Mechanical properties of zirconia after different surface treatments and repeated firings

被引:41
作者
Subasi, Meryem Gulce [1 ]
Demir, Necla [2 ]
Kara, Ozlem [3 ]
Ozturk, A. Nilgun [2 ]
Ozel, Faruk [4 ]
机构
[1] Istanbul Aydin Univ, Dept Prosthodont, Fac Dent, TR-34295 Istanbul, Turkey
[2] Selcuk Univ, Dept Prosthodont, Fac Dent, Konya, Turkey
[3] Bezmialem Vakif Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey
[4] Selcuk Univ, Dept Chem Engn, Fac Engn, Konya, Turkey
关键词
Surface treatment; Zirconium oxide; Ceramics; X-ray diffraction; Flexural strength; Y-TZP-ZIRCONIA; BIAXIAL FLEXURAL STRENGTH; PHASE-TRANSFORMATION; DENTAL CERAMICS; HEAT-TREATMENT; FRACTURE-TOUGHNESS; RELIABILITY; MICROSTRUCTURE; 3Y-TZP;
D O I
10.4047/jap.2014.6.6.462
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study investigated the influence of surface conditioning procedures and repeated firings on monoclinic content and strength of zirconia before cementation. MATERIALS AND METHODS. Sintered bar-shaped zirconia specimens were subjected to no surface treatment (control), air abrasion, Or grinding (n=21). Their roughness was evaluated using a profilometer, and microscope analysis was performed on one specimen of each group. Then, 2 or 10 repeated firings (n=10) were executed, the monoclinic content of specimens was analyzed by X-ray diffraction, and a three-point flexural strength test was performed. Surface roughness values were compared using one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests, the monoclinic content values were tested using Kruskal-Wallis and Mahn-Whitney U tests, and the flexural strength values were tested using two-way ANOVA and Tukey HSD tests (P=.05). Spearman's correlation test was performed to define relationships among measured parameters. RESULTS. Surface-treated specimens were rougher than untreated specimens and had a higher monoclinic content (P<.005), and the relationship between roughness and monoclinic content was significant (P<.000). Neither surface treatment nor firing significantly affected the flexural strength, but Weibull analysis showed that for the air-abraded samples the characteristic strength was significantly. lower after the 10th firing than after. the 2nd firing. CONCLUSION. After firing, a negligible amount of monoclinic content remained on the zirconia surfaces, and rougher surfaces had higher monoclinic contents than untreated surfaces. Multiple firings Could be performed if necessary, but the fracture probability could increase after multiple firings for rougher surfaces.
引用
收藏
页码:462 / 467
页数:6
相关论文
共 41 条
[1]  
Bona Alvaro Della, 2003, Dent Mater, V19, P662
[2]   Influence of hydrothermal and mechanical conditions on the strength of zirconia [J].
Borchers, Lothar ;
Stiesch, Meike ;
Bach, Friedrich-Wilhelm ;
Buhl, Josef-Christian ;
Huebsch, Christoph ;
Kellner, Tim ;
Kohorst, Philipp ;
Jendras, Michael .
ACTA BIOMATERIALIA, 2010, 6 (12) :4547-4552
[3]   The influence of simulated masticatory loading regimes on the bi-axial flexure strength and reliability of a Y-TZP dental ceramic [J].
Curtis, Andrew R. ;
Wright, Adrian J. ;
Fleming, Garry J. P. .
JOURNAL OF DENTISTRY, 2006, 34 (05) :317-325
[4]   The influence of surface modification techniques on the performance of a Y-TZP dental ceramic [J].
Curtis, AR ;
Wright, AJ ;
Fleming, GJP .
JOURNAL OF DENTISTRY, 2006, 34 (03) :195-206
[5]   Effect of heat treatment after accelerated aging on phase transformation in 3Y-TZP [J].
Denry, I. L. ;
Peacock, J. J. ;
Holloway, J. A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 93B (01) :236-243
[6]   Microstructural and crystallographic surface changes after grinding zirconia-based dental ceramics [J].
Denry, IL ;
Holloway, JA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 76B (02) :440-448
[7]  
Denry IL, 1999, J BIOMED MATER RES, V48, P791, DOI 10.1002/(SICI)1097-4636(1999)48:6<791::AID-JBM5>3.0.CO
[8]  
2-P
[9]   State of the art of zirconia for dental applications [J].
Denry, Isabelle ;
Kelly, J. Robert .
DENTAL MATERIALS, 2008, 24 (03) :299-307
[10]   Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia [J].
Deville, S ;
Chevalier, J ;
Gremillard, L .
BIOMATERIALS, 2006, 27 (10) :2186-2192