Detection of simulated chest lesions with normal and reduced radiation dose -: Comparison of conventional screen-film radiography and a flat-panel x-ray detector based on amorphous silicon

被引:58
作者
Strotzer, M [1 ]
Gmeinwieser, JK [1 ]
Völk, M [1 ]
Fründ, R [1 ]
Seitz, J [1 ]
Feuerbach, S [1 ]
机构
[1] Univ Hosp Regensburg, Dept Diagnost Radiol, D-93042 Regensburg, Germany
关键词
radiography; digital; amorphous silicon; receiver operating characteristic curve;
D O I
10.1097/00004424-199802000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors compared a solid-state amorphous silicon (a-Si) detector and screen-film radiography (SFR) with regard to the detection of simulated pulmonary lesions. Evaluation of the impact of a dose reduction of 50% with this digital flat-panel detector was of special interest. METHODS. A self-scanning flat-panel detector, based on a-Si technology with 143 x 143 mu m pixel size, 1 k x 1 k matrix and 12-bit digital output was used. An asymmetric state-of-the-art screen-film system was compared with a-Si images taken at the same dose as SFR-images and at a dose reduced by 50%. An anthropomorphic chest phantom was superimposed by templates containing nodules, linear structures, reticular, and micronodular opacities in a random distribution. Receiver operating characteristic analysis was performed for 23,040 observations made by four independent observers. Student's t test (95% confidence-level) was used for statistical analysis. RESULTS. Receiver operating characteristic analysis showed that a-Si images taken at the same dose as SFR-images were significantly superior to SFR with respect to the detectability of lines (P = 0.01) and micronodular opacities (P < 0.01). For the other objects and the a-Si images taken at a reduced dose, it yielded no statistically significant differences between both imaging modalities. CONCLUSIONS. The results of this phantom study indicate that a-Si detector technology holds promise in terms of dose reduction in chest radiography without loss of diagnostic accuracy compared with SFR.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 24 条
  • [21] Detection of simulated chest lesions by using soft-copy reading: Comparison of an amorphous silicon flat-panel-detector system and a storage-phosphor system
    Goo, JM
    Im, JG
    Lee, HJ
    Chung, MJ
    Seo, JB
    Kim, HY
    Lee, YJ
    Kang, JW
    Kim, JH
    RADIOLOGY, 2002, 224 (01) : 242 - 246
  • [22] Amorphous silicon, flat-panel, X-ray detector versus storage phosphor-based computed radiography:: Contrast-detail phantom study at different tube voltages and detector entrance doses
    Hamer, OW
    Völk, M
    Zorger, N
    Feuerbach, S
    Strotzer, M
    INVESTIGATIVE RADIOLOGY, 2003, 38 (04) : 212 - 220
  • [23] Dual energy chest x-ray for improved COVID-19 detection using a dual-layer flat-panel detector: Simulation and phantom studies
    Shi, Linxi
    Bennett, N. Robert
    Lu, Minghui
    Sun, Mingshan
    Zhang, Jin
    Star-Lack, Josh
    Tsai, Emily B.
    Guo, H. Henry
    Wang, Adam S.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [24] Difference in diaphragmatic motion during tidal breathing in a standing position between COPD patients and normal subjects: Time-resolved quantitative evaluation using dynamic chest radiography with flat panel detector system ("dynamic X-ray phrenicography")
    Yamada, Yoshitake
    Ueyama, Masako
    Abe, Takehiko
    Araki, Tetsuro
    Abe, Takayuki
    Nishino, Mizuki
    Jinzaki, Masahiro
    Hatabu, Hiroto
    Kudoh, Shoji
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 76 - 82