Evaluation of affinity microcolumns containing human serum albumin for rapid analysis of drug-protein binding

被引:31
作者
Yoo, Michelle J. [1 ]
Schiel, John E. [1 ]
Hage, David S. [1 ]
机构
[1] Univ Nebraska, Dept Chem, Lincoln, NE 68588 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 20期
关键词
High-performance affinity chromatography; Affinity microcolumn; Frontal affinity chromatography; Frontal analysis; Zonal elution; Human serum albumin; Tryptophan; Warfarin; High-throughput screening; Drug-protein binding; PERFORMANCE LIQUID-CHROMATOGRAPHY; BIOINTERACTION CHROMATOGRAPHY; WARFARIN; PROBES; BIOSENSOR; SITES; PHASE; ACID;
D O I
10.1016/j.jchromb.2010.04.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study examined the use of affinity microcolumns as tools for the rapid analysis and high-throughput screening of drug-protein binding The protein used was immobilized human serum albumin (VISA) and the model analytes were warfarin and L-tryptophan, two solutes often used as site-specific probes for drug binding to Sudlow sites I and II of HSA, respectively The use of HSA microcolumns in binding studies was examined by using both zonal elution and frontal analysis formats The zonal elution studies were conducted by injecting the probe compounds onto HSA microcolumns of varying lengths while measuring the resulting retention factors, plate heights and peak asymmetries A decrease in the retention factor was noted when moving from longer to shorter column lengths while using a constant amount of injected solute However, this change could be corrected, in part, by determining the relative retention factor of a solute versus a reference compound injected onto the same microcolumn The plate height values were relatively consistent for all column lengths and gave an expected increase at higher linear velocities The peak asymmetries were similar for all columns up to I mL/min but shifted to larger values at higher flow rates and when using short microcolumns (e g, 1 mm length) The association equilibrium constants and number of binding sites estimated by frontal analysis for warfarin with HSA wet e consistent at the various column sizes that were tested and gave good agreement with previous literature values These results confirmed affinity microcolumns provide comparable results to those obtained with longer columns and can be used in the rapid analysis of drug-protein binding and in the high-throughput screening of such interactions (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:1707 / 1713
页数:7
相关论文
共 33 条
[21]   ALLOSTERIC AND COMPETITIVE DISPLACEMENT OF DRUGS FROM HUMAN SERUM-ALBUMIN BY OCTANOIC-ACID, AS REVEALED BY HIGH-PERFORMANCE LIQUID AFFINITY-CHROMATOGRAPHY, ON A HUMAN SERUM ALBUMIN-BASED STATIONARY PHASE [J].
NOCTOR, TAG ;
WAINER, IW ;
HAGE, DS .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (02) :305-315
[22]   Studies by biointeraction chromatography of binding by phenytoin metabolites to human serum albumin [J].
Ohnmacht, Corey M. ;
Chen, Shirley ;
Tong, Zenghan ;
Hage, David S. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 836 (1-2) :83-91
[23]  
Otagiri Masaki, 2005, Drug Metab Pharmacokinet, V20, P309, DOI 10.2133/dmpk.20.309
[24]   Development of an epoxy-based monolith used for the affinity capturing of Eschericha coli bacteria [J].
Peskoller, Caroline ;
Niessner, Reinhard ;
Seidel, Michael .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) :3794-3801
[25]  
Peters T., 1996, ALL ALBUM BIOCH GENE
[26]   DEVELOPMENT OF DIHYDRAZIDE-ACTIVATED SILICA SUPPORTS FOR HIGHPERFORMANCE AFFINITY-CHROMATOGRAPHY [J].
RUHN, PF ;
GARVER, S ;
HAGE, DS .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :9-19
[27]   Biosensor alternative: Frontal affinity chromatography [J].
Schriemer, DC .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :440A-448A
[28]   EQUILIBRIUM SATURATION CHROMATOGRAPHIC METHOD FOR STUDYING THE BINDING OF LIGANDS TO HUMAN-SERUM ALBUMIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INFLUENCE OF FATTY-ACIDS AND SODIUM DODECYL-SULFATE ON WARFARIN HUMAN SERUM-ALBUMIN BINDING [J].
SEBILLE, B ;
THUAUD, N ;
TILLEMENT, JP .
JOURNAL OF CHROMATOGRAPHY, 1979, 180 (01) :103-110
[29]   MEASUREMENT OF PROTEIN USING BICINCHONINIC ACID [J].
SMITH, PK ;
KROHN, RI ;
HERMANSON, GT ;
MALLIA, AK ;
GARTNER, FH ;
PROVENZANO, MD ;
FUJIMOTO, EK ;
GOEKE, NM ;
OLSON, BJ ;
KLENK, DC .
ANALYTICAL BIOCHEMISTRY, 1985, 150 (01) :76-85
[30]  
SUDLOW G, 1976, MOL PHARMACOL, V12, P1052