Improvements in Parallel Imaging Accelerated Functional MRI Using Multiecho Echo-Planar Imaging

被引:21
作者
Schmiedeskamp, Heiko [1 ,2 ,3 ]
Newbould, Rexford D. [1 ,4 ]
Pisani, Laura J. [1 ]
Skare, Stefan [1 ]
Glover, Gary H. [1 ]
Pruessmann, Klaas P. [2 ,3 ]
Bammer, Roland [1 ]
机构
[1] Stanford Univ, Dept Radiol, Lucas Ctr, Stanford, CA 94305 USA
[2] ETH, Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[4] GSK Clin Imaging Ctr, London, England
基金
美国国家卫生研究院;
关键词
fMRI; parallel imaging; multiecho EPI; temporal SNR; image distortions; signal dropout; BOLD-CONTRAST SENSITIVITY; REAL-TIME FMRI; SINGLE-SHOT; SENSORY STIMULATION; BRAIN ACTIVITY; SIGNAL CHANGES; VISUAL-CORTEX; EPI; ENHANCEMENT; RESOLUTION;
D O I
10.1002/mrm.22222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multiecho echo-planar imaging (EPI) was implemented for blood-oxygenation-level-dependent functional MRI at 1.5 T and compared to single-echo EPI with and without parallel imaging acceleration. A time-normalized breath-hold task using a block design functional MRI protocol was carried out in combination with up to four echo trains per excitation and parallel imaging acceleration factors R = 1-3. Experiments were conducted in five human subjects, each scanned in three sessions. Across all reduction factors, both signal-to-fluctuation-noise ratio and the total number of activated voxels were significantly lower using a single-echo EPI pulse sequence compared with the multiecho approach. Signal-to-fluctuation-noise ratio and total number of activated voxels were also considerably reduced for nonaccelerated conventional single-echo EPI when compared to three-echo measurements with R = 2. Parallel imaging accelerated multiecho EPI reduced geometric distortions and signal dropout, while it increased blood-oxygenation-level-dependent signal sensitivity all over the brain, particularly in regions with short underlying T. Thus, the presented method showed multiple advantages over conventional single-echo EPI for standard blood-oxygenation-level-dependent functional MRI experiments. Magn Reson Med 63:959-969, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:959 / 969
页数:11
相关论文
共 37 条
[31]  
SCHMIEDESKAMP H, 2008, P 16 ANN M ISMRM TOR, P2368
[32]   Functional imaging by I0- and T2*-parameter mapping using multi-image EPI [J].
Speck, O ;
Hennig, J .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) :243-248
[33]   Calibration of BOLD fMRI using breath holding reduces group variance during a cognitive task [J].
Thomason, Moriah E. ;
Foland, Lara C. ;
Glover, Gary H. .
HUMAN BRAIN MAPPING, 2007, 28 (01) :59-68
[34]  
VANDEMOORTELE PF, 2008, P 16 SCI M INT SOC M, P2464
[35]   Single-shot compensation of image optimization using multi-echo EPI distortions and BOLD contrast for real-time fMRI [J].
Weiskopf, N ;
Klose, U ;
Birbaumer, N ;
Mathiak, K .
NEUROIMAGE, 2005, 24 (04) :1068-1079
[36]   Potential and feasibility of parallel MRI at high field [J].
Wiesinger, Florian ;
Van de Moortele, Pierre-Francois ;
Adriany, Gregor ;
De Zanche, Nicola ;
Ugurbil, Kamil ;
Pruessmann, Klaas P. .
NMR IN BIOMEDICINE, 2006, 19 (03) :368-378
[37]   Color-word matching stroop task:: Separating interference and response conflict [J].
Zysset, S ;
Müller, K ;
Lohmann, G ;
von Cramon, DY .
NEUROIMAGE, 2001, 13 (01) :29-36