Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena

被引:2
作者
Sankaranarayanan, A. [1 ]
Sankarlal, K. M. Prabu [2 ]
Raja, D. [1 ]
机构
[1] KS Rangasamy Coll Arts & Sci, Dept Microbiol, Tiruchengode, Tamil Nadu, India
[2] KS Rangasamy Coll Arts & Sci, Dept Elect & Commun, Tiruchengode, Tamil Nadu, India
关键词
water borne pathogens; drinking water; frequency; dielectrophoretic phenomena; BIOLOGICAL CELLS; MICROBES; FLOW;
D O I
10.3103/S1063455X16020107
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The article has investigated the removal of water borne pathogens using dielectrophoresis (DEP) filter which is energized by varying the frequency of the applied potential from 10 kHz to 2 MHz with different voltage levels of 5; 10; 15 and 20 V. Separate experiments are conducted in artificially contaminated water samples with Escherichia coli, Staphylococcus aureus and Vibrio cholerae up to 2 h. The impact of signal frequency and voltages on DEP based water treatment system has been analyzed statistically. Results have demonstrated that an AC signal of 20 V with frequency range of 500 kHz to 2 MHz is suitable to remove the tested bacterial population and the rate of removal of E. coli is the highest with a dielectrophoretic filtration efficiency of 77.1%.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 16 条
[1]   Separating microbes in the manner of molecules. 1. Capillary electrokinetic approaches [J].
Armstrong, DW ;
Schulte, G ;
Schneiderheinze, JM ;
Westenberg, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (24) :5465-5469
[2]   Dielectrophoretic analysis of microbes in water [J].
Betts, WB ;
Brown, AP .
JOURNAL OF APPLIED MICROBIOLOGY, 1999, 85 :201S-213S
[3]  
BETTS WB, 1995, TRENDS FOOD SCI TECH, V6, P51, DOI 10.1016/S0924-2244(00)88943-8
[4]   Evaluation of a dielectrophoretic bacterial counting technique [J].
Brown, AP ;
Betts, WB ;
Harrison, AB ;
O'Neill, JG .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (03) :341-351
[5]   Dielectrophoresis in microchips containing arrays of insulating posts: Theoretical and experimental results [J].
Cummings, EB ;
Singh, AK .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4724-4731
[6]   Rapid Concentration of Nanoparticles with DC Dielectrophoresis in Focused Electric Fields [J].
Chen, Dafeng ;
Du, Hejun ;
Tay, Chee Yong .
NANOSCALE RESEARCH LETTERS, 2010, 5 (01) :55-60
[7]  
Fan X., 2008, J GASTROEN HEPATOL, V13, P1096
[8]  
Foong L. P., 2009, ELECTROPHORETI UNPUB
[9]   Aligning fast alternating current electroosmotic flow fields and characteristic frequencies with dielectrophoretic traps to achieve rapid bacteria detection [J].
Gagnon, Z ;
Chang, HC .
ELECTROPHORESIS, 2005, 26 (19) :3725-3737
[10]   Electrothermally induced fluid flow on microelectrodes [J].
Green, NG ;
Ramos, A ;
González, A ;
Castellanos, A ;
Morgan, H .
JOURNAL OF ELECTROSTATICS, 2001, 53 (02) :71-87