摘要
The purpose of this research was to develop an algorithm for a wearable device that would prevent people from drowning in swimming pools. The device should detect pre-drowning symptoms and alert the rescue staff. The proposed detection method is based on analyzing real-time data collected from a set of sensors, including a pulse oximeter. The pulse oximetry technique is used for measuring the heart rate and oxygen saturation in the subject's blood. It is an optical method; subsequently, the measurements obtained this way are highly sensitive to interference from the subject's motion. To eliminate noise caused by the subject's movement, accelerometer data were used in the system. If the acceleration sensor does not detect movement, a biosensor is activated, and an analysis of selected physiological parameters is performed. Such a setup of the algorithm allows the device to distinguish situations in which the person rests and does not move from situations in which the examined person has lost consciousness and has begun to drown.
引用
收藏
页数:18
相关论文
共 31 条
[1]   Automated and Intelligent System for Monitoring Swimming Pool Safety Based on the IoT and Transfer Learning [J].
Alotaibi, Aziz .
ELECTRONICS, 2020, 9 (12) :1-13
[2]  
Alshbatat A.I.N., 2020, 2020 ADV SCI ENG TEC, P1, DOI [DOI 10.1109/ASET48392.2020.9118248, 10.1109/ASET48392.2020.9118248]
[3]   An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform [J].
Alvarado-Serrano, Carlos ;
Samuel Luna-Lozano, Pablo ;
Pallas-Areny, Ramon .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 27 :96-102
[4]  
[Anonymous], 2018, RECOMMENDED CONFIGUR
[5]  
[Anonymous], 2011, ANAL COVARIANCE ALTE
[6]  
[Anonymous], 2018, HIGH SENSITIVITY PUL
[7]   A non-contact method based on multiple signal classification algorithm to reduce the measurement time for accurately heart rate detection [J].
Bechet, P. ;
Mitran, R. ;
Munteanu, M. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (08)
[8]   Investigating sources of inaccuracy in wearable optical heart rate sensors [J].
Bent, Brinnae ;
Goldstein, Benjamin A. ;
Kibbe, Warren A. ;
Dunn, Jessilyn P. .
NPJ DIGITAL MEDICINE, 2020, 3 (01)
[9]   The use of drones and a machine-learning model for recognition of simulated drowning victims-A feasibility study [J].
Claesson, A. ;
Schierbeck, S. ;
Hollenberg, J. ;
Forsberg, S. ;
Nordberg, P. ;
Ringh, M. ;
Olausson, M. ;
Jansson, A. ;
Nord, A. .
RESUSCITATION, 2020, 156 :196-201
[10]  
Hafen BB., 2021, StatPearls