Treatment monitoring and thermometry for therapeutic focused ultrasound

被引:82
作者
Rivens, I.
Shaw, A.
Civale, J.
Morris, H.
机构
[1] Royal Marsden NHS Fdn Trust, Joint Dept Phys, Inst Canc Res, Sutton SM2 5PT, Surrey, England
[2] Natl Phys Lab, Qual Life Div, Teddington TW11 0LW, Middx, England
基金
英国工程与自然科学研究理事会;
关键词
therapeutic high intensity focused ultrasound (HIFU; FUS); oncology; non-invasive magnetic resonance (MR) or ultrasound (US) treatment imaging; thin-film thermocouples; thermometry; NONINVASIVE TEMPERATURE ESTIMATION; GUIDED TUMOR ABLATION; PROTON CHEMICAL-SHIFT; IN-VIVO; TISSUE-DAMAGE; UTERINE FIBROIDS; LESION FORMATION; THERMAL LESIONS; EXPERIMENTAL VALIDATION; SYSTEM-DEVELOPMENT;
D O I
10.1080/02656730701207842
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Therapeutic ultrasound is currently enjoying increasingly widespread clinical use especially for the treatment of cancer of the prostate, liver, kidney, breast, pancreas and bone, as well as for the treatment of uterine fibroids. The optimum method of treatment delivery varies between anatomical sites, but in all cases monitoring of the treatment is crucial if extensive clinical acceptance is to be achieved. Monitoring not only provides the operating clinician with information relating to the effectiveness of treatment, but can also provide an early alert to the onset of adverse effects in normal tissue. This paper reviews invasive and non-invasive monitoring methods that have been applied to assess the extent of treatment during the delivery of therapeutic ultrasound in the laboratory and clinic (follow-up after treatment is not reviewed in detail). The monitoring of temperature and, importantly, the way in which this measurement can be used to estimate the delivered thermal dose, is dealt with as a separate special case. Already therapeutic ultrasound has reached a stage of development where it is possible to attempt real-time feedback during exposure in order to optimize each and every delivery of ultrasound energy. To date, data from MR imaging have shown better agreement with the size of regions of damage than those from diagnostic ultrasound, but novel ultrasonic techniques may redress this balance. Whilst MR currently offers the best method for non-invasive temperature measurement, the ultrasound techniques under development, which could potentially offer more rapid visualisation of results, are discussed.
引用
收藏
页码:121 / 139
页数:19
相关论文
共 160 条
[1]   MR thermometry-based feedback control of efficacy and safety in minimum-time thermal therapies:: Phantom and in-vivo evaluations [J].
Arora, D ;
Cooley, D ;
Perry, T ;
Guo, JY ;
Richardson, A ;
Moellmer, J ;
Hadley, R ;
Parker, D ;
Skliar, M ;
Roemer, RB .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2006, 22 (01) :29-42
[2]   Direct thermal dose control of constrained focused ultrasound treatments: phantom and in vivo evaluation [J].
Arora, D ;
Cooley, D ;
Perry, T ;
Skliar, M ;
Roemer, RB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08) :1919-1935
[3]   EXPERIMENTAL VALIDATION OF PREDICTED TEMPERATURE RISES IN TISSUE-MIMICKING MATERIALS [J].
BACON, DR ;
SHAW, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (11) :1647-1659
[4]   Use of overpressure to assess the role of bubbles in focused ultrasound lesion shape in vitro [J].
Bailey, MR ;
Couret, LN ;
Sapozhnikov, OA ;
Khokhlova, VA ;
Ter Haar, G ;
Vaezy, S ;
Shi, XG ;
Martin, R ;
Crum, LA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (05) :695-708
[5]  
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P149, DOI 10.1016/0301-5629(79)90083-8
[6]   Ultrasound elasticity imaging: definition and technology [J].
Bamber, JC .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S327-S330
[7]   Doppler ultrasound detection of shear waves remotely induced in tissue phantoms and tissue in vitro [J].
Barannik, EA ;
Girnyk, A ;
Tovstiak, V ;
Marusenko, AI ;
Emelianov, SY ;
Sarvazyan, AP .
ULTRASONICS, 2002, 40 (1-8) :849-852
[8]   Quantitative MR temperature monitoring of high-intensity focused ultrasound therapy [J].
Bohris, C ;
Schreiber, WG ;
Jenne, J ;
Simiantonakis, I ;
Rastert, R ;
Zabel, HJ ;
Huber, P ;
Bader, R ;
Brix, G .
MAGNETIC RESONANCE IMAGING, 1999, 17 (04) :603-610
[9]   MR monitoring of focused ultrasound surgery in a breast tissue model in vivo [J].
Bohris, C ;
Jenne, JW ;
Rastert, R ;
Simiantonakis, I ;
Brix, G ;
Spoo, J ;
Hlavac, M ;
Nemeth, R ;
Huber, PE ;
Debus, J .
MAGNETIC RESONANCE IMAGING, 2001, 19 (02) :167-175
[10]  
BRUGGMOSER G, 1986, LOCOREGIONAL HIGH FR