Kalman-Based Calibration Algorithm for AgaMatrix Continuous Glucose Monitoring System

被引:6
作者
Singh, Abhinoy Kumar [1 ,2 ]
Rebec, Mihailo V. [3 ]
Haidar, Ahmad [1 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ H3A 2B4, Canada
[2] IIT Indore, Dept Elect Engn, Indore 453552, India
[3] WaveForm Technol Inc, Wilsonville, OR 97070 USA
关键词
Glucose; Calibration; Kalman filters; Blood; Noise measurement; Current measurement; Estimation; Continuous glucose monitoring; glucose sensor; Kalman filter; parameter estimation; INTEGRAL EQUATIONS; DECONVOLUTION; ACCURACY; SENSORS; STATE;
D O I
10.1109/TCST.2020.3003450
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A continuous glucose monitoring system is composed of a glucose sensor and an estimation (calibration) algorithm. The glucose sensor is composed of an electrode that is inserted under the skin and generates a noisy electrical current in response to interstitial glucose levels. The relationship between the electrical current and the interstitial glucose levels varies between individuals and within the same individual (with sensor wear time). The estimation algorithm infers the glucose levels in the blood from the noisy electrical current signal and uses intermittent capillary glucose measurements to account for intra-and inter-individual variability. In this article, we propose a novel real-time Kalman filter-based estimation algorithm that is composed of three steps: 1) noise filtering step; 2) compartment matching step using sequential Kalman filter; and 3) parameters estimation step using the conventional Kalman filter. The initial estimate of the parameters and covariance matrix are extracted offline using a nonlinear cubature Kalman filter. Our algorithm is compared with four alternative algorithms using 20 sensor data sets. Each data set was generated over a seven-day sensor wear period, during which patients were tested on three in-clinic days (days 1, 4, and 7). The comparison is based on the mean absolute relative difference (MARD) between frequent reference glucose measurements and the sensor glucose levels. MARD for days 1, 4, and 7 were 10.3%, 10.7%, and 11.9% for our algorithm and 12.46%, 15.75%, and 14.17% for the alternative algorithm, respectively. Our algorithm is currently being integrated into a commercial continuous glucose monitoring system (AgaMatrix, Inc., Salem, NH, USA).
引用
收藏
页码:1257 / 1267
页数:11
相关论文
共 50 条
  • [41] Continuous glucose monitoring (CGM) system based on protein hydrogel anti-biofouling coating for long-term accurate and point-of-care glucose monitoring
    Tong, Xinglai
    Jiang, Tuohao
    Yang, Jiaying
    Song, Ying
    Ao, Qi
    Tang, Jun
    Zhang, Ling
    BIOSENSORS & BIOELECTRONICS, 2025, 277
  • [42] Impact of Body Composition on the Accuracy of a Medtronic Guardian Continuous Glucose Monitoring System
    Abraham, Mary B.
    Smith, Grant J.
    Choo, Ace Y. L.
    de Bock, Martin
    Davis, Elizabeth A.
    Jones, Timothy W.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (08) : 549 - 553
  • [43] Real-time intradermal continuous glucose monitoring using a minimally invasive microneedle-based system
    Ribet, Federico
    Stemme, Goran
    Roxhed, Niclas
    BIOMEDICAL MICRODEVICES, 2018, 20 (04)
  • [44] A Critical Discussion of Alert Evaluations in the Context of Continuous Glucose Monitoring System Performance
    Pleus, Stefan
    Eichenlaub, Manuel
    Waldenmaier, Delia
    Freckmann, Guido
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (04): : 847 - 856
  • [45] Optimization of a Ferrocene Carboxylic Acid-Based Enzymatic Glucose Sensor for Continuous Glucose Monitoring
    Nayak, Kavya K.
    Bhat, Navakanta
    IEEE SENSORS JOURNAL, 2024, 24 (20) : 33299 - 33308
  • [46] Improved RAIM Algorithm Based on Kalman Innovation Monitoring Method
    Yang, Zhengnan
    Li, Huaijian
    Du, Xiaojing
    CHINA SATELLITE NAVIGATION CONFERENCE (CSNC) 2018 PROCEEDINGS, VOL I, 2018, 497 : 759 - 768
  • [47] Non-Invasive Continuous Glucose Monitoring with Multi-Sensor Systems: A Monte Carlo-Based Methodology for Assessing Calibration Robustness
    Zanon, Mattia
    Sparacino, Giovanni
    Facchinetti, Andrea
    Talary, Mark S.
    Mueller, Martin
    Caduff, Andreas
    Cobelli, Claudio
    SENSORS, 2013, 13 (06): : 7279 - 7295
  • [48] ONLINE CALIBRATION OF A COMPUTERIZED BIOSENSOR SYSTEM FOR CONTINUOUS MEASUREMENTS OF GLUCOSE AND LACTATE
    KYROLAINEN, M
    HAKANSON, H
    MATTIASSON, B
    BIOTECHNOLOGY AND BIOENGINEERING, 1995, 45 (02) : 122 - 128
  • [49] Kalman-based velocity-free trajectory tracking control of an underactuated aerial vehicle with unknown system dynamics
    Reis, Joel
    Yu, Gan
    Silvestre, Carlos
    AUTOMATICA, 2023, 155
  • [50] Noise Reduction in Continuous Blood Glucose Sensor using Physiology based Kalman Filter for Artificial Pancreatic System
    Bidarahalli, Nitin
    Rajesh, M.
    Velappan, Vijayan
    Krishnan, Palani Thanaraj
    2018 3RD INTERNATIONAL CONFERENCE ON CIRCUITS, CONTROL, COMMUNICATION AND COMPUTING (I4C), 2018,