Pleth Variability Index Predicts Fluid Responsiveness in Mechanically Ventilated Adults During General Anesthesia for Noncardiac Surgery

被引:28
|
作者
Siswojo, Andy Sisnata [1 ]
Wong, Daniel Mun-Yen [2 ]
Tuong Dien Phan [2 ]
Kluger, Roman [2 ]
机构
[1] Box Hill Hosp, Dept Anaesthesia, Box Hill, Vic 3128, Australia
[2] St Vincents Hosp, Fitzroy, Vic 3065, Australia
关键词
Pleth variability index; stroke volume; fluid responsiveness; hemodynamic monitoring; pulse oximeter; esophageal Doppler monitoring; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; CENTRAL VENOUS-PRESSURE; OF-THE-LITERATURE; CARDIAC-OUTPUT; HOSPITAL STAY; ESOPHAGEAL DOPPLER; PULSE OXIMETER; TRANSESOPHAGEAL DOPPLER; VOLUME;
D O I
10.1053/j.jvca.2014.04.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To investigate whether the pleth variability index (PVI), derived noninvasively from a pulse oximeter probe, would predict fluid responsiveness in patients undergoing noncardiac surgeries. Design: A clinical, prospective, observational study. Setting: Operating room of a tertiary care hospital. Participants: Twenty-nine adult patients undergoing a range of noncardiac surgeries, requiring general anesthesia, tracheal intubation, and mechanical ventilation. Interventions: Intravenous volume expansion with 500 mL of colloid following induction of general anesthesia and after a period of hemodynamic stability before the start of surgery. Measurements and Main Results: Baseline values for PVI and stroke volume index, derived from an esophageal Doppler monitor, were compared with final values after the volume expansion. Patients were classified into fluid responders and nonresponders based on a stroke volume index increase of >= 10%. The optimal cut-off value for baseline pleth variability index for predicting fluid responsiveness was determined. There were 17 responders (59%) to the 500-mL volume expansion. Baseline PVI value was significantly different between responders and nonresponders (16.5 +/- 6.4% v 10.3 +/- 2.7%; p = 0.004). Receiver operating characteristic analysis demonstrated significant predictive ability of an increase in stroke volume index for PVI with area under the curve of 0.84 (95% confidence interval = 0.69-0.99). The optimal cut-off value for baseline PVI was 10.5%, with a sensitivity of 88% and a specificity of 67%. Conclusions: Pleth variability index is predictive of fluid responsiveness in adult patients undergoing noncardiac surgery. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1505 / 1509
页数:5
相关论文
共 50 条
  • [31] Non-invasive measurement of digital plethysmographic variability index to predict fluid responsiveness in mechanically ventilated children: A systematic review and meta-analysis of diagnostic test accuracy studies
    Desgranges, Francois-Pierrick
    Bouvet, Lionel
    Neto, Edmundo Pereira de Souza
    Evain, Jean-Noel
    Terrisse, Hugo
    Joosten, Alexandre
    Desebbe, Olivier
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2023, 42 (03)
  • [32] Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre
    Cannesson, M.
    Desebbe, O.
    Rosamel, P.
    Delannoy, B.
    Robin, J.
    Bastien, O.
    Lehot, J. -J.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) : 200 - 206
  • [33] Pleth variability index or stroke volume optimization during open abdominal surgery: a randomized controlled trial
    Bahlmann, Hans
    Hahn, Robert G.
    Nilsson, Lena
    BMC ANESTHESIOLOGY, 2018, 18
  • [34] Evaluation of Hemodynamic Changes and Fluid Response during Anesthesia in Lumbar Disc Hernias with Pleth Variability Index (PVI)
    Sarihan, Seda
    Koyuncu, Tolga
    Kazancioglu, Leyla
    Batcik, Sule
    Kazdal, Hizir
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (03):
  • [35] Detection of fluid responsiveness by changes of perfusion index and pleth-variability index during passive leg raising in spontaneously breathing post-surgical patients: a prospective interventional study
    Rauch, Simon
    Seraglio, Paolo Mario
    Cappello, Tomas Dal
    Roveri, Giulia
    Falk, Markus
    Bock, Matthias
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2025,
  • [36] Prediction of volume responsiveness using pleth variability index in patients undergoing cardiac surgery after cardiopulmonary bypass
    Sebastian Haas
    Constantin Trepte
    Martin Hinteregger
    Rebecca Fahje
    Bjoern Sill
    Lena Herich
    Daniel A. Reuter
    Journal of Anesthesia, 2012, 26 : 696 - 701
  • [37] Does pneumoperitoneum affect perfusion index and pleth variability index in patients receiving combined epidural and general anesthesia?
    Wajima, Zen'ichiro
    Shiga, Toshiya
    Imanaga, Kazuyuki
    BIOSCIENCE TRENDS, 2017, 11 (06) : 667 - 674
  • [38] Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography
    de Souza Neto, E. Pereira
    Grousson, S.
    Duflo, F.
    Ducreux, C.
    Joly, H.
    Convert, J.
    Mottolese, C.
    Dailler, F.
    Cannesson, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (06) : 856 - 864
  • [39] Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis
    Sandroni, Claudio
    Cavallaro, Fabio
    Marano, Cristina
    Falcone, Chiara
    De Santis, Paolo
    Antonelli, Massimo
    INTENSIVE CARE MEDICINE, 2012, 38 (09) : 1429 - 1437
  • [40] Evaluation of fluid responsiveness with dynamic superior vena cava collapsibility index in mechanically ventilated patients
    Li, Yaru
    Jiang, Luyang
    Wang, Lu
    Dou, Dou
    Feng, Yi
    PERIOPERATIVE MEDICINE, 2023, 12 (01)