Late complications of tissue glues in aortic surgery

被引:113
作者
Bingley, JA [1 ]
Gardner, MAH [1 ]
Stafford, EG [1 ]
Mau, TK [1 ]
Pohlner, PG [1 ]
Tam, RKW [1 ]
Jalali, H [1 ]
Tesar, PJ [1 ]
O'Brien, MF [1 ]
机构
[1] Prince Charles Hosp, Dept Cardiothorac Surg, Chermside, Qld 4032, Australia
关键词
D O I
10.1016/S0003-4975(00)01250-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Tissue glues are used in cardiothoracic surgery as an adjunct to operative procedures where tissues are frail, as in aortic dissection, or where added hemostasis is required. This study was undertaken to review the use of tissue glue in our institution over a 5.5-year period. The aim of the study was to identify any potentially glue-related complications. Methods. A review of tissue glue use for the period from January 1993 to September 1998 was performed and pre-, intra; and postoperative parameters were collected. After some unusual surgical findings, of special interest was a range of pathology found at late reoperation. Results. A total of 67 eases of tissue glue use were identified, with the majority of operations for type A dissection (76%). There were two intraoperative deaths. Twenty-seven of 65 patients (41%) required 29 further open chest operations; of these, 17 were for acute problems of bleeding or tamponade. Twelve patients (18%) underwent late reoperations months to years later. Nine of these patients, concentrated in two operative groups (7 patients with aortic valve resuspension and 2 patients who had undergone "switch" operations for transposition of great vessels), displayed complications related to the application of gelatin-resorcinol-formaldehyde (GRF) tissue glue. Conclusions. Indications for tissue glues in cardiothoracic surgery must be carefully considered. We have reviewed our use of some tissue glues in acute type A. aortic dissections and in pediatric cardiac patients and have discontinued the use of GRF glues because of unsatisfactory long-term complications. (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:1764 / 1768
页数:5
相关论文
共 21 条
  • [1] BIOPHYSICAL PROPERTIES OF THE GELATIN-RESORCINOL-FORMALDEHYDE GLUTARALDEHYDE ADHESIVE
    ALBES, JM
    KRETTEK, C
    HAUSEN, B
    ROHDE, R
    HAVERICH, A
    BORST, HG
    TATOOLES, CJ
    [J]. ANNALS OF THORACIC SURGERY, 1993, 56 (04) : 910 - 915
  • [2] Bachet J, 1997, J CARDIAC SURG, V12, P243
  • [3] EFFICIENT TISSUE GLUING IN AORTIC DISSECTION
    BORST, HG
    LAAS, J
    BUHNER, B
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1994, 8 (03) : 160 - 161
  • [4] EMBOLIZATION OF BIOLOGIC GLUE DURING REPAIR OF AORTIC DISSECTION
    CARREL, T
    MAURER, M
    TKEBUCHAVA, T
    NIEDERHAUSER, U
    SCHNEIDER, J
    TURINA, MI
    [J]. ANNALS OF THORACIC SURGERY, 1995, 60 (04) : 1118 - 1120
  • [5] THE IMPACT OF GELATIN-RESORCINOL GLUE ON AORTIC TISSUE - A HISTOMORPHOLOGIC EVALUATION
    ENNKER, J
    ENNKER, IC
    SCHOON, D
    SCHOON, HA
    DORGE, S
    MEISSLER, M
    RIMPLER, M
    HETZER, R
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 20 (01) : 34 - 43
  • [6] FABIANI JN, 1989, CIRCULATION, V80, P264
  • [7] FANN JI, 1991, J THORAC CARDIOV SUR, V102, P62
  • [8] The use of gelatin-resorcin-formalin glue in acute aortic dissection type A
    Fukunaga, S
    Karck, M
    Harringer, W
    Cremer, J
    Rhein, C
    Haverich, A
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (05) : 564 - 569
  • [9] Goossens D, 1998, CARDIOVASC SURG, V6, P76
  • [10] GRIFFIN S, 1990, J CARDIOVASC SURG, V31, P239