Comparison between invasive blood pressure and a non-invasive blood pressure monitor in anesthetized sheep

被引:14
作者
Almeida, Daniel [1 ]
Barletta, Michele [2 ]
Mathews, Lindsey [1 ]
Graham, Lynelle [1 ]
Quandt, Jane [3 ]
机构
[1] Univ Minnesota, Coll Vet Med, Dept Vet Clin Sci, St Paul, MN 55108 USA
[2] Univ Georgia, Coll Vet Med, Dept Large Anim Med, Athens, GA 30602 USA
[3] Univ Georgia, Coll Vet Med, Dept Small Anim Med & Surg, Athens, GA USA
基金
美国国家卫生研究院;
关键词
Anesthesia; Non-invasive blood pressure; Sheep; OVINE MODEL; RECONSTRUCTION; OSTEOARTHRITIS; ANESTHESIA; AGREEMENT; REPAIR; BONE; DOGS;
D O I
10.1016/j.rvsc.2014.10.004
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Monitoring blood pressure under general anesthesia in animals is important to prevent hypotension and poor tissue perfusion. Thirteen sheep were enrolled to evaluate the accuracy of the petMAP, a portable non-invasive blood pressure (NIBP) monitor. Animals were anesthetized with midazolam, fentanyl, ketamine, propofol and maintained with isoflurane in oxygen for ovariectomy. Invasive and non-invasive (petMAP) blood pressure measurements were recorded simultaneously every 5 minutes. Agreement between IBP and NIBP was assessed by evaluation of bias and 95% limits of agreement (LOA) using the Bland-Altman method and correlation coefficient. None of the measurements met the criteria for good agreement between invasive and non-invasive readings established by the Association for the Advancement of Medical Instrumentation. Systolic blood pressure readings obtained at the left thoracic limb site and mean blood pressure at the right pelvic limb site met the bias and LOA criteria established by the American College of Veterinary Internal Medicine. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:582 / 586
页数:5
相关论文
共 23 条
[1]   Agreement between directly measured blood pressure and pressures obtained with three veterinary-specific oscillometric units in cats [J].
Acierno, Mark J. ;
Seaton, Diana ;
Mitchell, Mark A. ;
da Cunha, Anderson .
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2010, 237 (04) :402-406
[2]  
[Anonymous], 2009, 810602 ANSIAAMIISO
[3]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[4]   Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs [J].
Bosiack, Ann P. ;
Mann, F. A. ;
Dodam, John R. ;
Wagner-Mann, Colette C. ;
Branson, Keith R. .
JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2010, 20 (02) :207-215
[5]  
Brown S, 2007, J VET INTERN MED, V21, P542, DOI 10.1892/0891-6640(2007)21[542:GFTIEA]2.0.CO
[6]  
2
[7]   Epicardial catheter-based ventricular reconstruction: a novel therapy for ischaemic heart failure with anteroapical aneurysm [J].
Cheng, Yanping ;
Aboodi, Michael S. ;
Wechsler, Andrew S. ;
Kaluza, Greg L. ;
Granada, Juan F. ;
Van Bladel, Kevin ;
Annest, Lon S. ;
Yi, Geng-Hua .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (06) :915-922
[8]   Polycaprolactone scaffold and reduced rhBMP-7 dose for the regeneration of critical-sized defects in sheep tibiae [J].
Cipitria, Amaia ;
Reichert, Johannes C. ;
Epari, Devakar R. ;
Saifzadeh, Siamak ;
Berner, Arne ;
Schell, Hanna ;
Mehta, Manav ;
Schuetz, Michael A. ;
Duda, Georg N. ;
Hutmacher, Dietmar W. .
BIOMATERIALS, 2013, 34 (38) :9960-9968
[9]  
Clarke KW, 2014, VET ANAESTHESIA, P345, DOI [10.1016/B978-0-7020-2793-2.00013-X, DOI 10.1016/B978-0-7020-2793-2.00013-X]
[10]   Preliminary results in anterior cervical discectomy and fusion with an experimental bioabsorbable cage - clinical and radiological findings in an ovine animal model [J].
Daentzer, Dorothea ;
Floerkemeier, Thilo ;
Bartsch, Ivonne ;
Masalha, Waseem ;
Welke, Bastian ;
Hurschler, Christof ;
Kauth, Theresa ;
Kaltbeitzel, Daniel ;
Hopmann, Christian ;
Kujat, Bernd ;
Kalla, Katharina .
SPRINGERPLUS, 2013, 2 :1-8