Pleth Variability Index Predicts Fluid Responsiveness in Mechanically Ventilated Adults During General Anesthesia for Noncardiac Surgery

被引:28
|
作者
Siswojo, Andy Sisnata [1 ]
Wong, Daniel Mun-Yen [2 ]
Tuong Dien Phan [2 ]
Kluger, Roman [2 ]
机构
[1] Box Hill Hosp, Dept Anaesthesia, Box Hill, Vic 3128, Australia
[2] St Vincents Hosp, Fitzroy, Vic 3065, Australia
关键词
Pleth variability index; stroke volume; fluid responsiveness; hemodynamic monitoring; pulse oximeter; esophageal Doppler monitoring; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; CENTRAL VENOUS-PRESSURE; OF-THE-LITERATURE; CARDIAC-OUTPUT; HOSPITAL STAY; ESOPHAGEAL DOPPLER; PULSE OXIMETER; TRANSESOPHAGEAL DOPPLER; VOLUME;
D O I
10.1053/j.jvca.2014.04.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To investigate whether the pleth variability index (PVI), derived noninvasively from a pulse oximeter probe, would predict fluid responsiveness in patients undergoing noncardiac surgeries. Design: A clinical, prospective, observational study. Setting: Operating room of a tertiary care hospital. Participants: Twenty-nine adult patients undergoing a range of noncardiac surgeries, requiring general anesthesia, tracheal intubation, and mechanical ventilation. Interventions: Intravenous volume expansion with 500 mL of colloid following induction of general anesthesia and after a period of hemodynamic stability before the start of surgery. Measurements and Main Results: Baseline values for PVI and stroke volume index, derived from an esophageal Doppler monitor, were compared with final values after the volume expansion. Patients were classified into fluid responders and nonresponders based on a stroke volume index increase of >= 10%. The optimal cut-off value for baseline pleth variability index for predicting fluid responsiveness was determined. There were 17 responders (59%) to the 500-mL volume expansion. Baseline PVI value was significantly different between responders and nonresponders (16.5 +/- 6.4% v 10.3 +/- 2.7%; p = 0.004). Receiver operating characteristic analysis demonstrated significant predictive ability of an increase in stroke volume index for PVI with area under the curve of 0.84 (95% confidence interval = 0.69-0.99). The optimal cut-off value for baseline PVI was 10.5%, with a sensitivity of 88% and a specificity of 67%. Conclusions: Pleth variability index is predictive of fluid responsiveness in adult patients undergoing noncardiac surgery. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1505 / 1509
页数:5
相关论文
共 50 条
  • [21] The Ability of Pleth Variability Index to Predict the Hemodynamic Effects of Positive End-Expiratory Pressure in Mechanically Ventilated Patients Under General Anesthesia
    Desebbe, Olivier
    Boucau, Cecile
    Farhat, Fadi
    Bastien, Olivier
    Lehot, Jean-Jacques
    Cannesson, Maxime
    ANESTHESIA AND ANALGESIA, 2010, 110 (03) : 792 - 798
  • [22] The Pleth Variability Index as a Guide to Fluid Therapy in Dogs Undergoing General Anesthesia: A Preliminary Study
    Vicenti, Caterina
    Romagnoli, Noemi
    Stabile, Marzia
    Lambertini, Carlotta
    Piemontese, Claudia
    Spaccini, Francesca
    Foglia, Armando
    Lacitignola, Luca
    Crovace, Antonio
    Staffieri, Francesco
    VETERINARY SCIENCES, 2024, 11 (09)
  • [23] Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index
    Broch, O.
    Bein, B.
    Gruenewald, M.
    Hoecker, J.
    Schoettler, J.
    Meybohm, P.
    Steinfath, M.
    Renner, J.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (06) : 686 - 693
  • [24] Non-invasive prediction of fluid responsiveness in infants using pleth variability index
    Renner, J.
    Broch, O.
    Gruenewald, M.
    Scheewe, J.
    Francksen, H.
    Jung, O.
    Steinfath, M.
    Bein, B.
    ANAESTHESIA, 2011, 66 (07) : 582 - 589
  • [25] Pleth variability index and respiratory system compliance to direct PEEP settings in mechanically ventilated patients, an exploratory study
    Zhou, Jing
    Han, Yi
    SPRINGERPLUS, 2016, 5
  • [26] Agreement between Pleth Variability Index and oesophageal Doppler to predict fluid responsiveness
    Bahlmann, H.
    Hahn, R. G.
    Nilsson, L.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2016, 60 (02) : 183 - 192
  • [27] Prediction of volume responsiveness using pleth variability index in patients undergoing cardiac surgery after cardiopulmonary bypass
    Haas, Sebastian
    Trepte, Constantin
    Hinteregger, Martin
    Fahje, Rebecca
    Sill, Bjoern
    Herich, Lena
    Reuter, Daniel A.
    JOURNAL OF ANESTHESIA, 2012, 26 (05) : 696 - 701
  • [28] Pleth Variability Index-Based Goal-Directed Fluid Management in Patients Undergoing Elective Gynecologic Surgery
    Yilmaz, Gulseren
    Akca, Aysu
    Kiyak, Huseyin
    Can, Esra
    Aydin, Alev
    Salihoglu, Ziya
    MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2022, 56 (02): : 220 - 226
  • [29] Reliability of pleth variability index in predicting preload responsiveness of mechanically ventilated patients under various conditions: a systematic review and meta-analysis
    Tianyu Liu
    Chao Xu
    Min Wang
    Zheng Niu
    Dunyi Qi
    BMC Anesthesiology, 19
  • [30] Stroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese
    Fu, Qiang
    Mi, Weidong
    Zhang, Hong
    BIOSCIENCE TRENDS, 2012, 6 (01) : 38 - 43