The cushion scanning technique: A method of dynamic tongue sonography and its comparison with the transducer-skin coupling scanning technique during swallowing

被引:20
作者
Peng, CL [1 ]
JostBrinkmann, PG [1 ]
Miethke, RR [1 ]
机构
[1] UNIV HOSP CHARITE,CTR DENT,DEPT ORTHODONT & DENTOFACIAL ORTHOPED,BERLIN,GERMANY
关键词
sonography; swallowing; cushion scanning technique; tongue function;
D O I
10.1016/S1076-6332(96)80449-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We describe the cushion scanning technique (CST), which solves common difficulties encountered during ultrasound investigations of swallowing. These problems arise when the transducer is held in direct contact with the submental area. Some of these problems include movements of the ultrasound transducer during swallowing and compression of the submental region, which causes abnormal swallowing patterns. Methods. To compare ultrasound images produced with the conventional hand-held transducer-skin coupling scanning technique with the CST, we studied five participants with no clinical signs of tongue dysfunction. All tongue movements were recorded by real-time B+M-mode sonography. Results. Images produced with the hand-held transducer were found to be unstable because the transducer moved during swallowing, thereby changing the scanning section. By contrast, the transducer and the participant's head remained in a constant position throughout the CST trial. There was no obvious compression of the submental muscles. Conclusion. The CST allows for a better intraindividual reproducibility of the swallowing pattern and for a more standardized and objective ultrasound examination than the hand-held transducer-skin coupling scanning technique.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 16 条
  • [1] EKBERG O, 1986, Acta Radiologica Diagnosis, V27, P533
  • [2] Fuhrmann R, 1993, Fortschr Kieferorthop, V54, P17, DOI 10.1007/BF02168015
  • [3] Fuhrmann R, 1992, DTSCH ZAHNARZTL Z, V47, P586
  • [4] CHARACTERIZATION OF TONGUE SHAPE
    MORRISH, KA
    STONE, M
    SONIES, BC
    KURTZ, D
    SHAWKER, T
    [J]. ULTRASONIC IMAGING, 1984, 6 (01) : 37 - 47
  • [5] Mussig D, 1992, Fortschr Kieferorthop, V53, P338, DOI 10.1007/BF02311850
  • [6] Peng C L, 1994, Fortschr Kieferorthop, V55, P209, DOI 10.1007/BF02173752
  • [7] PENG CL, 1994, EUR J ORTHODONT, V16, P345
  • [8] RAKOSI T, 1970, Fortschritte der Kieferorthopaedie, V31, P81, DOI 10.1007/BF02024853
  • [9] USE OF ELECTROMAGNETIC-FIELDS FOR TRACKING MOVEMENTS OF MULTIPLE POINTS INSIDE AND OUTSIDE THE VOCAL-TRACT
    SCHONLE, PW
    WENIG, P
    SCHRADER, J
    GRABE, K
    BROCKMANN, E
    CONRAD, B
    [J]. BIOMEDIZINISCHE TECHNIK, 1983, 28 (11): : 263 - 267
  • [10] Schwestka-Polly P, 1992, FORTSCHR KIEFERORTHO, V53, P3