A beam model for focused proton pencil beams

被引:25
作者
Almhagen, E. [1 ,2 ]
Boersma, D. J. [1 ,3 ]
Nystrom, H. [2 ,4 ]
Ahnesjo, A. [1 ]
机构
[1] Uppsala Univ, Dept Immunol Genet & Pathol, Med Radiat Sci, Uppsala, Sweden
[2] Skandion Clin, Uppsala, Sweden
[3] ACMIT Gmbh, A-2700 Wiener Neustadt, Austria
[4] DCPT, Aarhus, Denmark
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 52卷
关键词
Proton therapy; Monte Carlo; Beam model; MONTE-CARLO SIMULATIONS; THERAPY;
D O I
10.1016/j.ejmp.2018.06.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: We present a beam model for Monte Carlo simulations of the IBA pencil beam scanning dedicated nozzle installed at the Skandion Clinic. Within the nozzle, apart from entrance and exit windows and the two ion chambers, the beam traverses vacuum, allowing for a beam that is convergent downstream of the nozzle exit. Materials and methods: We model the angular, spatial and energy distributions of the beam phase space at the nozzle exit with single Gaussians, controlled by seven energy dependent parameters. The parameters were determined from measured profiles and depth dose distributions. Verification of the beam model was done by comparing measured and GATE acquired relative dose distributions, using plan specific log files from the machine to specify beam spot positions and energy. Results: GATE-based simulations with the acquired beam model could accurately reproduce the measured data. The gamma index analysis comparing simulated and measured dose distributions resulted in > 95% global gamma index pass rates (3%/2 mm) for all depths. Conclusion: The developed beam model was found to be sufficiently accurate for use with GATE e.g. for applications in quality assurance (QA) or patient motion studies with the IBA pencil beam scanning dedicated nozzles.
引用
收藏
页码:27 / 32
页数:6
相关论文
共 14 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] Gottschalk B, ARXIV12044470V2PHYSI
  • [3] GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13) : 4223 - 4244
  • [4] A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) : 5203 - 5219
  • [5] ICRU, 2014, J ICRU, V14, P31, DOI DOI 10.1093/JICRU/NDW038
  • [6] Evaluation of the gamma dose distribution comparison method
    Low, DA
    Dempsey, JF
    [J]. MEDICAL PHYSICS, 2003, 30 (09) : 2455 - 2464
  • [7] The role of protons in modern and biologically-guided radiotherapy
    Nystrom, Hakan
    [J]. ACTA ONCOLOGICA, 2010, 49 (07) : 1124 - 1131
  • [8] Monte Carlo simulations with time-dependent geometries to investigate effects of organ motion with high temporal resolution
    Paganetti, H
    Jiang, HY
    Adams, JA
    Chen, GT
    Rietzel, E
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 942 - 950
  • [9] Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility
    Paganetti, H
    Jiang, H
    Lee, SY
    Kooy, HM
    [J]. MEDICAL PHYSICS, 2004, 31 (07) : 2107 - 2118