Do we really need to repair the pronator quadratus after distal radius plating?

被引:6
作者
Pathak, Subodh [1 ]
Anjum, Rashid [1 ]
Gautam, Rakesh Kumar [1 ]
Maheshwari, Pritam [2 ]
Aggarwal, Jatin [1 ]
Sharma, Aryan [1 ]
Pruthi, Vineet [1 ]
机构
[1] MM Deemed Be Univ, Maharishi Markandeshwar Inst Med Sci & Res, Dept Orthopaed, Ambala, Haryana, India
[2] Pramukhswami Med Coll, Dept Orthoped, Anand, Gujarat, India
关键词
Distal radius fractures; Disabilities of arm; shoulder and hand; Volar plate; Pronator quadratus; Grip strength; POLLICIS LONGUS TENDON; FIXATION; COMPLICATIONS; FRACTURES; RUPTURE;
D O I
10.1016/j.cjtee.2019.10.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Fractures of distal radius are one of the common orthopaedic injuries. Placing the plate on volar surface requires release of underlying pronator quadratus (PQ) muscle. No consensus is present in the literature about the repair or not of the PQ. The purpose of this study was to evaluate the influence of PQ repair on functional outcome and complications. Methods: Retrospectively 83 patients of distal radius fractures managed with volar plating between 2014 and 2016 were evaluated. Demographic data, operative notes and physical therapy records were retrieved. Patients were divided into group A where PQ repair was done and group B where no repair was done. Functional data such as range of motion (ROM), grip strength, visual analogue scale (VAS) score and disabilities of arm, shoulder and hand (DASH) score at 4 weeks, 3 months, 6 months and finial follow-up were retrieved. Results: Totally 63 patients (n = 29 in group A and n = 34 in group B) with the mean age of 51.64 years were examined. Patients were followed up fora mean of 35.2 months (range 27.2-47.1 months) in group A and 38.6 months (range 28.6-51.0 months) in group B. Though functional outcome of the affected limb was not significantly different between two groups after 3 months, PQ repair did affect the recovery at an early stage. Repair group had significantly better ROM (p = 0.0383) and VAS score at 4 weeks (p = 0.017) while grip strength (p = 0.014) was significantly better at 3 months. Conclusions: Repair of PQ may provide pain relief and increased ROM in early postoperative period and hence every attempt should be made to achieve the repair. (C) 2019 Chinese Medical Association. Production and hosting by Elsevier B.V.
引用
收藏
页码:345 / 349
页数:5
相关论文
共 21 条
[1]  
Ahsan Zahab S, 2012, Hand (N Y), V7, P276, DOI 10.1007/s11552-012-9420-6
[2]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]   Complications of Volar Plate Fixation for Managing Distal Radius Fractures [J].
Berglund, Lisa M. ;
Messer, Terry M. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (06) :369-377
[4]  
Brown Emile N, 2011, Eplasty, V11, pe43
[5]   Flexor tendon injuries following locked volar plating of distal radius fractures [J].
Cross, Andrew W. ;
Schmidt, Christopher C. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02) :164-167
[6]   Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis. Surgical technique [J].
Dos Remedios, C. ;
Nebout, J. ;
Benlarbi, H. ;
Caremier, E. ;
Sam-Wing, J. -F. ;
Beya, R. .
CHIRURGIE DE LA MAIN, 2009, 28 (04) :224-229
[7]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[8]   Isokinetic evaluation of pronation after volar plating of a distal radius fracture [J].
Huh, Jung Kyu ;
Lim, Jae-Young ;
Song, Cheol Ho ;
Baek, Goo Hyun ;
Lee, Young Ho ;
Gong, Hyun Sik .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02) :200-204
[9]  
Johnson R K, 1976, J Hand Surg Am, V1, P205
[10]   Operative Management of Distal Radial Fractures with 2.4-Millimeter Locking Plates A Multicenter Prospective Case Series [J].
Jupiter, Jesse B. ;
Marent-Huber, M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :55-65