Experimental study on the separation performance of an enhanced cyclone with shunt device

被引:21
作者
Zheng, Yuanbo [1 ,2 ]
Li, Xinyu [3 ]
Ni, Long [1 ,2 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Harbin 150090, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Cold Reg Urban & Rural Human Settlement E, Harbin 150090, Peoples R China
[3] China NorthwestArchitecture Design & Res Inst Co, Xian 710018, Peoples R China
基金
中国国家自然科学基金;
关键词
Cyclone; Shunt device; Separation efficiency; Pressure drop; Operating parameters; DE-FOULANT HYDROCYCLONE; PRESSURE-DROP; EFFICIENCY; UNDERFLOW; MODEL;
D O I
10.1016/j.seppur.2022.120962
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To expand the application field of the cyclone, an enhanced cyclone with shunt device (ECSD) is proposed to continuously remove coarse particles from the air. To study the performance of the ECSD, an experimental bench was set up, and a series of analyses were carried out using silica particles, talc powder and light calcium powder to simulate particles in air. The effects of the split flow rate, particles (feed concentration and physical properties), feed flow rate and feed static pressure on the separation performance were investigated. The experimental results show that the separation efficiency of the ECSD is higher than that of a traditional cyclone, and continuous particle separation can be realized. With the split flow rate increasing from 0 m(3)/h to 5.2 m(3)/h, the total separation efficiency and reduced separation efficiency increase by 53% and 37%, respectively. However, the split flow rate of this model should be controlled within 5.2 m(3)/h (split ratio 45%); otherwise, the separation efficiency could not be effectively improved and the energy consumption would increase. The cut-off sizes for talc powder, light calcium powder and silica particle are approximately 3.6 mu m, 3.8 mu m and 5 mu m, respectively. For particles with sizes less than 1 mu m, the separation efficiency of the ECSD can still exceed 25%. Note that the ECSD has great potential to apply to the field where particulate matter needs to be removed.
引用
收藏
页数:10
相关论文
共 44 条
  • [1] Development of a miniature cyclone separator operating at low Reynolds numbers as a pre-separator for portable black carbon monitors
    An, Ik-Hyun
    Lee, Chang-Hoon
    Lim, Jun-Hyung
    Lee, Hyo-Young
    Yook, Se-Jin
    [J]. ADVANCED POWDER TECHNOLOGY, 2021, 32 (12) : 4779 - 4787
  • [2] Investigation into the effects of various parameters on the performance and classification potential of a cyclone classifier
    Caliskan, Mehmet Erman
    Karagoz, Irfan
    Avci, Atakan
    Surmen, Ali
    [J]. POWDER TECHNOLOGY, 2019, 356 : 102 - 111
  • [3] An experimental investigation into the particle classification capability of a novel cyclone separator
    Caliskan, Mehmet Erman
    Karagoz, Irfan
    Avci, Atakan
    Surmen, Ali
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 209 : 908 - 913
  • [4] A universal model to calculate cyclone pressure drop
    Chen, Jianyi
    Shi, Mingxian
    [J]. POWDER TECHNOLOGY, 2007, 171 (03) : 184 - 191
  • [5] A practical model for estimating pressure drop in cyclone separators: An experimental study
    Demir, Selami
    [J]. POWDER TECHNOLOGY, 2014, 268 : 329 - 338
  • [6] Effect of cylinder vortex stabilizer on separator performance of the Stairmand cyclone
    Duan, Jihai
    Gao, Shun
    Hou, Chenguang
    Wang, Weiwen
    Zhang, Pan
    Li, Chaojie
    [J]. POWDER TECHNOLOGY, 2020, 372 (372) : 305 - 316
  • [7] Performances of the BC-112 NIOSH cyclone for the measurement of endotoxins in bioaerosols: A study in laboratory conditions
    Duquenne, Philippe
    Coulais, Catherine
    Bau, Sebastien
    Simon, Xavier
    [J]. JOURNAL OF AEROSOL SCIENCE, 2018, 116 : 92 - 105
  • [8] Improving cyclone performance by proper selection of the exit pipe
    El-Batsh, Hesham M.
    [J]. APPLIED MATHEMATICAL MODELLING, 2013, 37 (07) : 5286 - 5303
  • [9] The effect of cyclone vortex finder dimensions on the flow pattern and performance using LES
    Elsayed, Khairy
    Lacor, Chris
    [J]. COMPUTERS & FLUIDS, 2013, 71 : 224 - 239
  • [10] A study of the effect of high inlet solids loading on a cyclone separator pressure drop and collection efficiency
    Fassani, FL
    Goldstein, L