Somatosensory evoked potential: Preventing brachial plexus injury in transaxillary robotic surgery

被引:12
|
作者
Huang, Shuo [1 ]
Garstka, Meghan E. [1 ]
Murcy, Mohammed A. [1 ]
Bamford, Jeremey A. [2 ]
Kang, Sang-Wook [1 ]
Randolph, Gregory W. [3 ]
Kandil, Emad [1 ]
机构
[1] Tulane Univ, Sch Med, Dept Surg, 1430 Tulane Ave,Room 8510,Box SL-22, New Orleans, LA 70112 USA
[2] Tulane Univ, Sch Med, Dept Neurosurg, 1430 Tulane Ave, New Orleans, LA 70112 USA
[3] Massachusetts Eye & Ear Infirm, Dept Otolaryngol, 243 Charles St, Boston, MA 02114 USA
关键词
Brachial plexus injury; robotic transaxillary thyroidectomy; somatosensory evoked potentials; intraoperative nerve monitoring; ENDOSCOPIC THYROIDECTOMY; AXILLARY APPROACH; NERVE INJURY; EXPERIENCE; MANAGEMENT; GASLESS;
D O I
10.1002/lary.27611
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis The potential for brachial plexopathy due to arm positioning is a major concern regarding the robotic transaxillary approach. Intraoperative nerve monitoring via somatosensory evoked potential (SSEP) has been suggested to prevent such injury. In this study, we examined the use of SSEP in detecting imminent brachial plexus traction during robotic transaxillary thyroid and parathyroid surgery. Study Design Retrospective case series. Methods A analysis was performed for all patients undergoing robotic transaxillary surgery with continuous intraoperative SSEP monitoring at a North American institution between 2015 and 2017. A significant intraoperative SSEP change was defined as a decrease in signal amplitude of >50% or an increase in latency of >10% from baseline established during preoperative positioning. Results One hundred thirty-seven robotic transaxillary surgeries using SSEP monitoring were performed on 123 patients. Seven patients (5.1%) developed significant changes, with an average SSEP amplitude reduction of 73% +/- 12% recorded at the signals' nadir. Immediate arm repositioning resulted in recovery of signals and complete return to baseline parameters in 14.3 +/- 9.2 minutes. There was no difference in age (40.4 +/- 9.4 years vs. 44.5 +/- 13.4 years; P = .31) or body mass index (27.3 +/- 3.7 kg/m(2) vs. 26.9 +/- 6.1 kg/m(2); P = .79) between cases with and without SSEP change. Operative time was shorter for patients with significant SSEP change (131.6 +/- 14.7 minutes vs. 146.5 +/- 46.7 minutes; P = .048). There were no postoperative positional brachial plexus injuries. Conclusions SSEP is a novel, safe, and reliable tool in detection of position-related brachial plexus neuropathy. Intraoperative monitoring using SSEP can play a vital role in early recognition and prevention of injury during robotic transaxillary thyroid and parathyroid surgery. Level of Evidence 4 Laryngoscope, 129:2663-2668, 2019
引用
收藏
页码:2663 / 2668
页数:6
相关论文
共 50 条
  • [31] Trendelenburg Position-Induced Brachial Plexus Injury Following Laparoscopic Rectal Cancer Surgery
    Aydin Yavuz
    Filiz Banu Ethemoglu
    Mehmet Olpak
    Gurel Nessar
    Indian Journal of Surgery, 2021, 83 : 782 - 783
  • [32] Pain following human brachial plexus injury with spinal cord root avulsion and the effect of surgery
    Berman, JS
    Birch, R
    Anand, P
    PAIN, 1998, 75 (2-3) : 199 - 207
  • [33] Somatosensory-Evoked Potential Asymmetry in Medullary Ischemia During Cervical Spine Surgery
    Cam Thuy Tran
    Khoo, Larry T.
    Martin, Neil A.
    Fong, Sylvia S.
    Nuwer, Marc R.
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2012, 29 (01) : 17 - 22
  • [34] INTRAOPERATIVE SOMATOSENSORY-EVOKED POTENTIAL MONITORING DURING ACUTE PELVIC FRACTURE SURGERY
    HELFET, DL
    KOVAL, KJ
    HISSA, EA
    PATTERSON, S
    DIPASQUALE, T
    SANDERS, R
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (01) : 28 - 34
  • [35] Therapeutic Effect of Warm Needling Therapy Combined with Rehabilitation Therapy for Brachial Plexus Injury after Surgery
    Cui Jia-wen
    Chu Li-xi
    ZhouJun-ming
    Zhang Shen-yu
    JournalofAcupunctureandTuinaScience, 2013, 11 (01) : 46 - 52
  • [36] Therapeutic effect of warm needling therapy combined with rehabilitation therapy for brachial plexus injury after surgery
    Cui J.-W.
    Chu L.-X.
    Zhou J.-M.
    Zhang S.-Y.
    Journal of Acupuncture and Tuina Science, 2013, 11 (1) : 46 - 52
  • [37] Median nerve somatosensory evoked potential alarm related to head and neck positioning for carotid surgery
    Alba Díaz-Baamonde
    Roberto Peláez-Cruz
    Maria J. Téllez
    John Lantis
    Sedat Ulkatan
    Journal of Clinical Monitoring and Computing, 2023, 37 : 699 - 704
  • [38] Somatosensory- and motor-evoked potential monitoring during spine and spinal cord surgery
    Costa, P.
    Bruno, A.
    Bonzanino, M.
    Massaro, F.
    Caruso, L.
    Vincenzo, I.
    Ciaramitaro, P.
    Montalenti, E.
    SPINAL CORD, 2007, 45 (01) : 86 - 91
  • [39] Somatosensory evoked potential monitoring during positioning of the patient for posterior fossa surgery in the semisitting position
    Deinsberger, W
    Christophis, P
    Jödicke, A
    Heesen, M
    Böker, DK
    NEUROSURGERY, 1998, 43 (01) : 36 - 40
  • [40] Somatosensory- and motor-evoked potential monitoring during spine and spinal cord surgery
    P Costa
    A Bruno
    M Bonzanino
    F Massaro
    L Caruso
    I Vincenzo
    P Ciaramitaro
    E Montalenti
    Spinal Cord, 2007, 45 : 86 - 91