Development of a 1K x 1K, 8-12 μm QWIP array

被引:18
作者
Jhabvala, M. [1 ]
Choi, K. K.
Monroy, C.
La, A.
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[2] USA, Res Lab, Adelphi, MD 20783 USA
关键词
15;
D O I
10.1016/j.infrared.2006.10.029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the on-going evolution of GaAs quantum well infrared photodetectors (QWIPs) we have developed a 1024 X 1024 (1K x 1K), 8-12 mu m infrared focal plane array (FPA). This 1 megapixel detector array is a hybrid using an L3/Cincinnati Electronics silicon readout integrated circuit (ROIC) bump bonded to a GaAs QWIP array fabricated jointly by engineers at the Goddard Space Flight Center (GSFC) and the Army Research Laboratory (ARL). We have integrated the 1K x 1K array into an SE-IR based imaging camera system and performed tests over the 50-80 K temperature range achieving BLIP performance at an operating temperature of 57 K. The GaAs array is relatively easy to fabricate once the superlattice structure of the quantum wells has been defined and grown. The overall arrays costs are currently dominated by the costs associated with the silicon readout since the GaAs array fabrication is based on high yield, well-established GaAs processing capabilities. One of the advantages of GaAs QWIP technology is the ability to fabricate arrays in a fashion similar to and compatible with silicon IC technology. The designer's ability to easily select the spectral response of the material from 3 mu m to beyond 15 mu m is the result of the success of band-gap engineering and the Army Research Lab is a leader in this area. In this paper we will present the first results of our 1K x 1K QWIP array development including fabrication methodology, test data and imaging capabilities. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:234 / 239
页数:6
相关论文
共 14 条
  • [1] DETECTION WAVELENGTH OF QUANTUM-WELL INFRARED PHOTODETECTORS
    CHOI, KK
    [J]. JOURNAL OF APPLIED PHYSICS, 1993, 73 (10) : 5230 - 5236
  • [2] Corrugated quantum well infrared photodetectors for material characterization
    Choi, KK
    Chen, CJ
    Tsui, DC
    [J]. JOURNAL OF APPLIED PHYSICS, 2000, 88 (03) : 1612 - 1623
  • [3] CHOI KK, 1998, SPIE, V3379, P441
  • [4] Medical infrared imaging - differentiating facts from fiction, and the impact of high precision quantum well infrared photodetector camera systems, and other factors, in its reemergence
    Fauci, MA
    Breiter, R
    Cabanski, W
    Fick, W
    Koch, R
    Ziegler, J
    Gunapala, SD
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2001, 42 (3-5) : 337 - 344
  • [5] FREUND F, 2002, AGU 2002 SPRING M SE
  • [6] GAUGHAN R, 2003, BIOPHOTONICS INT, P20
  • [7] GOLDBERG A, 1999, P 1999 IRIS SPEC GRO
  • [8] GOLDBERG A, 2003, P SPIE
  • [9] Development of a 4-15 μm infrared GaAs hyperspectral QWIP imager
    Jhabvala, M
    Gunapala, S
    Reuter, D
    Choi, KK
    Bandara, S
    Liu, J
    La, A
    Banks, S
    Cho, J
    Hwang, T
    Tsay, S
    Rafol, D
    Huet, H
    Chauvet, N
    Huss, T
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2003, 44 (5-6) : 445 - 455
  • [10] JHABVALA M, 2003, SPIE