Pleth Variability Index Predicts Fluid Responsiveness in Mechanically Ventilated Adults During General Anesthesia for Noncardiac Surgery

被引:28
|
作者
Siswojo, Andy Sisnata [1 ]
Wong, Daniel Mun-Yen [2 ]
Tuong Dien Phan [2 ]
Kluger, Roman [2 ]
机构
[1] Box Hill Hosp, Dept Anaesthesia, Box Hill, Vic 3128, Australia
[2] St Vincents Hosp, Fitzroy, Vic 3065, Australia
关键词
Pleth variability index; stroke volume; fluid responsiveness; hemodynamic monitoring; pulse oximeter; esophageal Doppler monitoring; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; CENTRAL VENOUS-PRESSURE; OF-THE-LITERATURE; CARDIAC-OUTPUT; HOSPITAL STAY; ESOPHAGEAL DOPPLER; PULSE OXIMETER; TRANSESOPHAGEAL DOPPLER; VOLUME;
D O I
10.1053/j.jvca.2014.04.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To investigate whether the pleth variability index (PVI), derived noninvasively from a pulse oximeter probe, would predict fluid responsiveness in patients undergoing noncardiac surgeries. Design: A clinical, prospective, observational study. Setting: Operating room of a tertiary care hospital. Participants: Twenty-nine adult patients undergoing a range of noncardiac surgeries, requiring general anesthesia, tracheal intubation, and mechanical ventilation. Interventions: Intravenous volume expansion with 500 mL of colloid following induction of general anesthesia and after a period of hemodynamic stability before the start of surgery. Measurements and Main Results: Baseline values for PVI and stroke volume index, derived from an esophageal Doppler monitor, were compared with final values after the volume expansion. Patients were classified into fluid responders and nonresponders based on a stroke volume index increase of >= 10%. The optimal cut-off value for baseline pleth variability index for predicting fluid responsiveness was determined. There were 17 responders (59%) to the 500-mL volume expansion. Baseline PVI value was significantly different between responders and nonresponders (16.5 +/- 6.4% v 10.3 +/- 2.7%; p = 0.004). Receiver operating characteristic analysis demonstrated significant predictive ability of an increase in stroke volume index for PVI with area under the curve of 0.84 (95% confidence interval = 0.69-0.99). The optimal cut-off value for baseline PVI was 10.5%, with a sensitivity of 88% and a specificity of 67%. Conclusions: Pleth variability index is predictive of fluid responsiveness in adult patients undergoing noncardiac surgery. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1505 / 1509
页数:5
相关论文
共 50 条
  • [41] Pleth variability index during preoxygenation could predict anesthesia-induced hypotension: A prospective, observational study
    Kim, Yoon Jung
    Seo, Jeong-Hwa
    Lee, Hyung-Chul
    Kim, Hee-Soo
    JOURNAL OF CLINICAL ANESTHESIA, 2023, 90
  • [42] Pleth variability index during preoxygenation did not reliably predict anesthesia-induced hypotension
    Crystal, George J.
    Pagel, Paul S.
    Salem, M. Ramez
    JOURNAL OF CLINICAL ANESTHESIA, 2024, 93
  • [43] Respiratory Variability of Pulmonary Velocity-Time Integral As a New Gauge of Fluid Responsiveness For Mechanically Ventilated Patients in the ICU
    Gavaud, Ariane
    Nguyen, Lee S.
    Caubel, Antoine
    Grillet, Guillaume
    Donal, Erwan
    Belliard, Guillaume
    CRITICAL CARE MEDICINE, 2019, 47 (04) : E310 - E316
  • [44] Passive leg raising test induced changes in plethysmographic variability index to assess fluid responsiveness in critically ill mechanically ventilated patients with acute circulatory failure
    Mallat, Jihad
    Lemyze, Malcolm
    Fischer, Marc-Olivier
    JOURNAL OF CRITICAL CARE, 2024, 79
  • [45] The effects of pneumoperitoneum and patient position on the perfusion index and pleth variability index during laparoscopic bariatric surgery
    Arslantas, Reyhan
    Arslantas, Mustafa Kemal
    Tore Altun, Gulbin
    Corman Dincer, Pelin
    MARMARA MEDICAL JOURNAL, 2020, 33 (02): : 54 - 60
  • [46] A pilot study of the pleth variability index as an indicator of volume-responsive hypotension in newborn infants during surgery
    Bagci, Soyhan
    Mueller, Nicole
    Mueller, Andreas
    Heydweiller, Andreas
    Bartmann, Peter
    Franz, Axel R.
    JOURNAL OF ANESTHESIA, 2013, 27 (02) : 192 - 198
  • [47] The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children-A prospective observational study
    Weber, Frank
    Rashmi, Bharat K.
    Karaoz-Bulut, Gulhan
    Dogger, Jaap
    de Heer, Iris J.
    Prasser, Christopher
    PEDIATRIC ANESTHESIA, 2020, 30 (10) : 1124 - 1131
  • [48] Effects of intraoperative fluid management on hemodynamics and tissue oxygenation according to the Pleth Variability Index in thoracic surgery
    Savaser, Semanur
    Akdogan, Ali
    Erturk, Engin
    Kutanis, Dilek
    Gul, Rauf
    Karapolat, Bekir Sami
    Kilic, Kubra Nur
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 32 (03): : 307 - 316
  • [49] Carotid doppler indices do not predict fluid responsiveness in mechanically ventilated patients undergoing coronary artery bypass grafting surgery
    Khan, Saba
    Mishra, Sandeep Kumar
    Parida, Satyen
    Jha, Ajay Kumar
    Padala, Sri Rama Ananta Nagabhushanam
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 4418 - 4424
  • [50] Plethysmographic variability index to predict fluid responsiveness in the general surgical paediatric population
    Desgranges, Francois-Pierrick
    Zorio, Violette
    Jacquet-Lagreze, Matthias
    Lilot, Marc