Comparison of the anterior capsulotomy edge created by manual capsulorhexis and 2 femtosecond laser platforms: Scanning electron microscopy study

被引:24
作者
Al Harthi, Khaled [1 ]
Al Shahwan, Sami [1 ]
Al Towerki, Abdulelah [1 ]
Banerjee, P. Pat [2 ]
Behrens, Ashley [1 ,3 ]
Edward, Deepak P. [1 ,3 ]
机构
[1] King Khalid Eye Specialist Hosp, Riyadh 11462, Saudi Arabia
[2] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL USA
[3] Johns Hopkins Univ, Wilmer Eye Inst, Baltimore, MD 21218 USA
关键词
INTRAOCULAR-LENS DISLOCATION; ASSISTED CATARACT-SURGERY; IN-THE-BAG; INTERFACE;
D O I
10.1016/j.jcrs.2014.10.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the scanning electron microscopy (SEM) features of the anterior capsule edge created by continuous curvilinear capsulorhexis (CCC) and femtosecond laser-assisted capsulotomy using angular second moment and contrast. SETTING: King Khaled Eye Specialist Hospital, Riyadh, Kingdom of Saudi Arabia. DESIGN: Prospective comparative series. METHODS: Anterior capsule specimens following CCC (n = 10) or femtosecond laser-assisted capsulotomy using 2 platforms (Lensx, n = 9, and Victus, n = 10) were studied by SEM. Irregularity of the capsule edge was quantified using 2 parameters (angular second moment and contrast) using ImageJ software. The clinical features and laser parameters were correlated with angular second moment and contrast. RESULTS: By SEM, the femtosecond laser-assisted capsulotomy edge surfaces created by both lasers showed marked irregularity compared with the smooth edge of the CCC. The angular second moment and contrast measures for both lasers differed significantly from those obtained for CCC (P<.001). There was no between-laser difference in angular second moment and contrast measures. The angular second moment showed only a weak negative correlation with increasing laser power, whereas contrast showed a weak positive correlation with increasing power. CONCLUSIONS: Both laser platforms created an irregular capsulotonny edge. The angular second moment and contrast quantified capsule edge irregularities for further comparisons. These measures could be used to quantify efforts to reduce capsule-edge irregularity from femtosecond laser-lens capsule interaction.
引用
收藏
页码:2106 / 2112
页数:7
相关论文
共 24 条
  • [1] Anterior Capsulotomy Integrity after Femtosecond Laser-Assisted Cataract Surgery
    Abell, Robin G.
    Davies, Peter E. J.
    Phelan, David
    Goemann, Karsten
    McPherson, Zachary E.
    Vote, Brendan J.
    [J]. OPHTHALMOLOGY, 2014, 121 (01) : 17 - 24
  • [2] Burger W., 2008, DIGITAL IMAGE PROCES
  • [3] Femtosecond laser-assisted cataract surgery
    Donaldson, Kendall E.
    Braga-Mele, Rosa
    Cabot, Florence
    Davidson, Richard
    Dhaliwal, Deepinder K.
    Hamilton, Rex
    Jackson, Mitchell
    Patterson, Larry
    Stonecipher, Karl
    Yoo, Sonia H.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (11) : 1753 - 1763
  • [4] Subjective difficulty of each stage of phacoemulsification cataract surgery performed by basic surgical trainees
    Dooley, IJ
    O'Brien, PD
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (04) : 604 - 608
  • [5] Femtosecond laser capsulotomy
    Friedman, Neil J.
    Palanker, Daniel V.
    Schuele, Georg
    Andersen, Dan
    Marcellino, George
    Seibel, Barry S.
    Battle, Juan
    Feliz, Rafael
    Talamo, Jonathan H.
    Blumenkranz, Mark S.
    Culbertson, William W.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07) : 1189 - 1198
  • [6] DEVELOPMENT, ADVANTAGES, AND METHODS OF THE CONTINUOUS CIRCULAR CAPSULORHEXIS TECHNIQUE
    GIMBEL, HV
    NEUHANN, T
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) : 31 - 37
  • [7] CONTINUOUS CURVILINEAR CAPSULORHEXIS
    GIMBEL, HV
    NEUHANN, T
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01) : 110 - 111
  • [8] Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome
    Hayashi, H
    Hayashi, K
    Nakao, F
    Hayashi, F
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (12) : 1429 - 1432
  • [9] Possible predisposing factors for in-the-bag and out-of-the-bag intraocular lens dislocation and outcomes of intraocular lens exchange surgery
    Hayashi, Ken
    Hirata, Akira
    Hayashi, Hideyuki
    [J]. OPHTHALMOLOGY, 2007, 114 (05) : 969 - 975
  • [10] Scanning electron microscopic characteristics of lamellar keratotomies using the Femtec femtosecond laser and the Zyoptix XP microkeratome. A comparison of quality
    Heichel, J.
    Hammer, T.
    Sietmann, R.
    Duncker, G. I. W.
    Wilhelm, F.
    [J]. OPHTHALMOLOGE, 2010, 107 (04): : 333 - 340