecting the N protein in SARS-CoV-2, our system can also be widely applicable to detecting various biomolecules involved in antigen-antibody interactions.
引用
收藏
页码:1676 / 1684
页数:9
相关论文
共 50 条
  • [1] Label-free and reagent-less electrochemical detection of nucleocapsid protein of SARS-CoV-2: an ultrasensitive and disposable biosensor
    Aydin, Elif Burcu
    Aydin, Muhammet
    Sezginturk, Mustafa Kemal
    NEW JOURNAL OF CHEMISTRY, 2022, 46 (19) : 9172 - 9183
  • [2] Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector
    Rashed, Mohamed Z.
    Kopechek, Jonathan A.
    Priddy, Mariah C.
    Hamorsky, Krystal T.
    Palmer, Kenneth E.
    Mittal, Nikhil
    Valdez, Joseph
    Flynn, Joseph
    Williams, Stuart J.
    Biosensors and Bioelectronics, 2021, 171
  • [3] Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector
    Rashed, Mohamed Z.
    Kopechek, Jonathan A.
    Priddy, Mariah C.
    Hamorsky, Krystal T.
    Palmer, Kenneth E.
    Mittal, Nikhil
    Valdez, Joseph
    Flynn, Joseph
    Williams, Stuart J.
    BIOSENSORS & BIOELECTRONICS, 2021, 171
  • [4] Automatic label-free immunoassay with high sensitivity for rapid detection of SARS-CoV-2 nucleocapsid protein based on chemiluminescent magnetic beads
    Lyu, Aihua
    Jin, Tengchuan
    Wang, Shanshan
    Huang, Xiaoxue
    Zeng, Weihong
    Yang, Rui
    Cui, Hua
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 349
  • [5] Rapid Detection of SARS-CoV-2 Nucleocapsid Protein by a Label-Free Biosensor Based on Optical Fiber Cylindrical Micro-Resonator
    Xia, Ru-Lei
    Liu, Bin
    Hu, Yingying
    Liu, Juan
    Fu, Yue
    He, Xing-Dao
    Lu, Ping
    Farrell, Gerald
    Yuan, Jinhui
    Wu, Qiang
    IEEE SENSORS JOURNAL, 2023, 23 (12) : 12511 - 12518
  • [6] PCR- and label-free SARS-CoV-2 electrochemical immunosensor
    Vasquez, Viviana
    Orozco, Jahir
    MICROCHEMICAL JOURNAL, 2023, 193
  • [7] A self-enhanced electrochemiluminescence array chip for portable label-free detection of SARS-CoV-2 nucleocapsid protein with smartphone
    Nie, Wei
    Zhang, Ruoxian
    Hu, Chao
    Jin, Tengchuan
    Wei, Xi
    Cui, Hua
    BIOSENSORS & BIOELECTRONICS, 2023, 240
  • [8] Electrochemical Biosensors for SARS-CoV-2 Detection
    Andrianova M.S.
    Panova O.S.
    Titov A.A.
    Komarova N.V.
    Kuznetsov A.E.
    Moscow University Chemistry Bulletin, 2023, 78 (5) : 231 - 254
  • [9] Label-free electrochemical aptasensor for the detection of SARS-CoV-2 spike protein based on carbon cloth sputtered gold nanoparticles
    Adeel M.
    Asif K.
    Alshabouna F.
    Canzonieri V.
    Rahman M.M.
    Ansari S.A.
    Güder F.
    Rizzolio F.
    Daniele S.
    Biosensors and Bioelectronics: X, 2022, 12
  • [10] Recent Advances in Field-Effect Transistor-Based Biosensors for Label-Free Detection of SARS-CoV-2
    Yu, Haiyang
    Zhang, Huibin
    Liu, Zhe
    Feng, Linrun
    Su, Yuezeng
    Li, Jinhua
    Tang, Wei
    Yan, Feng
    SMALL SCIENCE, 2024, 4 (02):