Characterization of Hand Tendons Through High-Frequency Ultrasound Elastography

被引:18
作者
Chen, Pei-Yu [1 ]
Yang, Tai-Hua [1 ,2 ,3 ]
Kuo, Li-Chieh [4 ]
Shih, Cho-Chiang [1 ]
Huang, Chih-Chung [1 ,3 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan 70101, Taiwan
[2] Natl Cheng Kung Univ, Dept Orthoped, Tainan 70101, Taiwan
[3] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan 70101, Taiwan
[4] Natl Cheng Kung Univ, Dept Occupat Therapy, Tainan 70101, Taiwan
关键词
Hand tendon rehabilitation; hand tendon stiffness; high-frequency (HF) ultrasound elastography; shear wave velocity (SWV); tendon characterization; SHEAR-WAVE SPEED; HILBERT-HUANG TRANSFORM; CARPAL-TUNNEL PRESSURE; TRANSIENT ELASTOGRAPHY; ACHILLES-TENDON; FLEXOR TENDON; TIME-SERIES; VISCOELASTIC PROPERTIES; SONOGRAPHIC APPEARANCE; SOFT-TISSUE;
D O I
10.1109/TUFFC.2019.2938147
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Tendon stiffness plays an important role in the tendon healing process, and many studies have indicated that measuring the shear wave velocity (SWV) on tendons relates to their stiffness. Because the thickness of hand tendons is a few millimeters, high-resolution imaging is required for visualizing hand tissues. However, the resolution of current ultrasound elastography systems is insufficient. In this study, a high-frequency (HF) ultrasound elastography system is proposed for measuring the SWVs of hand tendons. The HF ultrasound elastography system uses an external vibrator to create shear waves on hand tendons. Then, it uses a 40-MHz HF ultrasound array transducer with ultrafast ultrasound imaging technology to measure the SWV for characterizing hand tendons. A handheld device that combines a transducer and a vibrator allows the user to scan hand tissues. The biases of HF ultrasound elastography were measured in gelatin phantom experiments and were less than 6 compared to standard mechanical testing approach. Human experiments showed the ability to use HF ultrasound elastography to distinguish different SWVs of hand tendons. The SWVs were 0.73 0.65 m/s and 1 0.54 m/s for flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP), respectively, and 0.52 0.14 m/s and 4.02 0.77 m/s for extensor tendon under stretch and contraction conditions, respectively. The simplicity and convenience of the HF ultrasound elastography system for measuring hand tendon stiffness make it a promising tool for evaluating the severity of hand injuries and the performance of rehabilitation after hand injuries.
引用
收藏
页码:37 / 48
页数:12
相关论文
共 60 条
[51]   Quantitative ultrasound mapping of regional variations in shear wave speeds of the aging Achilles tendon [J].
Slane, Laura Chernak ;
Martin, Jack ;
DeWall, Ryan ;
Thelen, Darryl ;
Lee, Kenneth .
EUROPEAN RADIOLOGY, 2017, 27 (02) :474-482
[52]   Middle-aged adults exhibit altered spatial variations in Achilles tendon wave speed [J].
Slane, Laura Chernak ;
DeWall, Ryan ;
Martin, Jack ;
Lee, Kenneth ;
Thelen, Darryl G. .
PHYSIOLOGICAL MEASUREMENT, 2015, 36 (07) :1485-1496
[53]   The use of sonoelastography to assess the recovery of stiffness after equine superficial digital flexor tendon injuries: A preliminary prospective longitudinal study of the healing process [J].
Tamura, N. ;
Nukada, T. ;
Kato, T. ;
Kuroda, T. ;
Kotoyori, Y. ;
Fukuda, K. ;
Kasashima, Y. .
EQUINE VETERINARY JOURNAL, 2017, 49 (05) :590-595
[54]   Sonoelastographic assessment of the age-related changes of the Achilles tendon [J].
Turan, Aynur ;
Teber, Mehmet Akif ;
Yakut, Zeynep Ilerisoy ;
Unlu, Havva Akmaz ;
Hekimoglu, Baki .
MEDICAL ULTRASONOGRAPHY, 2015, 17 (01) :58-61
[55]   Neurophysiological and Computational Principles of Cortical Rhythms in Cognition [J].
Wang, Xiao-Jing .
PHYSIOLOGICAL REVIEWS, 2010, 90 (03) :1195-1268
[56]   A non-invasive technique for estimating carpal tunnel pressure by measuring shear wave speed in tendon: A feasibility study [J].
Wang, Yuexiang ;
Qiang, Bo ;
Zhang, Xiaoming ;
Greenleaf, James F. ;
An, Kai-Nan ;
Amadio, Peter C. ;
Zhao, Chunfeng .
JOURNAL OF BIOMECHANICS, 2012, 45 (16) :2927-2930
[57]   Sonoelastographic imaging of interference patterns for estimation of the shear velocity of homogeneous biomaterials [J].
Wu, Z ;
Taylor, LS ;
Rubens, DJ ;
Parker, KJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06) :911-922
[58]   ULTRASONIC-IMAGING OF INTERNAL VIBRATION OF SOFT-TISSUE UNDER FORCED VIBRATION [J].
YAMAKOSHI, Y ;
SATO, J ;
SATO, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (02) :45-53
[59]   An integrated indenter-ARFI imaging system for tissue stiffness quantification [J].
Zhai, Liang ;
Palmeri, Mark L. ;
Bouchard, Richard R. ;
Nightingale, Roger W. ;
Nightingale, Kathryn R. .
ULTRASONIC IMAGING, 2008, 30 (02) :95-111
[60]   Evaluation of Elastic Stiffness in Healing Achilles Tendon After Surgical Repair of a Tendon Rupture Using In Vivo Ultrasound Shear Wave Elastography [J].
Zhang, Li-ning ;
Wan, Wen-bo ;
Wang, Yue-xiang ;
Jiao, Zi-yu ;
Zhang, Li-hai ;
Luo, Yu-kun ;
Tang, Pei-fu .
MEDICAL SCIENCE MONITOR, 2016, 22 :1186-1191