Proximal Fiber Tip Damage during Holmium: YAG and Thulium Fiber Laser Ablation of Kidney Stones

被引:2
|
作者
Wilson, Christopher R. [1 ]
Hardy, Luke A. [1 ]
Irby, Pierce B. [2 ]
Fried, Nathaniel M. [1 ,2 ]
机构
[1] Univ N Carolina, Dept Phys & Opt Sci, Charlotte, NC 28223 USA
[2] Carolinas Med Ctr, McKay Dept Urol, Charlotte, NC 28203 USA
来源
PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII | 2016年 / 9689卷
关键词
ablation; damage; fiber; holmium; kidney stones; lithotripsy; proximal; thulium; OPTICAL-FIBERS; LITHOTRIPSY;
D O I
10.1117/12.2207895
中图分类号
TH742 [显微镜];
学科分类号
摘要
The Thulium fiber laser (TFL) is being studied as an alternative to Holmium: YAG laser for lithotripsy. TFL beam originates within an 18-mu m-core thulium doped silica fiber, and its near single mode, Gaussian beam profile enables transmission of higher laser power through smaller fibers than possible during Holmium laser lithotripsy. This study examines whether TFL beam profile also reduces proximal fiber tip damage compared to Holmium laser multimodal beam. TFL beam at wavelength of 1908 nm was coupled into 105-mu m-core silica fibers, with 35-mJ energy, 500-mu s pulse duration, and pulse rates of 50-500 Hz. For each pulse rate, 500,000 pulses were delivered. Magnified images of proximal fiber surfaces were taken before and after each trial. For comparison, 20 single-use, 270-mu m-core fibers were collected after clinical Holmium laser lithotripsy procedures using standard settings (600 mJ, 350 mu s, 6 Hz). Total laser energy, number of laser pulses, and laser irradiation time were recorded, and fibers were rated for damage. For TFL studies, output power was stable, and no proximal fiber damage was observed after delivery of 500,000 pulses at settings up to 35 mJ, 500 Hz, and 17.5 W average power. In contrast, confocal microscopy images of fiber tips after Holmium lithotripsy showed proximal fiber tip degradation in all 20 fibers. The proximal fiber tip of a 105-mu m-core fiber transmitted 17.5 W of TFL power without degradation, compared to degradation of 270-mu m-core fibers after transmission of 3.6 W of Holmium laser power. The smaller and more uniform TFL beam profile may improve fiber lifetime, and potentially reduce costs for the surgical disposables as well.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Laser absorption coefficient of thulium fiber laser and holmium Yag laser: in what scale
    Nguyen, Dong
    WORLD JOURNAL OF UROLOGY, 2023, 41 (04) : 1207 - 1208
  • [22] Laser Efficiency and Laser Safety: Holmium YAG vs. Thulium Fiber Laser
    Sierra, Alba
    Corrales, Mariela
    Somani, Bhaskar
    Traxer, Olivier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (01)
  • [23] Laser absorption coefficient of thulium fiber laser and holmium Yag laser: in what scale
    Dong Nguyen
    World Journal of Urology, 2023, 41 : 1207 - 1208
  • [24] Thulium:YAG laser: a good compromise between holmium:YAG and thulium fiber laser for endoscopic lithotripsy? A narrative review
    Chicaud, Marie
    Corrales, Mariela
    Kutchukian, Stessy
    Solano, Catalina
    Candela, Luigi
    Doizi, Steeve
    Traxer, Olivier
    Panthier, Frederic
    WORLD JOURNAL OF UROLOGY, 2023, 41 (12) : 3437 - 3447
  • [25] Thulium:YAG laser: a good compromise between holmium:YAG and thulium fiber laser for endoscopic lithotripsy? A narrative review
    Marie Chicaud
    Mariela Corrales
    Stessy Kutchukian
    Catalina Solano
    Luigi Candela
    Steeve Doizi
    Olivier Traxer
    Frédéric Panthier
    World Journal of Urology, 2023, 41 : 3437 - 3447
  • [26] COMPARATIVE EVALUATION OF TEMPERATURE GENERATION DURING LASER LITHOTRIPSY: THULIUM FIBER LASER, PULSED THULIUM:YAG, AND HOLMIUM:YAG WITH PULSE MODULATION IN AN EX VIVO PORCINE KIDNEY MODEL
    Gao, Bruce M.
    Sheetz, Tyler
    Griffiths, Luke
    Ali, Aymon
    Sims, Harel C.
    Huang, Tiffany R.
    Hadidi, Yezan
    Saadat, Seyedamirvala
    Finegan, Jamie L.
    Nguyen, Vi
    Nackeeran, Sirpi
    Bechis, Seth K.
    Patel, Roshan
    JOURNAL OF UROLOGY, 2025, 213 (5S):
  • [27] Thulium fiber laser ablation of kidney stones using a 50-μm-core silica optical fiber
    Blackmon, Richard L.
    Hutchens, Thomas C.
    Hardy, Luke A.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    OPTICAL ENGINEERING, 2015, 54 (01)
  • [28] Ablation rates with Holmium:YAG and Thulium Fiber Laser: Influence of the stone phantom homogeneity. An in vitro study
    Kutchukian, S.
    Doizi, S.
    Lapouge, P.
    Germain, T.
    Dragos, L.
    Berthe, L.
    Solano, C.
    Candela, L.
    Corrales, M.
    Chicaud, M.
    Traxer, O.
    Panthier, F.
    PROGRES EN UROLOGIE, 2023, 33 (8-9): : 456 - 462
  • [29] Comparison of Holmium: YAG and Thulium Fiber Lasers for Lithotripsy
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [30] Effects of holmium: YAG laser energy settings on fiber tip degradation
    Goldsmith, Z. G.
    Rai, S.
    Neisius, A.
    Astroza, G. M.
    Wang, A. J.
    Iqbal, M. W.
    Simmons, W. N.
    Preminger, G. M.
    Lipkin, M. E.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 69 - 69