Effect of vapor condensation on forced convection heat transfer of moistened gas

被引:57
作者
Liang, Yongbin [1 ]
Che, Defu [1 ]
Kang, Yanbin [1 ]
机构
[1] Xian Jiaotong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
关键词
D O I
10.1007/s00231-006-0148-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
The forced convection heat transfer with water vapor condensation is studied both theoretically and experimentally when wet flue gas passes downwards through a bank of horizontal tubes. Extraordinarily, discussions are concentrated on the effect of water vapor condensation on forced convection heat transfer. In the experiments, the air-steam mixture is used to simulate the flue gas of a natural gas fired boiler, and the vapor mass fraction ranges from 3.2 to 12.8%. By theoretical analysis, a new dimensionless number defined as augmentation factor is derived to account for the effect of condensation of relatively small amount of water vapor on convection heat transfer, and a consequent correlation is proposed based on the experimental data to describe the combined convection-condensation heat transfer. Good agreement can be found between the values of the Nusselt number obtained from the experiments and calculated by the correlation. The maximum deviation is within +/- 6%. The experimental results also shows that the convection-condensation heat transfer coefficient increases with Reynolds number and bulk vapor mass fraction, and is 1 similar to 3.5 times that of the forced convection without condensation.
引用
收藏
页码:677 / 686
页数:10
相关论文
共 22 条
[1]   CONDENSATION OF STEAM AND R113 ON A BANK OF HORIZONTAL TUBES IN THE PRESENCE OF A NONCONDENSING GAS [J].
ABDULLAH, R ;
COOPER, JR ;
BRIGGS, A ;
ROSE, JW .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1995, 10 (03) :298-306
[2]  
Cao Y, 2000, J ENG THERMOPHYS, V21, P729
[3]   Heat and mass transfer characteristics of simulated high moisture flue gases [J].
Che, DF ;
Da, YD ;
Zhuang, ZN .
HEAT AND MASS TRANSFER, 2005, 41 (03) :250-256
[4]   Evaluation of retrofitting a conventional natural gas fired boiler into a condensing boiler [J].
Che, DF ;
Liu, YH ;
Gao, CY .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (20) :3251-3266
[5]   Mass transfer (absorption) coefficients - Prediction from data on great transfer and fluid friction [J].
Chilton, TH ;
Colburn, AP .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1934, 26 :1183-1187
[6]  
Colburn AP, 1933, T AM INST CHEM ENG, V29, P174
[7]   Design of cooler condensers for mixtures of vapors with noncondensing gases [J].
Colburn, AP ;
Hougen, OA .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1934, 26 :1178-1182
[8]  
Grimison E.D., 1937, T ASME, V59, P583
[9]   An algebraically-explicit correlation for forced-convection condensation of steam-air and steam-hydrogen on horizontal plates [J].
Groff, MK ;
Ormiston, SJ ;
Soliman, HM ;
Srzic, V ;
Ramirez-Iraheta, OA .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2002, 29 (08) :1047-1056
[10]  
HAMPSON H, 1951, P GENERAL DISCUSSION, P58