摘要
The methods to compute the counting efficiency of electron-capture nuclides in liquid scintillation counting have been improved in several previous studies. The main improvements comprise a more realistic treatment of the ejection of photoelectrons and subsequent rearrangement processes in the atomic shell as well as a more detailed atomic rearrangement model The latter was realized in the MICELLE code by means of a new stochastic approach This new model was also developed to account for energy deposits within micelles The recent improvements have now been combined in an updated version of the MICELLE code, which also makes the computation of the counting efficiency of complex decay schemes possible. In this paper, we describe and discuss recent extensions and improvements of the models and further corrections. The calculated counting efficiencies of selected radionuclides are compared with the experimental data obtained by liquid scintillation counting For the measurements, we use standard solutions, which were calibrated by other methods. (C) 2009 Elsevier Ltd All rights reserved.
引用
收藏
页码:1482 / 1488
页数:7
相关论文
共 24 条
  • [1] ORBITAL ELECTRON-CAPTURE BY NUCLEUS
    BAMBYNEK, W
    BEHRENS, H
    CHEN, MH
    CRASEMANN, B
    FITZPATRICK, ML
    LEDINGHAM, KWD
    GENZ, H
    MUTTERER, M
    INTEMANN, RL
    [J]. REVIEWS OF MODERN PHYSICS, 1977, 49 (01) : 77 - 221
  • [2] BE MM, 2004, BIPM MONOGRAPHIE, V5
  • [3] Radionuclide metrology using liquid scintillation counting
    Broda, Ryszard
    Cassette, Philippe
    Kossert, Karsten
    [J]. METROLOGIA, 2007, 44 (04) : S36 - S52
  • [4] Browne E., 1986, Table of Radioactive Isotopes
  • [5] MICELLE, the micelle size effect on the LS counting efficiency
    Carles, A. Grau
    [J]. COMPUTER PHYSICS COMMUNICATIONS, 2007, 176 (04) : 305 - 317
  • [6] EMILIA, the LS counting efficiency for electron-capture and capture-gamma emitters
    Carles, AG
    [J]. COMPUTER PHYSICS COMMUNICATIONS, 2006, 174 (01) : 35 - 46
  • [7] CARLES AG, 1994, COMPUT PHYS COMMUN, V79, P115, DOI 10.1016/0010-4655(94)90234-8
  • [8] The Compton source efficiency tracing method in liquid scintillation counting: A new standardization method using a TDCR counter with a Compton spectrometer
    Cassette, P.
    Do, Phuc
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 1026 - 1032
  • [9] Grau Malonda A., 1999, Free Parameter Models in Liquid Scintillation Counting
  • [10] GUNTHER E, 1998, INT J APPL RADIAT IS, V33, P371