Source localization determined by magnetoencephalography and electroencephalography in temporal lobe epilepsy: Comparison with electrocorticography: Technical case report

被引:41
作者
Ko, DY
Kufta, C
Scaffidi, D
Sato, S
机构
[1] NINDS, EEG Sect, NIH, Bethesda, MD 20892 USA
[2] NINDS, Epilepsy Res Branch, NIH, Bethesda, MD 20892 USA
[3] NINDS, Surg Neurol Branch, NIH, Bethesda, MD 20892 USA
关键词
brain mapping; electrocorticography; electroencephalography; epilepsy; epilepsy surgery; magnetoencephalography; seizure;
D O I
10.1097/00006123-199802000-00142
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE AND IMPORTANCE: Source modeling by magnetoencephalography (MEG) and electroencephalography (EEG) may be useful techniques for noninvasive localization of epileptogenic zones for surgery in patients with partial seizures. CLINICAL PRESENTATION: Simultaneous recordings of MEG and EEC, obtained in two patients, were coregistered on each patient's magnetic resonance image for direct comparison of these two methods with intracranial electrocorticography, TECHNIQUE: The average difference between MEG and EEG for localization of the same interictal spikes was approximately 2 cm in one patient and 3.8 cm in the other patient. One patient experienced a complex partial seizure during testing, which permitted comparison between interictal and ictal source localization by both MEG and EEG, The EEG ictal localization differed from the interictal one, whereas the MEG ictal and interictal localizations were more similar. In this patient, the MEG interictal source seemed to localize close to the ictal source, whereas EEG did not. The patients underwent temporal lobectomy after electrocorticography, and the results were compared with the findings of MEG and EEG. Although the results of both techniques agreed with the findings of electrocorticography, in one patient the MEG localization seemed to be more accurate. Both patients experienced good surgical outcomes. CONCLUSION: Both MEG and EEC source localization can add useful and complementary information for epilepsy surgery evaluation, MEG seemed to be more accurate than EEG, especially when comparing interictal versus ictal localization. Further study is needed to evaluate the validity of source localization as useful noninvasive techniques to localize the epileptogenic zone.
引用
收藏
页码:414 / 421
页数:8
相关论文
共 22 条
  • [1] LOCALIZATION OF IMPLANTED DIPOLES BY MAGNETOENCEPHALOGRAPHY
    BALISH, M
    SATO, S
    CONNAUGHTON, P
    KUFTA, C
    [J]. NEUROLOGY, 1991, 41 (07) : 1072 - 1076
  • [2] NEUROMAGNETIC LOCALIZATION OF EPILEPTIFORM SPIKE ACTIVITY IN THE HUMAN-BRAIN
    BARTH, DS
    SUTHERLING, W
    ENGEL, J
    BEATTY, J
    [J]. SCIENCE, 1982, 218 (4575) : 891 - 894
  • [3] PRESURGICAL EVALUATION OF TEMPORAL-LOBE EPILEPSY USING INTERICTAL TEMPORAL SPIKES AND POSITRON EMISSION TOMOGRAPHY
    CHEE, MWL
    MORRIS, HH
    ANTAR, MA
    VANNESS, PC
    DINNER, DS
    REHM, P
    SALANOVA, V
    [J]. ARCHIVES OF NEUROLOGY, 1993, 50 (01) : 45 - 48
  • [4] MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN
    COHEN, D
    CUFFIN, BN
    YUNOKUCHI, K
    MANIEWSKI, R
    PURCELL, C
    COSGROVE, GR
    IVES, J
    KENNEDY, JG
    SCHOMER, DL
    [J]. ANNALS OF NEUROLOGY, 1990, 28 (06) : 811 - 817
  • [5] CUFFIN BN, 1979, ELECTROEN CLIN NEURO, V47, P132, DOI 10.1016/0013-4694(79)90215-3
  • [6] STATUS EPILEPTICUS INDUCED BY FELBATOL WITHDRAWAL
    DEGIORGIO, CM
    LOPEZ, JE
    LEKHT, ZN
    RABINOWICZ, AL
    [J]. NEUROLOGY, 1995, 45 (05) : 1021 - 1022
  • [7] EBERSOLE J S, 1991, Brain Topography, V4, P113, DOI 10.1007/BF01132768
  • [8] GEVINS AS, 1988, FUNCTIONAL BRAIN IMAGING, P99
  • [9] MAGNETOENCEPHALOGRAPHY - THEORY, INSTRUMENTATION, AND APPLICATIONS TO NONINVASIVE STUDIES OF THE WORKING HUMAN BRAIN
    HAMALAINEN, M
    HARI, R
    ILMONIEMI, RJ
    KNUUTILA, J
    LOUNASMAA, OV
    [J]. REVIEWS OF MODERN PHYSICS, 1993, 65 (02) : 413 - 497
  • [10] MEG VERSUS EEG LOCALIZATION TEST
    HARI, R
    HAMALAINEN, M
    ILMONIEMI, R
    LOUNASMAA, OV
    [J]. ANNALS OF NEUROLOGY, 1991, 30 (02) : 222 - 223