Monitoring renal function: A prospective study comparing camera-based technetium-99m mercaptoacetyltriglycine clearance and creatinine clearance

被引:15
作者
Halkar, Raghuveer
Taylor, Andrew
Manatunga, Amita
Issa, Muta M.
Myrick, Samuel E.
Grant, Sandra
Shenvi, Neeta V.
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Biostat, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Dept Urol, Atlanta, GA 30322 USA
[4] Vet Affairs Med Ctr, Atlanta, GA 30033 USA
关键词
D O I
10.1016/j.urology.2006.11.026
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES To determine the value and limitations of technetium-99m mercaptoacetyltriglycine (MAG3) clearance measurements obtained using a gamma camera (camera-based MAG3 clearance), a prospective study was conducted to evaluate the reproducibility of camera-based MAG3 clearance compared with that of conventional creatinine clearance. METHODS A total of 24 male patients with stable renal function were entered into the study. The mean age was 66.5 +/- 7.9 years, and the mean serum creatinine was 1.38 +/- 0.57 mg/dL. MAG3 renal scans and 24-hour creatinine clearance measurements were performed 11 +/- 8 days apart. A camera-based MAG3 clearance was obtained at each MAG3 scan; no blood samples were required. Bland-Altman plots were constructed to assist in data analysis. RESULTS The Pearson correlation for the first and second camera-based MAG3 clearances (mean 151 versus 158 mL/min/1.73 m(2), respectively) was 0.965 compared with 0.729 for the two creatinine clearance measurements (mean 62 versus 72 mL/min/1.73 m(2), respectively). Even with the omission of two outliers, the creatinine clearance would have to change by 58.2% compared with the baseline measurement before the clinician could be confident the change exceeded the error of measurement. In contrast, the change required for the camera-based MAG3 clearance was 30.8%. CONCLUSIONS The results of this study have demonstrated that MAG3 clearance obtained using a camera-based technique shows greater precision than the conventional creatinine clearance and is superior to the conventional creatinine clearance for monitoring changes in renal function.
引用
收藏
页码:426 / 430
页数:5
相关论文
共 20 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Blaufox MD, 1996, J NUCL MED, V37, P1883
[3]   SELECTION OF ROUTINE METHOD FOR DETERMINATION OF GLOMERULAR-FILTRATION RATE IN ADULT PATIENTS [J].
BROCHNERMORTENSEN, J ;
RODBRO, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (01) :35-43
[4]   TC-99M (TC-99M) MERCAPTOACETYLTRIGLYCINE - UPDATE ON THE NEW TC-99M RENAL TUBULAR FUNCTION AGENT [J].
ESHIMA, D ;
TAYLOR, A .
SEMINARS IN NUCLEAR MEDICINE, 1992, 22 (02) :61-73
[5]  
Esteves Fabio P, 2006, AJR Am J Roentgenol, V187, pW610, DOI 10.2214/AJR.05.1550
[6]  
ESTEVES FP, 2006, AM J ROENTGENOL, V187, pW1
[8]  
Itoh K, 1996, J NUCL MED, V37, P71
[9]   Reproducibility of 99Tcm-MAG3 clearance in normal volunteers with the two-sample method:: Comparison with 131I-OIH [J].
Kanazawa, T ;
Shimizu, M ;
Seto, H ;
Kageyama, M ;
Kameda, K ;
Toyoshima, S ;
Tomizawa, G ;
Watanabe, N ;
Inagaki, S .
NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (09) :899-903
[10]  
KLINGENSMITH WC, 1994, J NUCL MED, V35, P1612