Molecularly imprinted polymers as antibody mimics in automated on-line fluorescent competitive assays

被引:79
作者
Urraca, Javier L.
Moreno-Bondi, Maria C. [1 ]
Orellana, Guillermo
Sellergren, Borje
Hall, Andrew J.
机构
[1] Univ Complutense Madrid, Dept Analyt Chem, Fac Chem, E-28040 Madrid, Spain
[2] Univ Complutense Madrid, Dept Organ Chem, Fac Chem, E-28040 Madrid, Spain
[3] Univ Dortmund, Inst Umweltforsch, D-44221 Dortmund, Germany
[4] Univ Sunderland, Inst Pharm Chem & Biomed Sci, Sunderland SR1 3SD, England
关键词
D O I
10.1021/ac070277i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated molecularly imprinted sorbent based assay (MIA) for the rapid and sensitive analysis of penicillin-type beta-lactam antibiotics (BLAs) has been developed and optimized. The polymers were prepared using penicillin G procaine salt as template (PENGp) and a stoichiometric quantity of a urea-based functional monomer to target the single oxyanionic species in the template molecule. Highly fluorescent competitors (emission quantum yields of 0.4-0.95), molecularly engineered to contain pyrene labels while keeping intact the 6-aminopenicillanic acid moiety for efficient recognition by the cross-linked polymers, have been tested as analyte analogues in the competitive assay. Pyrenemethylacetamido penicillanic acid (PAAP) was the tagged antibiotic providing for the highest selectivity when competing with PenG for the specific binding sites in the molecularly imprinted polymer (MIP). Upon desorption from the MIP, the emission signal generated by the PAAP was related to the antibiotic concentration in the sample. The 50% binding inhibition concentration of penicillin G standard curves was at 1.81 x 10(-6) M PENG, and the detection limit was 1.97 x 10(-7) M. The sensor showed a dynamic range (normalized signal in the 20 to 80% range) from 6.80 x 10(-7) to 7.21 x 10(-6) M (20-80% binding inhibition) PENG in acetonitrile:HEPES buffer 0.1 M at pH 7.5 (40:60, v/v) solutions. Competitive binding studies demonstrated various degrees of cross-reactivity with penicillin-type beta-lactam antibiotics such as ampicillin (71%), oxacillin (66%), penicillin V (56%), amoxicillin (13%), and nafcillin (46%) and a lower response to other isoxazolyl penicillins such as cloxacillin (27%) and dicloxacillin (16%). The total analysis time was 14 min per determination, and the MIP reactor could be reused for more than 150 cycles without significant loss of recognition. The automatic MIA has been successfully applied to the direct analysis of penicillin G in spiked urine samples with excellent recoveries (mean value 92%). Results displayed by comparative analysis of the optimized MIA with a chromatographic procedure for penicillin G showed excellent agreement between both methods.
引用
收藏
页码:4915 / 4923
页数:9
相关论文
共 24 条
[1]   Molecular imprinting science and technology: a survey of the literature for the years up to and including 2003 [J].
Alexander, C ;
Andersson, HS ;
Andersson, LI ;
Ansell, RJ ;
Kirsch, N ;
Nicholls, IA ;
O'Mahony, J ;
Whitcombe, MJ .
JOURNAL OF MOLECULAR RECOGNITION, 2006, 19 (02) :106-180
[2]   Molecular imprinting for drug bioanalysis - A review on the application of imprinted polymers to solid-phase extraction and binding assay [J].
Andersson, LI .
JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (01) :163-173
[3]   Molecularly imprinted polymers in pseudoimmunoassay [J].
Ansell, RJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01) :151-165
[4]   Molecular engineering of fluorescent penicillins for molecularly imprinted polymer assays [J].
Benito-Peña, E ;
Moreno-Bondi, MC ;
Aparicio, S ;
Orellana, G ;
Cederfur, J ;
Kempe, M .
ANALYTICAL CHEMISTRY, 2006, 78 (06) :2019-2027
[5]   Development of a novel and automated fluorescent immunoassay for the analysis of β-lactam antibiotics [J].
Benito-Peña, E ;
Moreno-Bondi, MC ;
Orellana, G ;
Maquieira, K ;
Van Amerongen, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (17) :6635-6642
[6]   On-line immunoanalysis for environmental pollutants:: from batch assays to automated sensors [J].
González-Martínez, MA ;
Puchades, R ;
Maquieira, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) :204-218
[7]   Colorimetric molecularly imprinted polymer sensor array using dye displacement [J].
Greene, NT ;
Shimizu, KD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (15) :5695-5700
[8]   Urea host monomers for stoichiometric molecular imprinting of oxyanions [J].
Hall, AJ ;
Manesiotis, P ;
Emgenbroich, M ;
Quaglia, M ;
De Lorenzi, E ;
Sellergren, B .
JOURNAL OF ORGANIC CHEMISTRY, 2005, 70 (05) :1732-1736
[9]   Herbicide assay using an imprinted polymer based system analogous to competitive fluoroimmunoassays [J].
Haupt, K ;
Mayes, AG ;
Mosbach, K .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3936-3939
[10]   A fluorescence polarisation molecular imprint sorbent assay for 2,4-D: a non-separation pseudo-immunoassay [J].
Hunt, CE ;
Pasetto, P ;
Ansell, RJ ;
Haupt, K .
CHEMICAL COMMUNICATIONS, 2006, (16) :1754-1756