The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters

被引:49
作者
De Deene, Y.
Pittomvils, G.
Visalatchi, S.
机构
[1] State Univ Ghent Hosp, Radiotherapy Dept P7, B-9000 Ghent, Belgium
[2] Shree Krishna Hosp, MS Patel Canc Ctr, Dept Radiat Oncol, Karamsad 388325, Gujarat, India
[3] Med Res Ctr, Karamsad 388325, Gujarat, India
关键词
D O I
10.1088/0031-9155/52/10/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polymer gel dosimeters offer a wide range of applications in the three-dimensional verification of complex radiation dose distributions such as in intensity-modulated radiotherapy (IMRT). With the release of polymer gel dosimeters that can be fabricated in normal atmospheric ('normoxic') conditions, the gel manufacturing process has been significantly simplified. Gel dosimeters are calibrated by use of a series of calibration vials irradiated with known doses or by use of a calibration phantom with a known dose distribution. The overall accuracy of the polymer gel dosimeters is determined by different dosimetric properties. In this study, we show the influence of the temperature history during storage of the gel dosimeter on the dose response curve for two gel dosimeters using the monomers acrylamide/N,N'-methylene-bis-acrylamide (nPAG) and methacrylic acid (nMAG) respectively and bis[tetrakis(hydroxymethyl)phosphonium]sulphate (THP) as antioxidant in both gel dosimeters. This study reveals that differences in temperature history after fabrication of normoxic polymer gel dosimeters may compromise the dosimetric accuracy. It was found that the acrylamide based gel dosimeter (nPAG) is less dependent on the post-manufacture temperature history than the methacrylic acid based gel dosimeter (nMAG). The importance of an equal temperature history for the gel dosimeter and calibration vials is emphasized by this study. A reproducibility study has also been performed on the nPAG gel dosimeter when additional efforts are made to control the temperature changes upon cooling.
引用
收藏
页码:2719 / 2728
页数:10
相关论文
共 7 条
  • [1] The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels
    De Deene, Y
    Vergote, K
    Claeys, C
    De Wagter, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (03) : 653 - 673
  • [2] Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer
    De Deene, Y
    De Wagter, C
    Van Duyse, B
    Derycke, S
    De Neve, W
    Achten, E
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) : 283 - 291
  • [3] Optimization of multiple spin-echo sequences for 3D polymer gel dosimetry
    De Deene, Y.
    Baldock, C.
    [J]. 2002, Institute of Physics Publishing (47)
  • [4] De Deene Y, 2000, PHYS MED BIOL, V45, P859, DOI 10.1088/0031-9155/45/4/304
  • [5] De Deene YH, 2001, PHYS MED BIOL, V46, P2801, DOI 10.1088/0031-9155/46/11/304
  • [6] The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy
    Martens, C
    De Wagter, C
    De Neve, W
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) : 2519 - 2530
  • [7] Effects of glass and backscatter on measurement of absorbed dose in polyacrylamide gel (PAG) dosimeters
    Michael, GJ
    Henderson, CJ
    Nitschke, K
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) : N133 - N138