摘要
Combined positron emission tomography and computed tomography (PET/CT) has proven clinical utility, particularly in the diagnosis, staging, and management of cancer. The use of PET/CT has grown substantially in the past few years, with an increasing number of hospitals and imaging centers installing PET/CT systems each year. The combination of 2 procedures, which each imparting a radiation dose and hence the potential for deleterious health effects, creates unique radiation safety issues. This article addresses the radiation safety issues posed by PET/CT with regard to the protection and safety of PET/CT personnel, the public, and adult and pediatric patients. © 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 37 条
[1]  
[Anonymous], 2008, Cancer Facts Figures 2008
[2]   Pediatric body MDCT: A 5-year follow-up survey of scanning parameters used by pediatric radiologists [J].
Arch, Michael E. ;
Frush, Donald P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) :611-617
[3]  
Beyer T, 2000, J NUCL MED, V41, P1369
[4]  
Bixler A, 1999, J Nucl Med Technol, V27, P14
[5]   Positron emission tomography/computed tomography: Protocol issues and options [J].
Blodgett, TM ;
McCook, BM ;
Federle, MP .
SEMINARS IN NUCLEAR MEDICINE, 2006, 36 (02) :157-168
[6]   PET/CT: Form and function [J].
Blodgett, Todd M. ;
Meltzer, Carolyn C. ;
Townsend, David W. .
RADIOLOGY, 2007, 242 (02) :360-385
[7]  
BUSHBEIG JT, 2002, ESSENTIAL PHYS MED I
[8]   Image analysis in patients with cancer studied with a combined PET and CT scanner [J].
Charron, M ;
Beyer, T ;
Bohnen, NN ;
Kinahan, PE ;
Dachille, M ;
Jerin, J ;
Nutt, R ;
Meltzer, CC ;
Villemagne, V ;
Townsend, DW .
CLINICAL NUCLEAR MEDICINE, 2000, 25 (11) :905-910
[9]   Are restrictions to behaviour of patients required following fluorine-18 fluorodeoxyglucose positron emission tomographic studies? [J].
Cronin, B ;
Marsden, PK ;
O'Doherty, MJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (02) :121-128
[10]  
*CTR MED MED SERV, CAG00181R CTR MED ME, P1