Kalman-Based Calibration Algorithm for AgaMatrix Continuous Glucose Monitoring System

被引:6
作者
Singh, Abhinoy Kumar [1 ,2 ]
Rebec, Mihailo V. [3 ]
Haidar, Ahmad [1 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ H3A 2B4, Canada
[2] IIT Indore, Dept Elect Engn, Indore 453552, India
[3] WaveForm Technol Inc, Wilsonville, OR 97070 USA
关键词
Glucose; Calibration; Kalman filters; Blood; Noise measurement; Current measurement; Estimation; Continuous glucose monitoring; glucose sensor; Kalman filter; parameter estimation; INTEGRAL EQUATIONS; DECONVOLUTION; ACCURACY; SENSORS; STATE;
D O I
10.1109/TCST.2020.3003450
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A continuous glucose monitoring system is composed of a glucose sensor and an estimation (calibration) algorithm. The glucose sensor is composed of an electrode that is inserted under the skin and generates a noisy electrical current in response to interstitial glucose levels. The relationship between the electrical current and the interstitial glucose levels varies between individuals and within the same individual (with sensor wear time). The estimation algorithm infers the glucose levels in the blood from the noisy electrical current signal and uses intermittent capillary glucose measurements to account for intra-and inter-individual variability. In this article, we propose a novel real-time Kalman filter-based estimation algorithm that is composed of three steps: 1) noise filtering step; 2) compartment matching step using sequential Kalman filter; and 3) parameters estimation step using the conventional Kalman filter. The initial estimate of the parameters and covariance matrix are extracted offline using a nonlinear cubature Kalman filter. Our algorithm is compared with four alternative algorithms using 20 sensor data sets. Each data set was generated over a seven-day sensor wear period, during which patients were tested on three in-clinic days (days 1, 4, and 7). The comparison is based on the mean absolute relative difference (MARD) between frequent reference glucose measurements and the sensor glucose levels. MARD for days 1, 4, and 7 were 10.3%, 10.7%, and 11.9% for our algorithm and 12.46%, 15.75%, and 14.17% for the alternative algorithm, respectively. Our algorithm is currently being integrated into a commercial continuous glucose monitoring system (AgaMatrix, Inc., Salem, NH, USA).
引用
收藏
页码:1257 / 1267
页数:11
相关论文
共 50 条
  • [1] Enhanced Algorithm for glucose estimation using the Continuous Glucose Monitoring System
    Leal, Yenny
    Garcia-Gabin, Winston
    Bondia, Jorge
    Esteve, Eduardo
    Ricart, Wifredo
    Fernandez-Real, Jose-Manuel
    Vehi, Josep
    MEDICAL SCIENCE MONITOR, 2010, 16 (06): : MT51 - MT58
  • [2] Calibration algorithms for continuous glucose monitoring systems based on interstitial fluid sensing
    Sun, Tianyi
    Liu, Jentsai
    Chen, Ching Jung
    BIOSENSORS & BIOELECTRONICS, 2024, 260
  • [3] Speech Enhancement Using a Kalman-based Normalized LMS Algorithm
    Mahmoodzadeh, A.
    Abutalebi, H. R.
    Agahi, H.
    2008 INTERNATIONAL SYMPOSIUM ON TELECOMMUNICATIONS, VOLS 1 AND 2, 2008, : 555 - +
  • [4] A Multistep Algorithm for Processing and Calibration of Microdialysis Continuous Glucose Monitoring Data
    Mahmoudi, Zeinab
    Johansen, Mette Dencker
    Christiansen, Jens Sandahl
    Hejlesen, Ole Kristian
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (10) : 825 - 835
  • [5] Biosensor system for continuous glucose monitoring in fish
    Yonemori, Yuki
    Takahashi, Eiji
    Ren, Huifeng
    Hayashi, Tetsuhito
    Endo, Hideaki
    ANALYTICA CHIMICA ACTA, 2009, 633 (01) : 90 - 96
  • [6] Optimal Continuous Glucose Monitoring Sensor Calibration for Patients with Type 1 Diabetes
    Zhang, Xiaoran
    Zhang, Wan
    Cao, Yongtong
    Shi, Dawei
    Shi, Ling
    2019 IEEE 28TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2019, : 617 - 622
  • [7] Kalman-based Fault-tolerant Control System for Aeroengines
    Liu, Xiaofeng
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 5085 - 5088
  • [8] A Kalman-based Doppler tracking algorithm for underwater acoustic spread spectrum communications
    Sun, Dajun
    Hong, Xiaoping
    Cui, Hongyu
    APPLIED ACOUSTICS, 2022, 185
  • [9] A Fast Continuous Self-Calibration Method for FOG Rotational Inertial Navigation System Based on Invariant Extended Kalman Filter
    Li, Jun
    Zhang, Shifeng
    Yang, Huabo
    Jiang, Zhenyu
    Bai, Xibin
    IEEE SENSORS JOURNAL, 2023, 23 (03) : 2456 - 2469
  • [10] Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives
    Acciaroli, Giada
    Vettoretti, Martina
    Facchinetti, Andrea
    Sparacino, Giovanni
    BIOSENSORS-BASEL, 2018, 8 (01):