Kalman-Based Calibration Algorithm for AgaMatrix Continuous Glucose Monitoring System

被引:6
作者
Singh, Abhinoy Kumar [1 ,2 ]
Rebec, Mihailo V. [3 ]
Haidar, Ahmad [1 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ H3A 2B4, Canada
[2] IIT Indore, Dept Elect Engn, Indore 453552, India
[3] WaveForm Technol Inc, Wilsonville, OR 97070 USA
关键词
Glucose; Calibration; Kalman filters; Blood; Noise measurement; Current measurement; Estimation; Continuous glucose monitoring; glucose sensor; Kalman filter; parameter estimation; INTEGRAL EQUATIONS; DECONVOLUTION; ACCURACY; SENSORS; STATE;
D O I
10.1109/TCST.2020.3003450
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A continuous glucose monitoring system is composed of a glucose sensor and an estimation (calibration) algorithm. The glucose sensor is composed of an electrode that is inserted under the skin and generates a noisy electrical current in response to interstitial glucose levels. The relationship between the electrical current and the interstitial glucose levels varies between individuals and within the same individual (with sensor wear time). The estimation algorithm infers the glucose levels in the blood from the noisy electrical current signal and uses intermittent capillary glucose measurements to account for intra-and inter-individual variability. In this article, we propose a novel real-time Kalman filter-based estimation algorithm that is composed of three steps: 1) noise filtering step; 2) compartment matching step using sequential Kalman filter; and 3) parameters estimation step using the conventional Kalman filter. The initial estimate of the parameters and covariance matrix are extracted offline using a nonlinear cubature Kalman filter. Our algorithm is compared with four alternative algorithms using 20 sensor data sets. Each data set was generated over a seven-day sensor wear period, during which patients were tested on three in-clinic days (days 1, 4, and 7). The comparison is based on the mean absolute relative difference (MARD) between frequent reference glucose measurements and the sensor glucose levels. MARD for days 1, 4, and 7 were 10.3%, 10.7%, and 11.9% for our algorithm and 12.46%, 15.75%, and 14.17% for the alternative algorithm, respectively. Our algorithm is currently being integrated into a commercial continuous glucose monitoring system (AgaMatrix, Inc., Salem, NH, USA).
引用
收藏
页码:1257 / 1267
页数:11
相关论文
共 50 条
  • [31] Design of a Real-time Self-adjusting Calibration Algorithm to Improve the Accuracy of Continuous Blood Glucose Monitoring
    Jia, Ziru
    Huang, Lijuan
    Liu, Hongying
    Huang, Yonghong
    Li, Wang
    Pi, Xitian
    Zheng, Xiaolin
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2020, 190 (04) : 1163 - 1176
  • [32] A Photoacoustics based Continuous Non-Invasive Blood Glucose Monitoring System
    Pai, Praful P.
    Sanki, Pradyut K.
    Banerjee, Swapna
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 106 - 111
  • [33] A Low Power Miniaturized CMOS-Based Continuous Glucose Monitoring System
    Croce, Robert A., Jr.
    Vaddiraju, Santhisagar
    Legassey, Allen
    Wang, Yan
    Burgess, Diane
    Papadimitrakopoulos, Fotios
    Jain, Faquir C.
    2013 IEEE INTERNATIONAL CONFERENCE ON BODY SENSOR NETWORKS (BSN), 2013,
  • [34] Kalman-based strategies for Fault Detection and Identification (FDI): Extensions and critical evaluation for a buffer tank system
    Villez, Kris
    Srinivasan, Babji
    Rengaswamy, Raghunathan
    Narasimhan, Shankar
    Venkatasubramanian, Venkat
    COMPUTERS & CHEMICAL ENGINEERING, 2011, 35 (05) : 806 - 816
  • [35] Generalization of a Deep Learning Model for Continuous Glucose Monitoring-Based Hypoglycemia Prediction: Algorithm Development and Validation Study
    Shao, Jian
    Pan, Ying
    Kou, Wei-Bin
    Feng, Huyi
    Zhao, Yu
    Zhou, Kaixin
    Zhong, Shao
    JMIR MEDICAL INFORMATICS, 2024, 12
  • [36] Continuous glucose monitoring system in the screening of glucose disorders in cystic fibrosis
    Martin-Frias, M.
    Lamas Ferreiro, A.
    Colino Alcol, E.
    Alvarez Gomez, M. A.
    Yelmo Valverde, R.
    Barrio Castellanos, R.
    ANALES DE PEDIATRIA, 2009, 70 (02): : 120 - 125
  • [37] The Role of Continuous Glucose Monitoring System Profiles in Diabetes
    Monnier, L.
    Colette, C.
    Owens, D.
    DIABETES STOFFWECHSEL UND HERZ, 2008, 17 : S17 - S22
  • [38] Non-enzymatic continuous glucose monitoring system
    Moore, Sean
    You, Byoung Hee
    Kim, Namwon
    Park, Taehyun
    Song, In-Hyouk
    MICRO & NANO LETTERS, 2018, 13 (08): : 1079 - 1084
  • [39] The use of a continuous glucose monitoring system in hypoglycemic disorders
    Conrad, SC
    Mastrototaro, JJ
    Gitelman, SE
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2004, 17 (03) : 281 - 288
  • [40] Wearable microdialysis system for continuous in vivo monitoring of glucose
    Vering, T
    Adam, S
    Drewer, H
    Dumschat, C
    Steinkuhl, R
    Schulze, A
    Siegel, EG
    Knoll, M
    ANALYST, 1998, 123 (07) : 1605 - 1609