Focusing of synchrotron radiation with polycapillary optics

被引:19
作者
Hofmann, FA [1 ]
Freinberg-Trufas, CA [1 ]
Owens, SM [1 ]
Padiyar, SD [1 ]
MacDonald, CA [1 ]
机构
[1] SUNY Albany, Ctr Xray Opt, Albany, NY 12222 USA
关键词
X-ray optics; polycapillary X-ray optics; synchrotron optics;
D O I
10.1016/S0168-583X(97)00541-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Polycapillary optics are arrays of thousands of hollow capillary tubes. Focal spots are produced from the overlap of outputs from multiple channels at distances of 10-100 mm from the output of the optic. Synchrotron focusing was performed with two polycapillary X-ray optics. The spot size for the monolithic optic was 80 mu m, which yielded a measured gain in photon flux through a 350 mu m pinhole of nearly 100. Gains up to an order of magnitude larger are expected for smaller pinholes. White beam focusing was also demonstrated. (C) 1997 Published by Elsevier Science B.V.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 21 条
[11]  
Macdonald C A, 1996, J Xray Sci Technol, V6, P32, DOI [10.1006/jxra.1996.0002, 10.3233/XST-1996-6102]
[12]  
MACDONALD CA, 1995, P SOC PHOTO-OPT INS, V2519, P186, DOI 10.1117/12.211905
[13]  
MACDONALD CA, 1993, SPIE P, V2011, P275
[14]  
OWENS SM, 1996, SPIE P, V2859, P200
[15]   Synchrotron white beam thermal loading on polycapillary X-ray optics [J].
Rath, BK ;
Hagelberg, FB ;
Homan, BE ;
MacDonald, CA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 401 (2-3) :421-428
[16]  
RATH BK, 1995, P SOC PHOTO-OPT INS, V2519, P207, DOI 10.1117/12.211907
[17]   FOCUSING OF SYNCHROTRON RADIATION USING TAPERED GLASS-CAPILLARIES [J].
THIEL, DJ ;
STERN, EA ;
BILDERBACK, DH ;
LEWIS, A .
PHYSICA B, 1989, 158 (1-3) :314-316
[18]   SUBMICRON CONCENTRATION AND CONFINEMENT OF HARD X-RAYS [J].
THIEL, DJ ;
BILDERBACK, DH ;
LEWIS, A ;
STERN, EA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (03) :597-600
[19]   CONCENTRATION OF SYNCHROTRON BEAMS BY MEANS OF MONOLITHIC POLYCAPILLARY X-RAY OPTICS [J].
ULLRICH, JB ;
HUANG, KG ;
OWENS, SM ;
ALOISI, DC ;
HOFMANN, FA ;
GAO, N ;
KLOTZKO, IL ;
GIBSON, WM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 364 (02) :362-367
[20]   POTENTIAL FOR CONCENTRATION OF SYNCHROTRON BEAMS WITH CAPILLARY OPTICS [J].
ULLRICH, JB ;
GIBSON, WM ;
GUBAREV, MV ;
MACDONALD, CA ;
XIAO, QF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) :401-406