Assessing Stapes Piston Position Using Computed Tomography: A Cadaveric Study

被引:19
作者
Hahn, Yoav [1 ]
Diaz, Rodney [1 ]
Hartman, Jonathan [2 ]
Bobinski, Matthew [2 ]
Brodie, Hilary [1 ]
机构
[1] Univ Calif Davis, Med Ctr, Dept Otolaryngol Head & Neck Surg, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Med Ctr, Dept Neuroradiol, Sacramento, CA 95817 USA
关键词
Computed tomographic scan; Piston; Stapedectomy; Stapedectomy complications; Stapedectomy vertigo; PERSISTENT VERTIGO; SURGERY; CT;
D O I
10.1097/MAO.0b013e31818de5cd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis: Temporal bone computed tomographic (CT) scanning in the postoperative stapedotomy patient is inaccurate in assessing stapes piston position within the vestibule. Background: Poststapedotomy patients that have persistent vertigo may undergo CT scanning to assess the position of the stapes piston within the vestibule to rule out overly deep insertion. Vertigo is a recognized complication of the deep piston, and CT evaluation is often recommended. The accuracy of CT scan in this setting is unestablished. Methods: Stapedotomy was performed on 12 cadaver ears, and stainless steel McGee pistons were placed. The cadaver heads were then scanned using a fine-cut temporal bone protocol. Temporal bone dissection was performed with microscopic measurement of the piston depth in the vestibule. These values were compared with depth of intravestibular penetration measured on CT scan by 4 independent measurements. Results: The intravestibular penetration as assessed by computed tomography was consistently greater than the value found on cadaveric anatomic dissection. The radiographic bias was greater when piston location within the vestibule was shallower. The axial CT scan measurement was 0.53 mm greater, on average, than the anatomic measurement. On average, the coronal CT measurement was 0.68 mm greater than the anatomic measurement. The degree of overestimation of penetration, however, was highly inconsistent. Conclusion: Standard temporal bone CT scan is neither an accurate nor precise examination of stapes piston depth within the vestibule. We found that CT measurement consistently overstated intravestibular piston depth. Computed tomography is not a useful study in the evaluation of piston depth for poststapedectomy vertigo and is of limited value in this setting.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 15 条
  • [1] Delayed vertigo after stapes surgery
    Albera, R
    Canale, A
    Lacilla, M
    Cavalot, AL
    Ferrero, V
    [J]. LARYNGOSCOPE, 2004, 114 (05) : 860 - 862
  • [2] Relationship of the utriculus and sacculus to the stapes footplate: Anatomic implications for sound- and or pressure-induced otolith activation
    Backous, DD
    Minor, LB
    Aboujaoude, ES
    Nager, GT
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (06) : 548 - 553
  • [3] Fisch U, 1965, Acta Otolaryngol, V60, P515, DOI 10.3109/00016486509127035
  • [4] CT and MR imaging after middle ear surgery
    Kösling, S
    Bootz, F
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2001, 40 (02) : 113 - 118
  • [5] Kosling S, 1995, INVEST RADIOL, V30, P712
  • [6] MAYOR GP, 2007, AN OTORRINOLARINGOL, V34, P447
  • [7] Imaging of postoperative failures and complications in stapes surgery for otosclerosis
    Naggara, O
    Williams, MT
    Ayache, D
    Heran, F
    Piekarski, JD
    [J]. JOURNAL DE RADIOLOGIE, 2005, 86 (12): : 1749 - 1761
  • [8] OBERASCHER G, 1987, HNO, V35, P255
  • [9] IDENTIFICATION OF MIDDLE-EAR IMPLANTS IN HIGH-RESOLUTION COMPUTED-TOMOGRAPHY
    OBERASCHER, G
    GROBOVSCHEK, M
    [J]. LARYNGOLOGIE RHINOLOGIE OTOLOGIE VEREINIGT MIT MONATSSCHRIFT FUR OHRENHEILKUNDE, 1988, 67 (01): : 17 - 22
  • [10] UTRICLE, SACCULE, AND COCHLEAR DUCT IN RELATION TO STAPEDOTOMY - A HISTOLOGIC HUMAN TEMPORAL BONE STUDY
    PAUW, BKH
    POLLAK, AM
    FISCH, U
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1991, 100 (12) : 966 - 970