Frequency Stability Constrained Optimal Power Flow Incorporating Differential Algebraic Equations of Governor Dynamics

被引:40
作者
Zhao, Xiaohui [1 ]
Wei, Hua [1 ]
Qi, Junjian [2 ]
Li, Peijie [1 ]
Bai, Xiaoqing [1 ]
机构
[1] Guangxi Univ, Sch Elect Engn, Nanning 530004, Peoples R China
[2] Stevens Inst Technol, Dept Elect & Comp Engn, Hoboken, NJ 07030 USA
基金
中国国家自然科学基金;
关键词
Frequency control; Mathematical model; Power system stability; Frequency response; Power system dynamics; Stability criteria; Differential algebraic equations (DAEs); frequency stability; optimal power flow (OPF); primary frequency response; primary reserve; METHODOLOGY; OPF;
D O I
10.1109/TPWRS.2020.3025335
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency dynamics during primary frequency control is closely related to pre-disturbance operating conditions, the disturbance, and equipment characteristics. How to rigorously express such a relation in a frequency stability constrained optimal dispatch problem is still an open question. This paper presents an optimal power flow (OPF) model for generation re-dispatch that considers dynamic frequency response constraints to ensure frequency stability during primary frequency regulation. The distinct feature of the model is that the dynamic frequency response is formulated as a set of differential algebraic equations (DAEs), which allows considering the transient behavior of frequency and mechanical/electromagnetic power for each generator during primary frequency control period. Based on the solution of the optimization problem, a definition of the primary reserve for each unit is proposed according to the maximum of incremental mechanical power. This definition helps meet the adequacy requirement of primary frequency response and achieve partial frequency restoration. Simulation results on WSCC 3-machine 9-bus system, New England 10-machine 39-bus system and the modified IEEE 54-machine 118-bus system validate the effectiveness of the proposed model and reveal the strong coupling between frequency dynamics and the pre-disturbance generation.
引用
收藏
页码:1666 / 1676
页数:11
相关论文
共 30 条
[1]  
[Anonymous], 2015, IEEE 118 BUS MOD TES
[2]  
[Anonymous], 2014, tech. rep.
[3]  
[Anonymous], 2013, OXID MED CELL LONGEV, DOI DOI 10.1155/2013/146860
[4]  
[Anonymous], IEEE 9 BUS MOD TEST
[5]  
[Anonymous], 2000, POW SYST TEST CAAR
[6]   Semidefinite programming for optimal power flow problems [J].
Bai, Xiaoqing ;
Wei, Hua ;
Fujisawa, Katsuki ;
Wang, Yong .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2008, 30 (6-7) :383-392
[7]   Advanced optimization strategies for integrated dynamic process operations [J].
Biegler, Lorenz T. .
COMPUTERS & CHEMICAL ENGINEERING, 2018, 114 :3-13
[8]   Governor Rate-Constrained OPF for Primary Frequency Control Adequacy [J].
Chavez, Hector ;
Baldick, Ross ;
Sharma, Sandip .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (03) :1473-1480
[9]   BOILER MODELS FOR SYSTEM DYNAMIC PERFORMANCE STUDIES [J].
DEMELLO, FP .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1991, 6 (01) :66-74
[10]   Dynamic IEEE Test Systems for Transient Analysis [J].
Demetriou, Panayiotis ;
Asprou, Markos ;
Quiros-Tortos, Jairo ;
Kyriakides, Elias .
IEEE SYSTEMS JOURNAL, 2017, 11 (04) :2108-2117