Differences in Vessel Healing Between Sirolimus- and Everolimus-Eluting Stent Implantation for Bifurcation Lesions: The J-REVERSE Optical Coherence Tomography Substudy

被引:5
作者
Terashita, Daisuke [1 ]
Otake, Hiromasa [1 ]
Shinke, Toshiro [1 ]
Murasato, Yoshinobu [2 ,3 ,4 ]
Kinoshita, Yoshihisa [5 ]
Yamawaki, Masahiro [6 ]
Takeda, Yoshihiro [7 ]
Fujii, Kenichi [8 ]
Yamada, Shin-ichiro [9 ]
Shimada, Yoshihisa [10 ]
Yamashita, Takehiro [11 ]
Yumoto, Kazuhiko [12 ]
Hirata, Ken-ichi [1 ]
机构
[1] Kobe Univ, Dept Cardiovasc Med, Kobe, Hyogo 657, Japan
[2] Kyushu Med Ctr, Clin Res Inst, Fukuoka, Japan
[3] Kyushu Med Ctr, Ctr Cardiovasc, Dept Cardiol, Fukuoka, Japan
[4] New Yukuhashi Hosp, Dept Cardiovasc Med, Yukuhashi, Japan
[5] Toyohashi Heart Ctr, Dept Cardiovasc Med, Toyohashi, Aichi, Japan
[6] Saiseikai Yokohama Eastern Hosp, Dept Cardiovasc Med, Yokohama, Kanagawa, Japan
[7] Rinku Gen Med Ctr, Dept Cardiovasc Med, Izumisano, Japan
[8] Hyogo Med Univ, Dept Cardiovasc Med, Nishinomiya, Hyogo 663, Japan
[9] Himeji Cardiovasc Ctr, Dept Cardiovasc Med, Himeji, Hyogo, Japan
[10] Shiroyama Hosp, Dept Cardiovasc Med, Habikino, Japan
[11] Cardiovasc Ctr Hokkaido Ono Hosp, Dept Cardiovasc Med, Sapporo, Hokkaido, Japan
[12] Yokohama Rosai Hosp, Dept Cardiovasc Med, Yokohama, Kanagawa, Japan
关键词
RESTENOSIS; THROMBOSIS; IMPACT;
D O I
10.1016/j.cjca.2015.06.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We aimed to clarify the differences in vessel healing after stenting of bifurcation lesions using sirolimus-eluting stents (SESs) or everolimus-eluting stents (EESs). Methods: Japanese Registry Study in Comparison Between Everolimus-Eluting Stent and Sirolimus-Eluting Stent for the Bifurcation Lesion (J-REVERSE) is a prospective multicentre registry of 303 bifurcation lesions that were treated with provisional SES or EES with or without final kissing inflation. The first 115 lesions at selected study sites were predefined for inclusion in the optical coherence tomography (OCT) substudy, and 9-month follow-up OCT was conducted in 64 lesions (SES, n = 18; EES, n = 46). In addition to standard OCT parameters, stent eccentricity index (SEI; minimum divided by the maximum stent diameter), neointimal unevenness score (NUS; maximum neointimal thickness in the cross-section [CS] divided by the average neointimal thickness [NIT] of the same CS; uniformity of the neointima suppression) were averaged for each segment (proximal, bifurcation, and distal segments). Results: Overall, the average stent and luminal area, NIT, and frequency of uncovered struts were similar. The frequency of malapposed struts and SEI were significantly lower in the EES group than in the SES group. The EES group had a significantly smaller NUS in the proximal and distal segments. Conclusions: EESs offer homogeneous vessel healing with less malapposition in the treatment of bifurcation lesions.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 50 条
  • [31] Incomplete arterial healing 8 years after the implantation of sirolimus-eluting stent. In vivo visualization by optical coherence tomography
    Bouki, Konstantina P.
    Sakkali, Eleni K.
