Study of Electric Field Distribution on 22kV Insulator under Three Phase Energisation

被引:0
|
作者
Liang, Mu [1 ]
Wong, K. L. [1 ]
机构
[1] RMIT Univ, Melbourne, Vic, Australia
来源
PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014) | 2014年
关键词
Electric field calculation; finite element method; composite insulators; three-phase system; CORONA;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Simulation of the electric field and potential distribution is widely performed in the design of high voltage composite insulators. This paper introduces and analysis of electric field distribution around the insulator under a 22kV high voltage AC (HVAC) transmission line. A two-dimensional model is built to calculate the electric field distribution in single phase system and another 2-D model is used to calculate the distribution under a three-phase HVAC transmission line. The effects of the metal ground pin are considered in the model and a comparison of the single phase system and three-phase system is given in the conclusion. The results show that electric field strength in a three-phase system is significant larger than a single phase system. The electric field fluxes are also affected by the ground pin and other two phases in a three-phase system.
引用
收藏
页码:140 / 143
页数:4
相关论文
共 50 条
  • [31] Analysis for Transient Electric Field Computation of GIS Basin Insulator Under Lightning Impulse Voltage
    Yang W.
    Zhu T.
    Tian Y.
    Ke Y.
    Zhu S.
    Yang X.
    Yang, Wei (hfut_mars@163.com), 2020, Science Press (46): : 807 - 814
  • [32] Electric field distribution around 400 kV line composite insulators in different connection conditions
    Bouhaouche, M.
    Mekhaldi, A.
    Teguar, M.
    DIELECTRIC MATERIALS AND APPLICATIONS, ISYDMA '2016, 2016, 1 : 71 - 74
  • [33] Influence of VFTO Characteristics on Electric Field Distribution of Basin-Type Insulator Using Transient Method
    Wu, Zehua
    Gong, Ao
    Zhu, Sijia
    Xie, Zongliang
    Guo, Zihao
    Peng, Zongren
    2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 39 - 42
  • [34] Study on Electric Field Distortion Effect by Linear Defects of Tri-post Insulator
    Wu, Zehua
    Wang, Haoran
    Tian, Huidong
    Cui, Boyuan
    Zhou, Shiyi
    Peng, Zongren
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 195 - 198
  • [35] Influence of the Material Parameters on the Electric Field Intensity Distribution of 10kV Cable Elbow Connector
    Guo, Qingfeng
    Xiong, Jun
    Dai, Nianqin
    Liao, Sizhuo
    Lu, Binxian
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [36] Computation and Analysis of the Electric Field Distribution and Voltage-Sharing Characteristics for 1000 kV Composite Tower
    Wang, Qingyu
    Yang, Xi
    Li, He
    Guo, Zihao
    Pengi, Zongren
    2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 1048 - 1051
  • [37] A study of the electric-field intensity of conductors of a 500-kV air line
    Trufanova N.M.
    Borodulina K.V.
    Dyatlov I.Y.
    Russian Electrical Engineering, 2017, 88 (11) : 706 - 708
  • [38] Study on Electric Field Distribution of Cage-type Rigid Jumper for 1000kV AC Ultra High Voltage Transmission Lines
    Li, Jing
    Peng, Zongren
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 77 - 80
  • [39] Investigation of leakage current and electric field of polymeric insulator with ring-shaped contamination under ice conditions
    Ghiasi, Zahra
    Faghihi, Faramarz
    Shayegani-Akmal, Amir Abbas
    ELECTRICAL ENGINEERING, 2022, 104 (04) : 2079 - 2089
  • [40] Theoretical Analysis, Simulation and Optimization of Electric Field on the Three-Phase Electrodynamic Screen
    Baqraf, Saeed A.
    Gondal, Mohammed A.
    Dastageer, Mohamed. A.
    Rao, Saleem
    Al-Aswad, Abdulaziz
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2025, 50 (01) : 597 - 610