Rapid PCR in a continuous flow device

被引:175
作者
Hashimoto, M [1 ]
Chen, PC
Mitchell, MW
Nikitopoulos, DE
Soper, SA
Murphy, MC
机构
[1] Louisiana State Univ, Dept Mech Engn, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
来源
LAB ON A CHIP | 2004年 / 4卷 / 06期
关键词
D O I
10.1039/b406860b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Continuous flow polymerase chain reaction (CFPCR) devices are compact reactors suitable for microfabrication and the rapid amplification of target DNAs. For a given reactor design, the amplification time can be reduced simply by increasing the flow velocity through the isothermal zones of the device; for flow velocities near the design value, the PCR cocktail reaches thermal equilibrium at each zone quickly, so that near ideal temperature profiles can be obtained. However, at high flow velocities there are penalties of an increased pressure drop and a reduced residence time in each temperature zone for the DNA/reagent mixture, that potentially affect amplification efficiency. This study was carried out to evaluate the thermal and biochemical effects of high flow velocities in a spiral, 20 cycle CFPCR device. Finite element analysis (FEA) was used to determine the steady-state temperature distribution along the micro-channel and the temperature of the DNA/reagent mixture in each temperature zone as a function of linear velocity. The critical transition was between the denaturation (95 degreesC) and renaturation (55 degreesC-68 degreesC) zones; above 6 mm s(-1) the fluid in a passively-cooled channel could not be reduced to the desired temperature and the duration of the temperature transition between zones increased with increased velocity. The amplification performance of the CFPCR as a function of linear velocity was assessed using 500 and 997 base pair (bp) fragments from lambda-DNA. Amplifications at velocities ranging from 1 mm s(-1) to 20 mm s(-1) were investigated. The 500 bp fragment could be observed in a total reaction time of 1.7 min (5.2 s cycle(-1)) and the 997 bp fragment could be detected in 3.2 min (9.7 s cycle 21). The longer amplification time required for detection of the 997 bp fragment was due to the device being operated at its enzyme kinetic limit (i.e., Taq polymerase deoxynucleotide incorporation rate).
引用
收藏
页码:638 / 645
页数:8
相关论文
共 50 条
  • [1] BEJAT Y, UNPUB J MICROLITH MI
  • [2] BEJAT YD, 2001, THESIS LOUISIANA STA
  • [3] Microfabricated structures for integrated DNA analysis
    Burns, MA
    Mastrangelo, CH
    Sammarco, TS
    Man, FP
    Webster, JR
    Johnson, BN
    Foerster, B
    Jones, D
    Fields, Y
    Kaiser, AR
    Burke, DT
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (11) : 5556 - 5561
  • [4] A closed cycle capillary polymerase chain reaction machine
    Chiou, J
    Matsudaira, P
    Sonin, A
    Ehrlich, D
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (09) : 2018 - 2021
  • [5] A miniaturized cyclic PCR device - modeling and experiments
    Chou, CF
    Changrani, R
    Roberts, P
    Sadler, D
    Burdon, J
    Zenhausern, F
    Lin, S
    Mulholland, A
    Swami, N
    Terbrueggen, R
    [J]. MICROELECTRONIC ENGINEERING, 2002, 61-2 : 921 - 925
  • [6] Continuous segmented-flow polymerase chain reaction for high-throughput miniaturized DNA amplification
    Curcio, M
    Roeraade, J
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (01) : 1 - 7
  • [7] Fabrication of graphite masks for deep and ultra-deep X-ray lithography
    Desta, YM
    Aigeldinger, G
    Zanca, KJ
    Coane, P
    Göttert, J
    Murphy, MC
    [J]. MATERIALS AND DEVICE CHARACTERIZATION IN MICROMACHINING III, 2000, 4175 : 122 - 130
  • [8] DRYDEN HL, 1932, HYDRODYNAMICS B, V84, P197
  • [9] Fluorescent high-density labeling of DNA:: error-free substitution for a normal nucleotide
    Földes-Papp, Z
    Angerer, B
    Ankenbauer, W
    Rigler, R
    [J]. JOURNAL OF BIOTECHNOLOGY, 2001, 86 (03) : 237 - 253
  • [10] Capillary tube resistive thermal cycling
    Friedman, NA
    Meldrum, DR
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (14) : 2997 - 3002