State-Space Average-Value Model of 3-Phase 4-Wire Diode-Bridge Rectifier

被引:0
|
作者
Wei Keyin
Liu Dezhi
Ou Yangbing
Zhai Xiaofei
Yan Ming
机构
关键词
SYNCHRONOUS GENERATOR; LOAD; CONVERTERS; STABILITY; SYSTEMS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 3-phase 4-wire diode-bridge rectifier is one solution of the front-end DC power for high power multilevel inverter. The average-value model (AVM) of 3-phase 4-wire diode-bridge rectifier under continuous conduction mode (CCM) within generator-rectifier system is presented based on state-space averaging method. The AVM is validated using the corresponding switching model of rectifier by simulations in the Matlab/Simulink environment, and using a hardware test system composed of a synchronous generator and its 3-phase 4-wire diode-bridge rectifier load. The results show that the AVM can captures the key steady-state and transient characteristics of the rectifier, and the agreement of DC voltage between the AVM, the switching model, and the hardware circuit are well. The model presented herein can be used for modeling, impedance mapping, and stability assessment with small disturbance of such generator (transformer) -rectifier systems.
引用
收藏
页码:1617 / 1621
页数:5
相关论文
共 50 条
  • [31] Implementation of harmonic control for a 3-phase 4-wire inverter with harmonic-loaded neutral
    Ma, Yanyun
    Ellinger, Thomas
    Petzoldt, Juergen
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [32] Comparative Study of 3-phase 4-wire Converter Topologies for Active Thermal Control Techniques
    Nguyen M.H.
    Kwak S.
    Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (09): : 1066 - 1075
  • [33] Paralleling of 3-phase 4-wire DC-AC Inverters Using Repetitive Control
    Ainsworth, Nathan
    Murphree, Jerry
    APEC: 2009 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1- 4, 2009, : 116 - 120
  • [34] 3-Phase 4-Wire Hybrid Calculation - Analysis Method for Clustering Power Systems Philosophy
    Wirasanti, Paramet
    Ortjohann, Egon
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [35] Sensorless Unbalance Correction as an Ancillary Service for LV 4-Wire/3-Phase Power Converters
    Suarez-Gonzalez, Andres
    Garcia, Pablo
    Navarro-Rodriguez, Angel
    Villa, Geber
    Cano, Jose M.
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 4799 - 4805
  • [36] NEW CONTROL ALGORITHMS FOR SERIES AND SHUNT 3-PHASE 4-WIRE ACTIVE POWER FILTERS
    AREDES, M
    WATANABE, EH
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) : 1649 - 1656
  • [37] Novel Average Value Model for Faulty Three-Phase Diode Rectifier Bridges
    Rahnama, Mehdi
    Vahedi, Abolfazl
    Alikhani, Arta Mohammad
    Nahid-Mobarakeh, Babak
    Takorabet, Noureddine
    JOURNAL OF POWER ELECTRONICS, 2019, 19 (01) : 288 - 295
  • [38] Control for 3-phase 4-wire Active Power Filter Based on Synchronous Reference Frame
    Song, QingShuo
    ADVANCED MATERIALS AND ITS APPLICATION, 2012, 460 : 304 - 307
  • [39] Voltage and frequency controller for isolated asynchronous generators feeding 3-phase 4-wire loads
    Singh, Bhim
    Kasal, Gaurav Kumar
    2006 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-6, 2006, : 819 - +
  • [40] H∞ control of the neutral point in 3-phase 4-wire DC-AC converters
    Zhong, QC
    Green, TC
    Liang, J
    Weiss, G
    IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 520 - 525