Determination of wave speed and wave separation in the arteries using diameter and velocity

被引:98
作者
Feng, J. [1 ,2 ,3 ]
Khir, A. W. [1 ,2 ]
机构
[1] Brunel Univ, Brunel Inst Bioengn, Uxbridge UB8 3PH, Middx, England
[2] Brunel Univ, Sch Engn & Design, Uxbridge UB8 3PH, Middx, England
[3] Taiyuan Univ Technol, Sch Mech Engn, Taiyuan, Shanxi, Peoples R China
关键词
Noninvasive; Separated wave; Wave speed; Wave intensity analysis; Hemodynamic; Diameter; Velocity; INTENSITY ANALYSIS; CAROTID-ARTERY; PRESSURE; REFLECTIONS; AORTA;
D O I
10.1016/j.jbiomech.2009.09.046
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The determination of arterial wave speed and the separation of the forward and backward waves have been established using simultaneous measurements of pressure (P) and velocity (U). In this Work, we present a novel algorithm for the determination of local wave speed and the separation of waves using the simultaneous measurements of diameter (D) and U. The theoretical basis of this work is the solution of the I D equations of flow in elastic tubes. A relationship between D and U is derived, from which, local wave speed can be determined; C= +/- 0.5(dU(+/-)/dIn D-+/-). When only unidirectional waves are present, this relationship describes a linear relationship between In D and U. Therefore, constructing a In DU-loop should result in a straight line in the early part of the cycle when it is most probable that waves are running in the forward direction. Using this knowledge of wave speed, it is also possible to derive a set of equations to separate the forward and backward waves from the measured D and U waveforms. Once the forward and backward waveforms of D and U are established, we can calculate the energy carried by the forward and backward waves, in a similar way to that of wave intensity analysis. In this paper, we test the new algorithm in vitro and present results from data measured in the carotid artery of human and the ascending aorta of canine. We conclude that the new technique can be reproduced in vitro, and in different vessels of different species, in vivo. The new algorithm is easy to use to determine wave speed and separate D and U waveforms into their forward and backward directions. Using this technique has the merits of utilising noninvasive measurements, which would be useful in the clinical setting. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:455 / 462
页数:8
相关论文
共 24 条
[1]   Use of simultaneous pressure and velocity measurements to estimate arterial wave speed at a single site in humans [J].
Davies, JE ;
Whinnett, ZI ;
Francis, DP ;
Willson, K ;
Foale, RA ;
Malik, IS ;
Hughes, AD ;
Parker, KH ;
Mayet, J .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 290 (02) :H878-H885
[2]   On-line noninvasive one-point measurements of pulse wave velocity [J].
Harada, A ;
Okada, T ;
Niki, K ;
Chang, D ;
Sugawara, M .
HEART AND VESSELS, 2002, 17 (02) :61-68
[3]   Negative wave reflections in pulmonary arteries [J].
Hollander, EH ;
Wang, JJ ;
Dobson, GM ;
Parker, KH ;
Tyberg, JV .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 281 (02) :H895-H902
[4]   Simultaneous determination of wave speed and arrival time of reflected waves using the pressure-velocity loop [J].
Khir, A. W. ;
Swalen, M. J. P. ;
Feng, J. ;
Parker, K. H. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (12) :1201-1210
[5]   Wave intensity in the ascending aorta: effects of arterial occlusion [J].
Khir, AW ;
Parker, KH .
JOURNAL OF BIOMECHANICS, 2005, 38 (04) :647-655
[6]   Local and regional wave speed in the aorta: effects of arterial occlusion [J].
Khir, AW ;
Zambanini, A ;
Parker, KH .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (01) :23-29
[7]   Determination of wave speed and wave separation in the arteries [J].
Khir, AW ;
O'Brien, A ;
Gibbs, JSR ;
Parker, KH .
JOURNAL OF BIOMECHANICS, 2001, 34 (09) :1145-1155
[8]   Analysis of wave reflections in the arterial system using wave intensity: a novel method for predicting the timing and amplitude of reflected waves [J].
Koh, TW ;
Pepper, JR ;
DeSouza, AC ;
Parker, KH .
HEART AND VESSELS, 1998, 13 (03) :103-113
[9]   Wave intensity analysis of left ventricular filling [J].
Lanoye, LL ;
Vierendeels, JA ;
Segers, P ;
Verdonck, PR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (05) :862-867
[10]   Simultaneous assessment of diameter and pressure waveforms in the carotid artery [J].
Meinders, JM ;
Hoeks, APG .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (02) :147-154