Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome

被引:129
|
作者
Meurice, JC [1 ]
Marc, I [1 ]
Series, F [1 ]
机构
[1] HOP LAVAL,CTR PNEUMOL,UNITE RECH,ST FOY,PQ G1V 4G5,CANADA
关键词
D O I
10.1164/ajrccm.153.2.8564134
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The auto-CPAP (Morphee Plus) is characterized by its ability to modify the positive-pressure level applied during the night for the presence or absence of sleep-induced respiratory disorders. The aim of the study was to compare the efficacy of this new mode of CPAP therapy with that of conventional constant-CPAP in the treatment of sleep apnea/hypopnea syndrome (SAHS). Sixteen patients with SAHS were randomly allocated to two groups that were paired for age, apnea/hypopnea index, and mean sleep latency. In the auto-CPAP group, the pressure level could change within fixed limits in both directions (+2 to -4 cm H2O) of the previously determined effective pressure level (Peff). In the constant-CPAP group, patients used the same apparatus (Morphee Plus) in a constant mode at Peff level. At the beginning of the study, the Peff level was determined during a polysomnographic recording. Daytime vigilance was measured subjectively by a standardized questionnaire and objectively by the maintenance of wakefulness test (MWT); Trailmaking tests (TMT) were used to evaluate cognitive functions. After 3 wk of home CPAP therapy, a control sleep study was done with the CPAP machine used in the protocol, and daytime vigilance and cognitive function tests were obtained. Baseline sleep and nocturnal breathing disorders characteristics did not differ between the two groups, and daytime vigilance and cognitive function abnormalities were similarily altered. In both groups, the apnea/hypopnea index was within normal range at the final CPAP sleep study. In the auto-CPAP group, 49.3 +/- 14.9% (mean +/- SD) of home treatment time was spent at a pressure less than or equal to Peff. Home amount of use estimated by the number of sleeping hours with a positive pressure applied was 6.5 +/- 1.0 h in the auto-CPAP group and 5.1 +/- 1.1 h in the constant-CPAP group (p = 0.02). During the control CPAP sleep study, the positive pressure level was significantly lower during Stage III-IV than during the other sleep stages (p = 0.004). The improvement in the MWT and the TMT observed with CPAP therapy was identical in both groups. We conclude that (1) the amount of use during CPAP treatment is higher with auto-CPAP than with constant-CPAP, and (2) Morphee + auto-CPAP is as efficient as conventional CPAP in correcting nocturnal breathing disorders, daytime sleepiness, and cognitive impairment in SAHS.
引用
收藏
页码:794 / 798
页数:5
相关论文
共 50 条
  • [1] Is treatment of obstructive sleep apnea syndrome with auto-CPAP useful?
    Sériès, F
    SLEEP, 2000, 23 : S161 - S165
  • [2] Auto-CPAP (APAP) for treatment of obstructive sleep apnea
    Berry, RB
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1542 - 1543
  • [3] Auto CPAP in the treatment of sleep apnea hypopnea syndrome
    Series, F
    SLEEP, 1996, 19 (10) : S281 - S283
  • [4] Efficacy of a FOT-based auto-CPAP device for the treatment of obstructive sleep apnea
    Treml, Marcel
    Herkenrath, Simon Dominik
    Anduleit, Norbert
    Pietruska, Karin
    Schwaibold, Matthias
    Randerath, Winfried J.
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [5] The Automatic Algorithm of the Auto-CPAP Device as a Tool for the Assessment of the Treatment Efficacy of CPAP in Patients with Moderate and Severe Obstructive Sleep Apnea Syndrome
    Brajer-Luftmann, Beata
    Trafas, Tomasz
    Mardas, Marcin
    Stelmach-Mardas, Marta
    Batura-Gabryel, Halina
    Piorunek, Tomasz
    LIFE-BASEL, 2022, 12 (09):
  • [6] Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea
    Alberto Nigro, Carlos
    Gonzalez, Sergio
    Arce, Anabella
    Rosario Aragone, Maria
    Nigro, Luciana
    SLEEP AND BREATHING, 2015, 19 (02) : 569 - 578
  • [7] Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea
    Carlos Alberto Nigro
    Sergio González
    Anabella Arce
    María Rosario Aragone
    Luciana Nigro
    Sleep and Breathing, 2015, 19 : 569 - 578
  • [8] Efficacy and adherence of auto-CPAP therapy in patients with obstructive sleep apnea: a prospective study
    Hang Dinh-Thi-Dieu
    Anh Vo-Thi-Kim
    Huong Tran-Van
    Sy Duong-Quy
    MULTIDISCIPLINARY RESPIRATORY MEDICINE, 2020, 15
  • [9] Evaluation of an auto-CPAP device for treatment of obstructive sleep apnoea
    Ficker, JH
    Wiest, GH
    Lehnert, G
    Wiest, B
    Hahn, EG
    THORAX, 1998, 53 (08) : 643 - 648
  • [10] High Accuracy of Auto-CPAP for Obstructive Sleep Apnea in Acute Stroke Patients
    Camilo, Millene
    Eckeli, Alan
    Barreira, Clara
    Machado, Luis
    Sander, Heidi
    Leite, Joao
    Fernandes, Regina
    Pontes-Neto, Octavio M.
    STROKE, 2018, 49