    Apostolou, Thomas S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (04) : 625 - 627
  • [32] Optical Coherence Tomography Evaluation of Late Strut Coverage Patterns Between First-Generation Drug-Eluting Stents and Everolimus-Eluting Stent
    Toledano Delgado, Francisco Javier
    Pan Alvarez-Ossorio, Manuel
    de Lezo Cruz-Conde, Jose Suarez
    Mazuelos Bellido, Francisco
    Romero Moreno, Miguel Angel
    Medina Fernandez-Aceytuno, Alfonso
    de Lezo Herreros de Tejada, Javier Suarez
    Ojeda Pineda, Soledad
    Segura Saint-Gerons, Jose Maria
    Pavlovic, Djordje
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (05) : 720 - 726
  • [33] Cut-off value of strut-vessel distance for the resolution of acute incomplete stent apposition in the early phase using serial optical coherence tomography after cobalt-chromium everolimus-eluting stent implantation
    Oda, Hideto
    Itoh, Tomonori
    Sasaki, Wataru
    Uchimura, Yohei
    Taguchi, Yuya
    Kaneko, Kyosuke
    Sakamoto, Tsubasa
    Goto, Iwao
    Sakuma, Masafumi
    Ishida, Masaru
    Kikuchi, Tatsuo
    Terashita, Daisuke
    Otake, Hiromasa
    Morino, Yoshihiro
    Shinke, Toshiro
    JOURNAL OF CARDIOLOGY, 2020, 75 (06) : 641 - 647
  • [34] Relationship between peri-strut low intensity areas and vascular healing response after everolimus-eluting bioresorbable scaffold implantation: An optical coherence tomography study
    Sato, Takao
    Jose, John
    El-Mawardy, Mohamed
    Sulimov, Dmitriy S.
    Toelg, Ralph
    Richardt, Gert
    Abdel-Wahab, Mohamed
    JOURNAL OF CARDIOLOGY, 2017, 69 (3-4) : 606 - 612
  • [35] Three-month evaluation of strut healing using a novel optical coherence tomography analytical method following bioresorbable polymer everolimus-eluting stent implantation in humans: the TIMELESS study
    Vesga, Boris
    Hernandez, Hector
    Moncada, Miguel
    Gasior, Pawel
    Higuera, Sergio
    Dager, Antonio
    Arana, Camilo
    Delgado, Juan A.
    Genereux, Philippe
    Maehara, Akiko
    Granada, Juan F.
    CORONARY ARTERY DISEASE, 2017, 28 (02) : 126 - 134
  • [36] Vascular healing in high-bleeding-risk patients at 3-month after everolimus-eluting stent versus biolimus A9-coated stent implantation: insights from analysis of optical coherence tomography and coronary angioscopy
    Koiwaya, Hiroshi
    Nishihira, Kensaku
    Kadooka, Kosuke
    Kuriyama, Nehiro
    Shibata, Yoshisato
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2023, 38 (01) : 64 - 74
  • [37] Randomized clinical trial of abluminus DES plus sirolimus-eluting stent versus everolimus-eluting DES for percutaneous coronary intervention in patients with diabetes mellitus: An optical coherence tomography study
    Maurina, Matteo
    Chiarito, Mauro
    Leone, Pier Pasquale
    Testa, Luca
    Montorfano, Matteo
    Reimers, Bernhard
    Esposito, Giovanni
    Monti, Francesco
    Ferrario, Maurizio
    Latib, Azeem
    Colombo, Antonio
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (06) : 1020 - 1033
  • [38] Optical Coherence Tomography Analysis of the Stenting of Saphenous Vein Graft (SOS) Xience V Study: Use of the Everolimus-Eluting Stent in Saphenous Vein Graft Lesions
    Papayannis, Aristotelis C.
    Michael, Tesfaldet T.
    Yangirova, Dinara
    Abdel-karim, Abdul-rahman
    Kohlhaas, Julia
    Mahmood, Arif
    Addo, Tayo
    Haagen, Donald
    Makke, Lorenza
    Roesle, Michele
    Rangan, Bavana
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (08) : 390 - 394
  • [39] Temporal changes of incomplete stent apposition during early phase after everolimus-eluting stent implantation: serial optical coherence tomography analyses at 2-week and 4-month
    Wakabayashi, Hirokazu
    Ando, Hirohiko
    Nakano, Yusuke
    Takashima, Hiroaki
    Waseda, Katsuhisa
    Shimoda, Masahiro
    Ohashi, Hirofumi
    Suzuki, Akihiro
    Sakurai, Shinichiro
    Amano, Tetsuya
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (02) : 411 - 417
  • [40] Optical coherence tomography follow-up 18 months after titanium-nitride-oxidecoated versus everolimus-eluting stent implantation in patients with acute coronary syndrome
    Karjalainen, Pasi
    Paana, Tuomas
    Ylitalo, Antti
    Sia, Jussi
    Nammas, Wail
    ACTA RADIOLOGICA, 2017, 58 (09) : 1077 - 1084